SOLID-STATE FREQUENCY CONVERTER 400 HERTZ, 3-PHASE OUTPUT

1989-09-01
HISTORICAL
ARP1940
This specification covers the requirements for solid-state frequency converters with 480 [or 380] V 3-phase, 60 [or 50] Hz input and 115/200 V, 3-phase, 400 Hz output capable of powering aircraft type loads requiring MIL-STD-704D quality power. The frequency converter shall be a self-contained unit suitable for the environment of intended use. Typical applications include dedicated use at passenger loading bridges (mounted under the bridge in telescoping bridge applications or fixed installation at base of stationary type loading bridges) with weatherproof enclosures or hangar/lab use where indoor fixed or portable units can be used.
Standard

EFFECTS OF NO-BREAK POWER TRANSFER ON 400 HZ AUXILIARY-POWER UNITS AND GROUND-POWER UNITS

1992-02-01
CURRENT
AIR4651
This SAE Aerospace Information Report (AIR) describes the characteristics and effects of using no-break power transfer (NBPT) methods when switching between auxiliary-power unit (APU) and ground-power unit (GPU). The GPU may be: a Point-of-use solid-state frequency converter, engine-generator, or motor-generator b Central system powered by motor-generator or solid-state frequency converter
Standard

Airport Electrical Power System Harmonics

2020-09-23
CURRENT
AIR5387
This SAE Aerospace Information Report (AIR) is intended to cover all airport 50 or 60 Hz electrical systems as well as all electrical utilization equipment that is attached to those systems.
Standard

400-CYCLE GROUND POWER UNIT PROVISIONS FOR AIRCRAFT ELECTRICAL SYSTEM PROTECTION

2002-12-16
CURRENT
ARP760
This SAE Recommended Practice which defines the terms and tabulates the limits of the characteristics for various protective devices used in conjunction with 400-cycle ground power for civil aircraft is intended to assist the airlines in standardizing on 400-cycle protective systems. The limits found to be acceptable in the civil aircraft industry are presented.
Standard

MAINTENANCE OF BATTERIES AND BATTERY CHARGING AND SERVICING FACILITIES

1992-06-10
HISTORICAL
AIR1898
This SAE Aerospace Information Report (AIR) covers, and is restricted to, hands-on servicing/maintenance of industrial lead acid batteries used solely for motive power and exclusively for ground support equipment (GSE). It does not address or pertain to automotive-type SLI (starting-lighting-ignition) batteries or any other types of batteries (such as nickel-cadmium, zinc, or lithium batteries) which may be on-board airport GSE for either motive power or auxiliary uses. Similarly, the battery servicing and charging facilities described herein are those intended exclusively for industrial lead acid batteries.
Standard

Maintenance of Batteries and Battery Charging and Servicing Facilities

2020-09-23
CURRENT
AIR1898A
This SAE Aerospace Information Report (AIR) covers, and is restricted to, hands-on servicing/ maintenance of industrial lead acid batteries used solely for motive power and exclusively for ground support equipment (GSE). It does not address or pertain to automotive-type SLI (starting-lighting-ignition) batteries or any other types of batteries (such as nickel-cadmium, zinc, or lithium batteries) which may be on-board airport GSE for either motive power or auxiliary uses. Similarly, the battery servicing and charging facilities described herein are those intended exclusively for industrial lead acid batteries.
Standard

AIRCRAFT DAMAGE CAUSED BY GROUND SUPPORT EQUIPMENT

1992-12-01
HISTORICAL
AIR1589
This AIR examines only those incidents which were caused by ground support equipment used for aircraft handling and servicing and for line maintenance. It does not include damage that occurred during heavy maintenance or overhaul activity, taxi incidents or accidents where an aircraft under tow collided with a piece of GSE.
Standard

Aircraft Damage Caused by Ground Support Equipment

2009-12-09
HISTORICAL
AIR1589A
Only those incidents where a piece of ground support equipment directly associated with the "turnaround" servicing of an aircraft was involved are reviewed. Specifically excluded are those incidents that occurred during heavy maintenance, overhaul activity, or aircraft taxiing.
Standard

