Refine Your Search

Topic

null

Search Results

Standard

Ergonomic Guidelines for Carts and Dollies

2015-03-13
USCAR41
This document describes the assessment methods and physical requirements associated with the manual handling of carts and dollies, specific to material handling systems. All possible designs and applications could not be anticipated in creating these guidelines. Where there are questions of adherence to this document, such as use of an “off-the shelf” design, always consult the responsible Ergonomics Department. Force guidelines were primarily developed referencing the push/pull psychophysical Snook data contained in A Guide to Manual Materials Handling (second edition) by Mital, Nicholson and Ayoub (NY: Taylor & Francis, 1997). The force guidelines accommodate 75% of female capabilities and 99% of male capabilities. Factors that were included in the established guideline include: push / pull distances, vertical hand height, horizontal hand height, frequency and wheel / castor alignment and load rating. These factors were used to develop a conservative force guideline.
Standard

STANDARD FOR D.C. BRUSH MOTOR - HVAC BLOWERS

2020-11-19
USCAR6-1
This standard sets forth the performance and durability requirements for 12-volt, D.C. brush-type electric motors used for automobile Heating, Ventilation, and Air Conditioning (HVAC) blowers and outlines Production Validation and Continuing Conformance testing.
Standard

STANDARD FOR D.C. BRUSH MOTOR – HVAC BLOWERS

1999-02-01
USCAR6
This standard sets forth the performance and durability requirements for 12-volt, D.C. brush-type electric motors used for automobile Heating, Ventilation, and Air Conditioning (HVAC) blowers and outlines Production Validation and Continuing Conformance testing.
Standard

ERGONOMICS SPECIFICATION FOR MANUALLY SEATED FASTENERS

2020-12-30
USCAR47
This document describes the assembly force guidelines for manually seated push-pins, clips, and similar retention devices. For the purpose of this document, the term “clip” is used to reference all retention devices addressed within this document. Applicable retention devices must have force exerted directly to the clip using the finger/thumb and are hand seated independent of other fasteners. For a retention device to be manually installed and seated independent of other retention devices, it must be seated fully without any interaction with an adjacent fastener (i.e., multiple PIA clips on the back of a hard trim panel). This standard applies to contact surfaces angled at 90 degrees (±10 degrees) and/or perpendicular from the direction of force insertion. Mechanically installed fasteners (screws, rivets, etc.) are not included in this document. This standard does not apply to extraction/retention forces.
Standard

SPECIFICATION FOR TESTING GAS DISCHARGE LIGHT SOURCE SUBSYSTEM

2022-03-02
USCAR27-1
This specification is a general level subsystem light source specification that establishes test requirements of a Gas Discharge Light Source (GDLS) subsystem for use on passenger vehicles. The completed test data to this test specification is intended to be provided to the OEM by the Tier one lamp set maker as part of the lamp assembly PPAP. Re-testing shall be required if any portion of the approved GDLS experiences a design, manufacturing or component change. This document shall be applied to systems that meet the requirements for design, performance and validation established by government standards. The subsystem is defined as the ballast, igniter and light source and shall be tested as a subsystem and considered one test sample for the entire test sequence. A failure of any component in the test sample shall constitute a failure of the entire sample. Substitution or replacement of only the light source shall be allowed during testing.
Standard

SPECIFICATION FOR TESTING GAS DISCHARGE LIGHT SOURCE SUBSYSTEM

2007-10-08
USCAR27
This specification is a general level subsystem light source specification that establishes test requirements of a Gas Discharge Light Source (GDLS) subsystem for use on passenger vehicles. The completed test data to this test specification is intended to be provided to the OEM by the Tier one lamp set maker as part of the lamp assembly PPAP. Re-testing shall be required if any portion of the approved GDLS experiences a design, manufacturing or component change. This document shall be applied to systems that meet the requirements for design, performance and validation established by government standards. The subsystem is defined as the ballast, igniter and light source and shall be tested as a subsystem and considered one test sample for the entire test sequence. A failure of any component in the test sample shall constitute a failure of the entire sample. Substitution or replacement of only the light source shall be allowed during testing.
Standard

Ergonomic Guidelines for Small Lot Delivery Operations

2015-03-10
USCAR42
This document describes the design, assessment methods and physical requirements associated with material handling systems. This would include, but not limited to manual dollies, small lot systems and kitting. All possible designs and applications could not be anticipated in creating these guidelines. Where there are questions of adherence to this document, such as use of an “off-the shelf” design, always consult the responsible Ergonomics Department.
Standard

STANDARD FOR CIGAR LIGHTERS & POWER OUTLETS

1998-09-01
USCAR4
This standard is intended to cover cigar or cigarette lighters as well as power outlets based on the form and dimensions of the cigar lighter. This standard is a full performance specification, it includes dimensional and operational parameters as well as performance characteristics which must be met when submitting a cigar lighter assembly or power outlet assembly for production approval. This standard constitutes an acceptance specification for a surface mounted, front-loaded cigar lighter or power outlet.
Standard

Standard for Cigar Lighters & Power Outlets

2014-03-31
USCAR4-1
This standard is intended to cover cigar or cigarette lighters as well as power outlets based on the form and dimensions of the cigar lighter. This standard is a full performance specification, it includes dimensional and operational parameters as well as performance characteristics which must be met when submitting a cigar lighter assembly or power outlet assembly for production approval. This standard constitutes an acceptance specification for a surface mounted, front-loaded cigar lighter or power outlet.
Standard

