Refine Your Search

Topic

Author

Affiliation

Search Results

Technical Paper

Comparison of PMHS, WorldSID, and THOR-NT Responses in Simulated Far Side Impact

2007-10-29
2012-01-1537
Injury to the far side occupant has been demonstrated as a significant portion of the total trauma in side impacts. The objective of the study was to determine the response of PMHS in far side impact configurations, with and without generic countermeasures, and compare responses to the WorldSID and THOR dummies. A far side impact buck was designed for a sled test system that included a center console and three-point belt system. The buck allowed for additional options of generic countermeasures including shoulder or thorax plates or an inboard shoulder belt. The entire buck could be mounted on the sled in either a 90-degree (3-o'clock PDOF) or a 60-degree (2-o'clock PDOF) orientation. A total of 18 tests on six PMHS were done to characterize the far side impact environment at both low (11 km/h) and high (30 km/h) velocities. WorldSID and THOR-NT tests were completed in the same configurations to conduct matched-pair comparisons.
Technical Paper

Thoracic Deformation Contours in a Frontal Impact

1991-10-01
912891
The objective of the study was to document the thoracic deformation contours in a simulated frontal impact. Unembalmed human cadavers and the Hybrid III anthropomorphic manikins were tested. Data from the newly developed External Peripheral Instrument for Deformation Measurement (EPIDM) was used to derive deformation patterns at upper and lower thoracic levels. Deceleration sled tests were conducted on three-point belt restrained surrogates positioned in the driver's seat (no steering assembly) using a horizontal impact test sled at velocities of approximately 14.0 m/s. Lap and shoulder belt forces were recorded with seat belt transducers. The experimental protocol included a Hybrid III manikin experiment followed by the human cadaver test. Both surrogates were studied under similar input and instrumentation conditions, and identical data acquisition and analysis procedures were used. All six testedcadavers demonstrated multiple bilateral rib fractures.
Technical Paper

Response and Tolerance of the Human Forearm to Impact Loading

1998-11-02
983149
With the widespread use of supplemental restraint systems (airbags), occasional rare injuries have occurred because of the force associated with these systems upon deployment. Recent case studies have demonstrated forearm fractures associated with airbag deployment. The present study was conducted to determine the tolerance of the human forearm under a dynamic bending mode. A total of 30 human cadaver forearm specimens were tested using three-point bending protocol to failure at 3.3 m/s and 7.6 m/s velocities. Results indicated significantly (p < 0.01) greater biomechanical parameters associated with males compared to females. The bending tolerance of the human forearm, however, was found to be most highly correlated to bone mineral density, bone area, and forearm mass. Thus, any occupant with lower bone mineral density and lower forearm geometry/mass is at higher risk. The mean failure bending moment for all specimens was 94 Nm.
Technical Paper

Responses of Human Surrogates to Simulated Rear Impact: Velocity and Level Dependent Facet Joint Kinematics

2001-03-05
2001-01-0175
The objective of the present study was to determine the kinematics of the human head-neck complex with specific reference to posterior facet joints as a function of rear impact acceleration. Six intact human head-neck complexes were prepared by fixing the first thoracic vertebra in polymethylmethacrylate. The specimens were oriented such that the Frankfurt plane was horizontal and the cervico-thoracic disc was at an angle of 25 degrees to simulate the normal driving position. Retroreflective targets were inserted to the cervical vertebrae. The specimens were subjected to simulated rear impact accelerations using a minisled apparatus. A series of tests were conducted with velocities of 2.1, 4.6, 6.6, 9.3, and 12.4 km/h. In this study, to achieve the objective, results are presented on the facet joint motions at the C4–5, C5–6, and C6–7 levels as a function of change in velocity.
Technical Paper

Improved thorax behavior of the EUROSID and effects on thorax injury assessment, on the basis of pendulum impacts

2001-06-04
2001-06-0141
In 1989, the EUROSID-1 was accepted in the European regulation ECE-R95. After a steady period of use, an upgraded version of this dummy: ES-2 is now considered as a step towards harmonization of side impact occupant regulations. The upgrades to the dummy include, amongst others, a modification of its torso back plate and a change in rib module guidance (piston-cylinder), especially to overcome anomalous rib deflection responses referred to as ""flat-top.'' Presented here are results of lateral and oblique pendulum tests, conducted on the EUROSID-1 and ES-2 to verify the modified torso back plate and to study the responses of three proposed rib module designs for ES-2. Particularly, rib deflections, rib VC responses, and thorax force-deflection responses are analyzed. The current study primarily addresses sensitivity of the ES-2 thorax to oblique loading.
Technical Paper

