Refine Your Search

Topic

Search Results

Standard

Universal Leak Detector

2017-10-25
WIP
ARP726B
This recommended practice covers a self-contained detection system which is capable of pressurizing a closed system up to 70 psig with halogen (tracer) gas and up to 3500 psig with nitrogen. An external tracer gas supply may be used to increase the capacity of the system. The detector shall be capable of detecting leaks as small as .05 ounce of tracer gas per year, with a system pressure of 70 psig or less. The purpose of this document is to provide a recommended practice for the design of a universal leak detector which will pressurize a closed system with a mixture of inert and tracer gas and provide a probe and detector to indicate location and rate of system leakage with a high degree of accuracy.
Standard

UNIVERSAL TURNOVER BUILD-UP STAND FOR SMALL PROPULSION UNITS REQUIRING VERTICAL ASSEMBLY

1968-05-15
HISTORICAL
ARP863
This recommended practice covers a stand that may be used for assembly, disassembly, and maintenance. The stand incorporates the following design criteria: complete interchangeability of any and all components, collapsible frame construction, envelope dimensions (marked with an asterik on the attached drawings), attachment pad configuration, and gearbox and caster specifications.
Standard

Universal Turnover Build-Up Stand for Small Propulsion Units Requiring Vertical Assembly

1997-12-01
HISTORICAL
ARP863A
This recommended practice covers a stand that may be used for assembly, disassembly, and maintenance. The stand incorporates the following design criteria: complete interchangeability of any and all components, collapsible frame construction, envelope dimensions (marked with an asterisk on the attached drawings), attachment pad configuration, and gearbox and caster specifications.
Standard

Universal Turnover Build-Up Stand for Small Propulsion Units Requiring Vertical Assembly

2012-12-05
CURRENT
ARP863B
This recommended practice covers a stand that may be used for assembly, disassembly, and maintenance. The stand incorporates the following design criteria: complete interchangeability of any and all components, collapsible frame construction, envelope dimensions (marked with an asterisk on the attached drawings), attachment pad configuration, and gearbox and caster specifications.
Standard

Cover, Shipping and Storage (Flexible, Reusable, Water-Vaporproof)

2017-10-25
WIP
ARP4166A
This Aerospace Recommended Practice (ARP) defines and establishes design, construction, and performance requirements for a flexible, reusable, water-vaporproof cover for environmental protection of internal combustion engines, major components, and other military and commercial items.
Standard

Stands, Shipping and Storage, Aircraft Engines, Reusable

2017-10-25
WIP
ARP4898A
This SAE Aerospace Recommended Practice (ARP) recommends design and test criteria for reusable shipping and storage stands for aircraft engines. An optional hard cover (enclosure) is also specified.
Standard

UNIVERSAL HORIZONTAL FIELD MAINTENANCE STAND FOR 10,000 LB. WEIGHT CLASS PROPULSION UNITS (48" AND 30" RAIL GAGE)

1960-03-01
HISTORICAL
ARP581
This recommended practice covers a rail concept stand that may be used for horizontal disassembly and reassembly, and maintenance, incorporating certain design features which are defined herein. These features include the rail dimensions and width, length and height of stand to insure compatibility with rail concept type transport and positioning trailers.
Standard

Universal Horizontal Field Maintenance Stand for 10,000 pound Weight Class Propulsion Units (48 inch and 30 inch Rail Gage)

2012-12-05
CURRENT
ARP581B
This recommended practice covers a rail concept stand that may be used for horizontal disassembly and reassembly, and maintenance, incorporating certain design features which are defined herein. These features include the rail dimensions and width, length and height of stand to insure compatibility with rail concept type transport and positioning trailers.
Standard

Universal Horizontal Field Maintenance Stand for 10,000 pound Weight Class Propulsion Units (48 inch and 30 inch Rail Gage)

1997-12-01
HISTORICAL
ARP581A
This recommended practice covers a rail concept stand that may be used for horizontal disassembly and reassembly, and maintenance, incorporating certain design features which are defined herein. These features include the rail dimensions and width, length and height of stand to insure compatibility with rail concept type transport and positioning trailers.
Standard

UNIVERSAL TURNOVER BUILD-UP STAND SERIES FOR PROPULSION UNITS AND/OR COMPONENTS

1962-01-01
HISTORICAL
ARP680A
This recommended practice covers a series of stands that may be used for assembly, disassembly and maintenance; incorporating the following design criteria: a collapsible frame construction, envelope dimensions, attachment shear pad configuration and gear box and caster specifications.
Standard

UNIVERSAL TURNOVER BUILD-UP STAND SERIES FOR PROPULSION UNITS AND/OR COMPONENTS

1968-10-01
HISTORICAL
ARP680B
This recommended practice covers a series of stands that may be used for assembly, disassembly and maintenance; incorporating the following design criteria: a collapsible frame construction, envelope dimensions, attachment shear pad configuration and gear box and caster specifications.
Standard

Drum, Metal-Shipping and Storage

2001-03-01
CURRENT
AS6054
This specification covers new cylindrical drums to be used as exterior shipping containers (see 6.1).
X