Refine Your Search

Topic

Search Results

Standard

Sensitization and Corrosion in Stainless Steel Filters

1995-11-01
HISTORICAL
AIR844A
This document reviews briefly the subject of woven metal screens. Conditions that can promote damaging corrosion in stainless steel filter screens are discussed and recommendations are listed for minimizing corrosion damage. This is a general document only; for specific applications it is suggested that the reader refer to the technical literature, and selected references listed below.
Standard

Sensitization and Corrosion in Stainless Steel Filters

2014-02-06
CURRENT
AIR844B
This document reviews briefly the subject of woven metal screens. Conditions that can promote damaging corrosion in stainless steel filter screens are discussed and recommendations are listed for minimizing corrosion damage. This is a general document only; for specific applications it is suggested that the reader refer to the technical literature, and selected references listed below.
Standard

Aerospace - Particle Count Data Conversion and Extrapolation

1993-01-01
HISTORICAL
AIR877
This Aerospace Information Report (AIR) describes a mathematical model that can be used to analyze particle count data. Particle counts that fit the model can be graphically displayed, converted from one counting size-frequency range to another, and extrapolated to estimate counts beyond the measured range. Derivation, applications and calculations are described. Cumulative particle counts larger than stated size-range are fitted against a modified log-normal distribution function by plotting on special log-log graph paper. Many real particle distributions approximate a straight line, showing good fit for this log-normal model. The resultant plot provides a basis for further analysis, including size-range conversion and extrapolation.
Standard

AEROSPACE-PARTICLE COUNT DATA CONVERSION AND EXTRAPOLATION

1993-03-02
HISTORICAL
AIR877A
This Aerospace Information Report (AIR) describes a mathematical model that can be used to analyze particle count data. Particle counts that fit the model can be graphically displayed, converted from one counting size-frequency range to another, and extrapolated to estimate counts beyond the measured range. Derivation, applications and calculations are described.
Standard

Aerospace-Particle Count Data Conversion and Extrapolation

1993-03-02
HISTORICAL
AIR877B
This SAE Aerospace Information Report (AIR) describes a mathematical model that can be used to analyze particle count data. Particle counts that fit the model can be graphically displayed, converted from one counting size-frequency range to another, and extrapolated to estimate counts beyond the measured range. Derivation, applications, and calculations are described.
Standard

Aerospace-Particle Count Data Conversion and Extrapolation

2012-09-24
CURRENT
AIR877C
This SAE Aerospace Information Report (AIR) describes a mathematical model that can be used to analyze particle count data. Particle counts that fit the model can be graphically displayed, converted from one counting size-frequency range to another, and extrapolated to estimate counts beyond the measured range. Derivation, applications, and calculations are described.
Standard

Secondary Filters for Fluid System Reliability

2000-12-01
HISTORICAL
AIR4057A
This SAE Aerospace Information Report (AIR) discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

SECONDARY FILTERS FOR FLUID SYSTEM RELIABILITY

1994-05-01
HISTORICAL
AIR4057
It discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

Secondary Filters for Fluid System Reliability

2012-09-24
CURRENT
AIR4057B
This SAE Aerospace Information Report (AIR) discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

Evaluating Effectiveness of Filter Element Cleaning Methods

2014-06-03
CURRENT
ARP725B
This SAE Aerospace Recommended Practice (ARP) presents a procedure for evaluating cleaning methods with respect to contaminant removal and element degradation particularly for metallic filter elements. A procedure for checking durability of cleaning equipment and a referee cleaning method are also included. It is applicable only to the evaluation of cleaning methods proposed for removal of service dirt and not for built-in dirt, liquid oxygen (LOX) cleaning, etc. Supporting information for use with the ARP is also included.
Standard

Evaluating Effectiveness of Filter Element Cleaning Methods

2003-06-05
HISTORICAL
ARP725A
This SAE Aerospace Recommended Practice (ARP) presents a procedure for evaluating cleaning methods with respect to contaminant removal and element degradation particularly for metallic filter elements. A procedure for checking durability of cleaning equipment and a referee cleaning method are also included. It is applicable only to the evaluation of cleaning methods proposed for removal of service dirt and not for built-in dirt, liquid oxygen (LOX) cleaning, etc. Supporting information for use with the ARP is also included.
Standard

METHODS FOR EVALUATING CRYOGENIC FILTERS

1975-07-01
HISTORICAL
ARP900
The purpose of this test procedure is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters up to and including 60 GPM (330 liters per minute) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system.
Standard

Methods for Evaluating Cryogenic Filters

2017-08-15
WIP
ARP900C
The purpose of this test procedure is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters up to and including 60 gpm (230 lpm) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system. The test methods presented herein do not encompass testing of cryogenic bypass relief valves, delta P indicators, gages, or components other than a basic filter housing and element.
Standard

Methods for Evaluating Cryogenic Filters

2011-12-19
CURRENT
ARP900B
The purpose of this document is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters for particle sizes equal to or greater than 5.0 μm and flows up to and including 60 gpm (230 L/min) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system from those recommended in this document.
Standard

Methods for Evaluating Cryogenic Filters

1992-06-29
HISTORICAL
ARP900A
The purpose of this test procedure is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters up to and including 60 gpm (230 lpm) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system.