Biomechanics of Inertial Head-Neck Trauma: Role of Cervical Components

2002-03-19
2002-01-1445
Inertial loading of the head-neck complex occurs in rear impacts wherein the head and neck of the occupant are initially subjected to rearward forces. Epidemiological evidence exists to demonstrate the significance and societal impact of these injuries [4]. From a clinical perspective, trauma secondary to inertial loads belongs to the lower end of the Abbreviated Injury Scale, and no specific diagnostic techniques are available to quantitatively document the injury. Furthermore, identification of the mechanisms of injury and derivation of injury thresholds are limited. In fact, there is a paucity of literature focusing on the reproduction of rear impact-induced neck injuries due to a single-event rear impact. Because the impact acceleration is transmitted to the head from the torso via the cervical column, the components of the human neck play a role in the mechanics of trauma.
Technical Paper

Biodynamics of the Total Human Cadaveric Cervical Spine

1990-10-01
902309
Spinal trauma produced from motor vehicle accidents, diving accidents, or falls occur at high rates of loading. This study was undertaken to reproduce clinically relevant cervical spine injuries under controlled conditions. Six isolated head - T2 human cadaveric preparations were tested using an electrohydraulic piston actuator at loading rates from 295 to 813 cm/sec. The Hybrid III head-neck was tested similarly at rates from 401 to 683 cm/sec. The input forces for specimen tests were of higher magnitude and shorter duration than the distally measured forces. In contrast, the Hybrid III head-neck revealed similar magnitude and duration force traces from input to output. The specimen preparations were analyzed kinematically at 1200 frames/sec with 20 to 30 retroreflective targets fixed to each level of the cervical spine. With this technique it is possible to temporally follow cervical damage as a function of applied force.
Technical Paper

Thoracic Biomechanics with Air Bag Restraint

1993-11-01
933121
The objective of the present study was to determine the biomechanics of the human thorax in a simulated frontal impact. Fourteen unembalmed human cadavers were subjected to deceleration sled tests at velocities of nine or 13 m/s. Air bag - knee bolster, air bag - lap belt, and air bag - three-point belt restraint systems were used with the specimen positioned in the driver's seat. Two chest bands were used to derive the deformation patterns at the upper and lower thoracic levels. Lap and shoulder belt forces were recorded with seatbelt transducers. After the test, specimens were evaluated using palpation, radiography, and a detailed autopsy. Thoracic trauma was graded according to the Abbreviated Injury Scale based on autopsy findings. Peak thoracic deformations were normalized with respect to the initial chest depth to facilitate comparison between the specimens.
Technical Paper

Biomechanical Tolerance of the Cranium

1994-09-01
941727
The objective of the study was to investigate the biomechanical response of the intact cranium. Unembalmed human cadavers were used in the study. The specimens were transected at the base of the skull leaving the intracranial contents intact; x-ray and computed tomography (CT) scans were obtained. They were fixed in a specially designed frame at the auditory meatus level and placed on the platform of an electrohydraulic testing device via a six-axis load cell. Following radiography, quasistatic loading to failure was applied to one of the following sites: frontal, vertex, parietal, temporal, or occipital. Retroreflective targets were placed in two mutually orthogonal planes to record the localized temporal kinematics. Applied load and piston displacement, and the output generalized force (and moment) histories were recorded using a modular digital data acquisition system. After the test, x-ray and CT images were obtained, and defleshing was done.
Technical Paper

Biomechanical Analysis of Tractor Induced Head Injury

1994-09-01
941726
Head injury is a serious threat to lives of people working around farm machinery. The consequence of head injuries are costly, paralytic, and often fatal. Clinical and biomechanical data on head injuries are reviewed and their application in the analysis of head injury risk associated with farm tractor discussed. A significant proportion of tractor-related injuries and deaths to adults, as well as children, is due directly or indirectly to head injury. An improved injury reporting program and biomechanical studies of human response to tractor rollover, runover, and falls, are needed to understand mechanisms of the associated head injury.
Technical Paper

