Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design - Truck and Bus

2008-01-14
HISTORICAL
J2698_200801
1.1 This SAE Recommended Practice covers the design and application of primary on-board wiring distribution system harnessing for surface vehicles. This document is intended for single phase nominal 120 VAC circuits that provide power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off. The power supply comes from alternative sources such as land-based grid power, DC-AC inverters and auxiliary power generators. The circuits may also provide power to improve vehicle performance through charging batteries or operating cold-weather starting aids. 1.2 This document is not intended to provide guidance for electric or hybrid electric vehicle wiring circuits. Refer to SAE J1673 for high voltage automotive wiring assembly design. 1.3 Engine block heaters are 120 VAC devices that are used on a multitude of vehicle platforms in addition to trucks with sleeper cabs. Generally, the engine block heater circuit is wired independent of hotel loads.
Standard

Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design—Truck and Bus

2018-10-04
CURRENT
J2698_201810
This SAE Recommended Practice covers the design and application of primary on-board wiring distribution system harnessing for surface vehicles. This document is intended for single phase nominal 120 VAC circuits that provide power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off. The power supply comes from alternative sources such as land-based grid power, DC-AC inverters and auxiliary power generators. The circuits may also provide power to improve vehicle performance through charging batteries or operating cold-weather starting aids.
Standard

Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design—Truck and Bus

2014-11-24
HISTORICAL
J2698_201411
This SAE Recommended Practice covers the design and application of primary on-board wiring distribution system harnessing for surface vehicles. This document is intended for single phase nominal 120 VAC circuits that provide power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off. The power supply comes from alternative sources such as land-based grid power, DC-AC inverters and auxiliary power generators. The circuits may also provide power to improve vehicle performance through charging batteries or operating cold-weather starting aids.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2013-04-09
HISTORICAL
J2691_201304
This SAE standard establishes the minimum construction and performance requirements for a 15 Pole Connector Between Towing Vehicles and Trailers, for trucks, trailers, and dollies in conjunction with SAE J2742 “Combination 11 Conductors and 4 Pairs ECBS Cable”. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2018-04-15
CURRENT
J2691_201804
This SAE standard establishes the minimum construction and performance requirements for a 15 Pole Connector Between Towing Vehicles and Trailers, for trucks, trailers, and dollies in conjunction with SAE J2742. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

Positive Temperature Coefficient Overcurrent Protection Devices (PTCs)

2014-12-03
CURRENT
J2685_201412
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for PTC (positive temperature coefficient of resistance) overcurrent protection devices. PTCs are typically either polymeric (PPTC) or ceramic (CPTC). It is important to note battery voltages versus powernets/system voltage versus max battery voltages: (12 V/14 V/16 V, 24 V/28 V/32 V, and 36 V/42 V/58 V). All voltages are DC. These devices are typically rated with a maximum operating voltage, which for vehicular systems need to be 16 V (for 12 V batteries), 32 V (for 24 V batteries), and 58 V (for 36 V batteries/42 V powernets). PTC devices are considered to be self-resetting after responding to overcurrent conditions and after such condition has been removed from the affected circuit containing the PTC.
Standard

Auxiliary Two Conductor Electrical Power Connector for Truck-Trailer High Power Jumper Cable

2018-10-04
WIP
J3082
This SAE Standard provides the minimum requirements for high power two conductor jumper cable plug and receptacle for truck-trailer jumper cable systems. It includes the test procedures, design, and performance requirements. This document covers receptacles rated at more than 30A (Ampere) up to and including 150A and is intended for a single circuit with one power conductor and one common return conductor. Single conductor high current connectors are not recommended for future designs because of inadequate ground return through 5th wheel / king pin. Cable size selection is to be made by the vehicle OEM for specific applications and the specific voltage drop requirements of those applications. This SAE Standard covers two variants of high power two conductor connections: a heavy duty version with horizontally aligned pins, typically for lift-gate battery charging and a medium duty version with vertically aligned pins: typically for loads such as power tarpaulins.
Standard

Auxiliary Two Conductor Electrical Power Connector for Truck-Trailer High Power Jumper Cable