Aircraft Damage Caused by Ground Support Equipment

2022-05-16
CURRENT
AIR1589C
Incidents where a piece of ground support equipment or personnel damages an aircraft under the control of ground or maintenance operations that requires corrective action by aircraft maintenance personnel. Operations include, but are not limited to servicing, line maintenance, heavy maintenance, and aircraft movement, e.g., marshalling/pushback/tow/reposition/taxi.
Standard

400 Hz CONNECTION AIRCRAFT ELECTRICAL MAINTENANCE PROCEDURES

1994-12-01
HISTORICAL
AIR4365
This SAE Aerospace Information Report (AIR) describes field-level procedures to determine if 400 Hz electrical connections for external power may have been subjected to excessive wear, which may result in inadequate disengagement forces.
Standard

Method of Evaluating Pneumatic Ground Power Units

2020-09-23
CURRENT
AIR4545A
This SAE Aerospace Information Report (AIR) covers, and is restricted to, the behavior of air under conditions of critical and subcritical flow at temperatures less than 500 °F.
Standard

GROUND ELECTRICAL POWER UNIT BRUSHLESS, SYNCHRONOUS, ELECTRIC MOTOR-DRIVEN 400 HERTZ, 3-PHASE OUTPUT

1985-08-01
HISTORICAL
ARP1480
This recommended practice outlines the general requirements of a continuous duty, electric motor-driven brushless alternator unit for supplying 400 Hz electrical power to high performance commercial transport aircraft. This specification is for a single motor-generator set with one or two outputs. The generator set will generate at the aircraft voltage of 115/200 volts. This unit may be used in a central system of small size or in hangar or electronic shop applications. Power characteristics of this unit at the receptacle will meet MIL-Standard-704 requirements. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
Standard

GROUND ELECTRICAL POWER UNIT, TRANSPORTABLE 115/200 VOLT AC (NOMINAL) 400 HERTZ, 3-PHASE 4-WIRE (GROUNDED NEUTRAL) Y-CONNECTED SYSTEM

1991-05-01
HISTORICAL
ARP1148A
This Recommended Practice outlines the electrical performance characteristics for a continuous duty, diesel or gasoline engine driven brushless alternator unit for supplying 400-Hertz electrical power to commercial transport aircraft. It is intended to assist the airlines in standardizing recommendations for various sizes and configurations of equipment and it is a guide for the preparation of detailed specifications. The unit is primarily intended to supply power to the aircraft during passenger loading and unloading, and during servicing operations. The combination of the equipment specified herein and the interconnecting cables(s) between the 400-Hertz alternator and the aircraft shall provide power characteristics at the aircraft receptacle which meet MIL-STD-704 requirements for Category "B" equipment. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
Standard

GROUND ELECTRICAL POWER UNIT, TRANSPORTABLE 115/200 VOLT AC (NOMINAL) 400 HERTZ, 3-PHASE 4-WIRE (GROUNDED NEUTRAL) Y-CONNECTED SYSTEM

1970-02-01
HISTORICAL
ARP1148
This Recommended Practice outlines the general requirements for a transportable self-contained, continuous duty, diesel engine driven brushless alternator unit for supplying 400-Hertz electrical power to high performance commercial transport aircraft. It is intended to assist the airlines in standardardizing recommendations for various sizes and configurations of equipment and it is a guide for the preparation of detailed specifications by the purchaser. The unit is primarily intended to supply power to the aircraft during passenger loading and unloading, and during servicing operations at airports throughout the world. The combination of the equipment specified herein and the interconnecting cable(s) between the 400-Hertz alternator and the aircraft shall provide power characteristics at the aircraft receptacle which meet MIL-STD-704A requirements for Category "B" equipment. Other limits which are necessary to meet specific conditions must be specified by the purchaser.