Dynamic Axial Tolerance of the Human Foot-Ankle Complex

1996-11-01
962426
Axial loading of the calcaneus-talus-tibia complex is an important injury mechanism for moderate and severe vehicular foot-ankle trauma. To develop a more definitive and quantitative relationship between biomechanical parameters such as specimen age, axial force, and injury, dynamic axial impact tests to isolated lower legs were conducted at the Medical College of Wisconsin (MCW). Twenty-six intact adult lower legs excised from unembalmed human cadavers were tested under dynamic loading using a mini-sled pendulum device. The specimens were prepared, pretest radiographs were taken, and input impact and output forces together with the pathology were obtained using load cell data. Input impact forces always exceeded the forces recorded at the distal end of the preparation. The fracture forces ranged from 4.3 to 11.4 kN.
Technical Paper

Kinematic and Anatomical Analysis of the Human Cervical Spinal Column Under Axial Loading

1989-10-01
892436
The patho-anatomic alterations due to vertical loading of the human cervical column were documented and correlated with biomechanical kinematic data. Seven fresh human cadaveric head-neck complexes were prepared, and six-axis load cells were placed at the proximal and distal ends of the specimens to document the gross biomechanical response. Retroreflective markers were placed on bony landmarks of vertebral bodies, articular facets, and spinous processes along the entire cervical column. Targets were also placed on the occiput and arch of C1. The localized movements of these markers were recorded using a video analyzer during the entire loading cycle. Pre-test two-dimensional, and three-dimensional computerized tomography (CT), and plane radiographs were taken. The specimens were loaded to failure using an electrohydraulic testing device at a rate of 2 mm/s.
Technical Paper

Steering Wheel Induced Facial Trauma

1988-10-01
881712
Studies were conducted on twenty-two fresh human cadavers to determine the probability of facial bone fracture following dynamic contact with steering wheel assemblies of both standard (a commercially available) and energy absorbing (EA) types. Using a specially designed and validated vertical-drop impact test system, either zygoma was impacted once onto the junction of the lower left spoke and rim with velocities ranging from 2.0 to 6.9 m/s. Generalized force histories were recorded with a six-axis load cell placed below the hub. The wheel was inclined 30 degrees to the horizontal. Steering wheel deformations were recorded with a system of potentiometers placed below the impact site on the wheel. Dynamic forces at the zygoma (impact site) were computed using transformation principles. A triaxial accelerometer was placed at the posterior parietal region of the specimen opposite to the impact site to record acceleration histories. High speed photography documented the kinematics.
Technical Paper

Tractor Induced Wheel Runover Injuries

1994-09-01
941728
In the present investigation a tractor wheel runover accident was simulated to obtain biomechanical information relating to mechanism of injury. Twelve cadaver porcine specimens were runover with the right front wheel of a tractor. Specimens were placed on a six-axis force plate and thorax contours were recorded temporally. Results indicated up to 68% compression of the chest occurred during the runover event. The shear force in the direction of travel was a significant factor in the type of fractures that occurred to the rib cage. Pathology determined from x-ray revealed multiple fractures per rib in the area directly below the path of the tire. Autopsy evaluation revealed soft tissue contusion on the left side in the area of wheel path. There was often extra blood in the pericardial space and examination of the brain showed petechial hemorrhaging subdurally.
Technical Paper

Epidemiology and Injury Biomechanics of Motor Vehicle Related Trauma to the Human Spine

1989-10-01
892438
Engineering efforts directed at better occupant safety require a thorough understanding of available epidemiologic data. Epidemiologic studies using clinical as well as accident information facilitates the prioritization of biomechanics research so that controlled laboratory experimentation and/or analytical models can be advanced. This information has also value in dictating levels and types of injury that are critical to the development of anthropomorphic test devices used in crash environments. In this paper, motor vehicle accident related (excluding pedestrians, bicyclists, and motorcyclists) epidemiologic data were obtained from clinical and computerized accident (National Accident Sampling System-NASS) files. Clinical data were gathered from patients admitted to the Medical College of Wisconsin Affiliated Hospitals, and fatalities occurring in Milwaukee County, State of Wisconsin. NASS database with specific focus on spinal injuries of motor vehicle occupants was also used.
Technical Paper

Age-Specific Pediatric Cervical Spine Biomechanical Responses: Three-Dimensional Nonlinear Finite Element Models