2015-11-24
CURRENT
J3082_201511
This SAE Standard provides the minimum requirements for high power two conductor jumper cable plug and receptacle for truck-trailer jumper cable systems. It includes the test procedures, design, and performance requirements. This document covers receptacles rated at more than 30A (Ampere) up to and including 150A and is intended for a single circuit with one power conductor and one common return conductor. Single conductor high current connectors are not recommended for future designs because of inadequate ground return through 5th wheel / king pin. Cable size selection is to be made by the vehicle OEM for specific applications and the specific voltage drop requirements of those applications. This SAE Standard covers two variants of high power two conductor connections: a heavy duty version with horizontally aligned pins, typically for lift-gate battery charging and a medium duty version with vertically aligned pins: typically for loads such as power tarpaulins.
Standard

Combination 11 Conductors and 2 Pairs ECBS Cable

2018-06-03
CURRENT
J2742_201806
This SAE standard establishes the minimum construction and performance requirements for a combination cable consisting of 11 conductors and 2 twisted pairs for use on trucks, trailers, and dollies in conjunction with SAE J2691. (15 pole connectors.) The cable includes both power and unjacketed SAE J1939-15 paired signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

Combination 11 Conductors and 4 Pairs ECBS Cable

2013-04-09
HISTORICAL
J2742_201304
This SAE standard establishes the minimum construction and performance requirements for a combination cable consisting of 11 conductors and 4 twisted pairs for use on trucks, trailers, and dollies in conjunction with SAEJ2691. (15 pole connectors.) The cable includes both power and unjacketed SAE J1939-15 paired signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

Circuit Breaker--Internal Mounted--Automatic Reset

1971-06-01
HISTORICAL
J258_197106
An internally mounted circuit breaker is one mounted within an automotive switch or other automotive device for protection against overload of the wiring. In a given application,, this same circuit breaker may be designed to protect against overload of the electrically operable devices.
Standard

Heavy Duty High Speed Datalink Connector

2010-02-18
HISTORICAL
J2839_201002
This SAE Recommended Practice defines the performance requirements, size and mating interfaces for M12 style 4 and 5 pole Heavy Duty High Speed Datalink connection systems, and applies to both cable-to-cable and cable-to-device connectors.
Standard

Heavy Duty High Speed Datalink Connector

2015-07-08
CURRENT
J2839_201507
This SAE Recommended Practice defines the performance requirements, size and mating interfaces for M12 style 4 and 5 pole Heavy Duty High Speed Datalink connection systems, and applies to both cable-to-cable and cable-to-device connectors.
Standard

Auxiliary Power Unit Electrical Interface Requirements for Class Eight Trucks

2010-07-06
HISTORICAL
J2891_201007
This SAE Recommended Practice covers the design and application of a 120 VAC single phase engine based auxiliary power unit or GENSET. This document is intended to provide design direction for the single phase nominal 120 VAC as it interfaces within the truck architecture providing power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off.
Standard

Auxiliary Power Unit Electrical Interface Requirements for Class Eight Trucks

2015-12-18
CURRENT
J2891_201512
This SAE Recommended Practice covers the design and application of a 120 VAC single phase engine based auxiliary power unit or GENSET. This document is intended to provide design direction for the single phase nominal 120 VAC as it interfaces within the truck architecture providing power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off.
Standard

Positive Temperature Coefficient Overcurrent Protection Devices (PTCs)

2006-05-18
HISTORICAL
J2685_200605
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for P.T.C. overcurrent protection devices in amperage rating 30A or less. These devices are also typically rated with a maximum operating voltage, which for vehicular systems need to be 16 V (for 12 V systems)(, 32 V (for 24 V systems), and 58 V (for 42 V systems). P.T.C. devices are considered to be self-resetting after responding to overcurrent conditions and after such condition has been removed from the affected circuit containing the P.T.C.
Standard

Seven-Conductor Cable

1973-10-01
HISTORICAL
J1067_197310
This SAE Standard establishes the minimum construction and performance requirements for seven-conductor 1/8-1/10-5/12 cable for use on trucks and trailers. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications.
Standard

Seven Conductor Cable - Truck and Bus

2007-06-12
HISTORICAL
J1067_200706
This SAE standard establishes the minimum construction and performance requirements for seven-conductor 1/8-1/10-5/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications.