Refine Your Search

Topic

Search Results

Standard

Electric Drive Cooling Fan Motor Mounting

2010-07-08
HISTORICAL
J2873_201007
This SAE Recommended Practice is applicable to Electric Drive Cooling Fan Assemblies used in Light Duty vehicle cooling systems (typically, passenger cars and light duty trucks). This document outlines the Electric Drive Cooling Fan Motor Mounting interface characteristics such that a common standard is possible.
Standard

Electric Drive Cooling Fan Motor Mounting

2016-03-11
CURRENT
J2873_201603
This SAE Recommended Practice is applicable to Electric Drive Cooling Fan Assemblies used in Light Duty vehicle cooling systems (typically, passenger cars and light duty trucks). This document outlines the Electric Drive Cooling Fan Motor Mounting interface characteristics such that a common standard is possible.
Standard

Laboratory Testing of Light Duty Vehicle Electric Cooling Fan Assemblies for Airflow Performance

2014-08-28
HISTORICAL
J2867_201408
This SAE Recommended Practice is intended for use in testing and evaluating the performance of Light Duty automotive electric engine cooling fans. These Electric Cooling Fan (ECF) Assemblies are purchased by Light Duty Truck and Passenger Car OEM’s from suppliers. They are purchased as complete assemblies, consisting of the fan(s), motor(s), and shroud (see Figure 1); this Recommended Practice will only consider such complete assemblies. Some purchased assemblies using brush-type motors may also include control devices such as power resistors or pulse width modulation (PWM) electronics for speed control. In the case of brushless motor technology, the controller is an integral part of the motor where it also performs the commutation process electronically. The performance measurement would include fan output in terms of airflow and pressure, and fan input electric power in terms of voltage and current.
Standard

Exhaust Gas Recirculation (EGR) Cooler Nomenclature and Application

2022-11-22
CURRENT
J2914_202211
This document provides an overview on how and why EGR coolers are utilized, defines commonly used nomenclature, discusses design issues and trade-offs, and identifies common failure modes. The reintroduction of selectively cooled exhaust gas into the combustion chamber is just one component of the emission control strategy for internal combustion (IC) engines, both diesel and gasoline, and is useful in reducing exhaust port emission of nitrogen oxides (NOx). Other means of reducing NOx exhaust port emissions are briefly mentioned, but beyond the scope of this document.
Standard

Exhaust Gas Recirculation (EGR) Cooler Nomenclature and Application

2016-08-23
HISTORICAL
J2914_201608
This document provides an overview on how and why EGR coolers are utilized, defines commonly used nomenclature, discusses design issues and trade-offs, and identifies common failure modes. The reintroduction of exhaust gas into the combustion chamber is just one component of the emission control strategy for internal combustion (IC) engines, both diesel and gasoline, and is useful in reducing exhaust port emission of Nitrogen Oxides (NOx). Other means of reducing NOx exhaust port emissions are briefly mentioned, but beyond the scope of this document.
Standard

ENGINE COOLANT CONCENTRATE—ETHYLENE-GLYCOL TYPE

1973-06-01
HISTORICAL
J1034_197306
This standard covers glycol-type compounds which, when added to engine cooling systems at concentrations of 40-70% by volume of coolant concentrate in water, provide corrosion protection, lower the freezing point, and raise the boiling point of the coolant. Such compounds are intended for a minimum of 1 year (approximately 12,000 miles) service in a properly maintained cooling system. (Reference: SAE HS-40, Maintenance of Automotive Engine Cooling Systems.) Coolants meeting this standard do not require the use of supplementary materials. For additional information on engine coolants, see SAE J814.
Standard

ENGINE COOLANT CONCENTRATE - ETHYLENE-GLYCOL TYPE

1988-07-01
HISTORICAL
J1034_198807
This standard covers glycol-type compounds which, when added to engine cooling systems at concentrations of 50 - 70% by volume of coolant concentrate in water, provide corrosion protection, lower the freezing point, and raise the boiling point of the coolant. Such compounds are intended for a minimum of 1 year (approximately 12 000 miles) service in a properly maintained cooling system. (Reference: SAE HS-40, Maintenance of Automotive Engine Cooling. Systems.) Coolants meeting this standard do not require the use of supplementary materials. For additional information on engine coolants, see SAE J814. Heavy-duty non-automotive and heavy-duty diesel engine coolant maintenance may require different measurement and test parameters due to differences in engine design and materials, and high mileage service requirements.
Standard

COOLANT CONCENTRATE (LOW SILICATE, ETHYLENE GLYCOL TYPE REQUIRING AN INITIAL CHARGE OF SUPPLEMENTAL COOLANT ADDITIVE) FOR HEAVY-DUTY ENGINES

1990-04-01
HISTORICAL
J1941_199004
This SAE Recommended Practice applies to engine coolant concentrate, low silicate ethylene glycol base, for use in cooling systems of heavy-duty engines. An initial charge of supplemental coolant additive (SCA) is required when using this type of coolant concentrate. This document applies to engine coolant concentrates for heavy-duty engine requirements. SAE J1034 applies to coolant concentrates for automobile and light truck applications. For further information on engine coolants, see SAE J814.
Standard

TEST METHOD FOR MEASURING POWER CONSUMPTION OF FAN DRIVE SYSTEMS FOR TRUCKS AND BUSES

1981-07-01
HISTORICAL
J1342_198107
The testing technique outlined in this SAE Recommended Practice was developed as part of an overall program for testing and evaluating fuel consumption of heavy-duty trucks and buses. The technique outlined in this recommended practice provides a general description of the type of equipment and facility which is necessary to determine the power consumption of these engine-driven components. It is recommended that the specific operating conditions suggested be carefully reviewed on the basis of actual data obtained on the specific vehicle operation. Because of the variation in size, shape, configuration, and mountings available in cooling fans and fan drive systems, specific test devices have not been included.
Standard

METHOD FOR DETERMINING POWER CONSUMPTION OF ENGINE COOLING FAN-DRIVE SYSTEMS

1994-09-01
HISTORICAL
J1342_199409
The technique outlined in this SAE Recommended Practice was developed as part of an overall program for determining and evaluating fuel consumption of heavy-duty trucks and buses. It is recommended that the specific operating conditions be carefully reviewed on the basis of actual installation data. Cooling requirements are affected by all heat exchangers that are cooled by the fan-drive system. These may include radiators, condensers, charge air coolers, or oil coolers. Because of the variation in size, shape, configuration, and mountings available in cooling fans and fan-drive systems, specific test devices have not been included. Using known power/speed relationships for a given fan, this procedure can be used to calculate the fan-drive system’s power consumption for engine cooling systems using fixed-ratio, speed modulating, and on-off fan drives. This power consumption may then be used in determining engine net power per SAE J1349.