1997-11-12
973319
In this study, three-dimensional nonlinear finite element models of age-specific one year old, three year old, and six year old pediatric human cervical spine (C4-C5-C6) structures were developed. Their biomechanical responses were compared with the adult human cervical spine behavior under different loadings and at all load levels. The adult human cervical spine model was constructed from close-up computed tomography sections in the axial and sagittal planes, and sequential anatomic cryomicrotome sections. The adult model was validated with experimental moment-rotation data under flexion-extension and compression by correlating bilateral strains in the vertebral body and the lateral masses, and the force-deflection responses with experiments conducted in our laboratory. The adult model was modified to create one, three and six year old pediatric spines by incorporating the local geometrical and material characteristics of the developmental anatomy.
Technical Paper

Biomechanics of Human Occupants in Simulated Rear Crashes: Documentation of Neck Injuries and Comparison of Injury Criteria

2000-11-01
2000-01-SC14
The objective of this study was to subject small female and large male cadavers to simulated rear impact, document soft-tissue injuries to the neck, determine the kinematics, forces and moments at the occipital condyles, and evaluate neck injury risks using peak force, peak tension and normalized tension-extension criteria. Five unembalmed intact human cadavers (four small females and one large male) were prepared using accelerometers and targets at the head, T1, iliac crest, and sacrum. The specimens were placed on a custom- designed seat without head restraint and subjected to rear impact using sled equipment. High-speed cameras were used for kinematic coverage. After the test, x-rays were obtained, computed tomography scans were taken, and anatomical sections were obtained using a cryomicrotome. Two female specimens were tested at 4.3 m/s (mean) and the other two were tested at 6.8 m/s (mean), and one large male specimen was subjected to 6.6 m/s velocity.
Technical Paper

Mechanisms and Factors Involved in Hip Injuries During Frontal Crashes

2001-11-01
2001-22-0020
This study was conducted to collect data and gain insights relative to the mechanisms and factors involved in hip injuries during frontal crashes and to study the tolerance of hip injuries from this type of loading. Unembalmed human cadavers were seated on a standard automotive seat (reinforced) and subjected to knee impact test to each lower extremity. Varying combinations of flexion and adduction/abduction were used for initial alignment conditions and pre-positioning. Accelerometers were fixed to the iliac wings and twelfth thoracic vertebral spinous process. A 23.4-kg padded pendulum impacted the knee at velocities ranging from 4.3 to 7.6 m/s. The impacting direction was along the anteroposterior axis, i.e., the global X-axis, in the body-fixed coordinate system. A load cell on the front of the pendulum recorded the impact force. Peak impact forces ranged from 2,450 to 10,950 N. The rate of loading ranged from 123 to 7,664 N/msec. The impulse values ranged from 12.4 to 31.9 Nsec.
Technical Paper

Analysis of Force Mitigation by Boots in Axial Impacts using a Lower Leg Finite Element Model

2020-03-31
2019-22-0011
Lower extremity injuries caused by floor plate impacts through the axis of the lower leg are a major source of injury and disability for civilian and military vehicle occupants. A collection of PMHS pendulum impacts was revisited to obtain data for paired booted/unbooted test on the same leg. Five sets of paired pendulum impacts (10 experiments in total) were found using four lower legs from two PMHS. The PMHS size and age was representative of an average young adult male. In these tests, a PMHS leg was impacted by a 3.4 or 5.8 kg pendulum with an initial velocity of 5, 7, or 10 m/s (42-288 J). A matching LS-DYNA finite element model was developed to replicate the experiments and provide additional energy, strain, and stress data. Simulation results matched the PMHS data using peak values and CORA curve correlations. Experimental forces ranged between 1.9 and 12.1 kN experimentally and 2.0 and 11.7 kN in simulation.
Technical Paper

Oblique Lateral Impact Biofidelity Deflection Corridors from Post Mortem Human Surrogates

2013-11-11
2013-22-0016
The objective of the study was to determine the thorax and abdomen deflection-time corridors in oblique side impacts. Data were analyzed from Post Mortem Human Surrogate (PMHS) sled tests, certain aspects of which were previously published. A modular and scalable anthropometry-specific segmented load-wall system was fixed to the platform of the sled. Region-specific forces were recorded from load cells attached to the load-wall plates. The thorax and abdomen regions were instrumented with chestbands, and deflection contours were obtained. Biomechanical responses were processed using the impulse-momentum normalization method and scaled to the mid-size male mass, 76-kg. The individual effective masses of the thorax and abdomen were used to determine the scale factors in each sled test, thus using the response from each experiment. The maximum deflections and their times of attainments were obtained, and mean and plus minus one standard deviation corridors were derived.
X