FIELD CORRELATED LIFE TEST SUPPLEMENT TO SAE/USCAR-2

2001-12-01
USCAR20
This life test for underhood/passenger/trunk connector systems may be used in place of Section 5.8.6 (Connector System Electrical Test Flow Chart) of SAE/USCAR-2. All other requirements of SAE/USCAR-2 remain applicable even when this test is used. Refer to SAE/USCAR-2 and Connector/Terminal Supplier for appropriate power rating and current cycle Testing.
Standard

FIELD CORRELATED LIFE TEST SUPPLEMENT TO SAE/USCAR-2

2022-03-15
USCAR20-2
This life test for underhood/passenger/trunk connector systems may be used in place of Section 5.9.6, Connection System Electrical Table of SAE/USCAR-2. All other requirements of SAE/USCAR-2 remain applicable even when this test is used. Refer to SAE/USCAR-2 and Connector/Terminal Supplier for appropriate power rating and current cycle Testing.
Standard

FIELD CORRELATED LIFE TEST SUPPLEMENT TO SAE/USCAR-2

2004-06-23
USCAR20-1
This life test for underhood/passenger/trunk connector systems may be used in place of Section 5.9.6, Connection System Electrical Table of SAE/USCAR-2. All other requirements of SAE/USCAR-2 remain applicable even when this test is used. Refer to SAE/USCAR-2 and Connector/Terminal Supplier for appropriate power rating and current cycle Testing.
Standard

SPECIFICATION FOR TESTING AUTOMOTIVE MINIATURE BULBS

2022-03-15
USCAR3-4
The procedures contained in this specification cover the laboratory testing of miniature incandescent bulbs for use in automotive illumination and signaling applications. The following tests shall be run whenever the following occurs: New bulb design Design or process change made to an existing bulb, which could affect the outcome of the test. The completion of one calendar year as noted in the following Test Schedule Table. Process control data is acceptable.
Standard

SPECIFICATION FOR TESTING AUTOMOTIVE MINIATURE BULBS

2009-12-01
USCAR3-3
The procedures contained in this specification cover the laboratory testing of miniature incandescent bulbs for use in automotive illumination and signaling applications. The following tests shall be run whenever the following occurs: New bulb design Design or process change made to an existing bulb, which could affect the outcome of the test. The completion of one calendar year as noted in the following Test Schedule Table. Process control data is acceptable.
Standard

STANDARD FOR IN-TANK ELECTRIC FUEL PUMPS

1999-08-15
USCAR13
This standard covers the operational characteristics, environment, durability procedures, and test procedures for in-tank electric fuel pumps for automotive gasoline applications. Specific performance and test criteria used in conjunction with this procedure are specified on the pump drawing. Particular sections of this document may be required for all applications. This standard is intended to evaluate specific characteristics as a supplement to normal material inspections, dimensional checking, and in-process controls, and should in no way adversely influence other inspection operations.
Standard

TEST PROCEDURE FOR ELECTRICAL GROUND ATTACHMENTS

2022-02-25
USCAR26
This test procedure is intended to evaluate and/or validate electrical ground schemes for use on the body or chassis. There are two classes based on the expected environmental conditions. Exposed Grounds can be located anywhere in the vehicle (except on the powertrain) and is the class for which most schemes should be tested. Unexposed Grounds can only be used in the passenger compartment or trunk and as such are special cases. This procedure as written is not intended for testing powertrain grounds where high temperatures and vibration levels may be encountered. These situations may require modifications to this procedure and are left to the Responsible Engineer to determine. This specification does not specifically address validation of terminal to wire electrical crimps. Crimps are tested to SAE/USCAR-21
Standard

Specification for Testing Automotive Halogen Light Sources

2006-01-01
USCAR14-2
The procedures contained in this specification cover the laboratory testing of replaceable halogen incandescent bulbs for use in automotive road illumination. The following tests are intended to be run under the following conditions. New bulb design Design or process change made to an existing bulb, which could affect the outcome of the test The completion of one calendar year, accept as noted in the following Test Schedule Table. Test Title Yearly Physical Dimensions X Mean Spherical Candela (MSCD) X External Visual Examination X Color X Leak/Sealability Through Terminals and Seals X Deflection X Fluid Compatibility Terminal Retention X Resonant Frequencies Aged Resonant Frequency Salt Spray Outgassing Temperatures Requirement Laboratory Life at 14.0 VDC X Luminous Intensity Maintenance X Vibration Durability Shock Aged Vibration Durability Terminal Requirements DRL (SAE J2087)
Standard

SPECIFICATION FOR TESTING AUTOMOTIVE HALOGEN LIGHT SOURCES

2022-03-15
USCAR14-3
The procedures contained in this specification cover the laboratory testing of replaceable halogen incandescent bulbs for use in automotive road illumination. The following tests are intended to be run under the following conditions. New bulb design Design or process change made to an existing bulb, which could affect the outcome of the test The completion of one calendar year, accept as noted in the following Test Schedule Table. Test Title Yearly Physical Dimensions X Mean Spherical Candela (MSCD) X External Visual Examination X Color X Leak/Sealability Through Terminals and Seals X Deflection X Fluid Compatibility Terminal Retention X Resonant Frequencies Aged Resonant Frequency Salt Spray Outgassing Temperatures Requirement Laboratory Life at 14.0 VDC X Luminous Intensity Maintenance X Vibration Durability Shock Aged Vibration Durability Terminal Requirements DRL (SAE J2087)
X