Refine Your Search

Topic

Search Results

Standard

Laboratory Testing of Light Duty Vehicle Electric Cooling Fan Assemblies for Airflow Performance

2014-08-28
HISTORICAL
J2867_201408
This SAE Recommended Practice is intended for use in testing and evaluating the performance of Light Duty automotive electric engine cooling fans. These Electric Cooling Fan (ECF) Assemblies are purchased by Light Duty Truck and Passenger Car OEM’s from suppliers. They are purchased as complete assemblies, consisting of the fan(s), motor(s), and shroud (see Figure 1); this Recommended Practice will only consider such complete assemblies. Some purchased assemblies using brush-type motors may also include control devices such as power resistors or pulse width modulation (PWM) electronics for speed control. In the case of brushless motor technology, the controller is an integral part of the motor where it also performs the commutation process electronically. The performance measurement would include fan output in terms of airflow and pressure, and fan input electric power in terms of voltage and current.
Standard

Laboratory Testing of Light-Duty Vehicle Electric Cooling Fan Assemblies for Airflow Performance

2019-02-13
CURRENT
J2867_201902
This SAE recommended practice is intended for use in testing and evaluating the performance of light-duty automotive electric engine cooling fan assemblies. These Electric Cooling Fan (ECF) assemblies are purchased by light-duty truck and passenger car OEMs from suppliers. They are purchased as complete assemblies, consisting mainly of the fan(s), motor(s), and shroud (see Figure 1); this Recommended Practice will only consider such complete assemblies. Some purchased assemblies using brush-type motors may also include digital control devices such as power resistors or pulse width modulation (PWM) electronics or local interconnect network (LIN) for speed control. In the case of brushless motor technology, the controller is an integral part of the motor where it also performs the commutation process electronically. The performance measurement would include fan output in terms of airflow and pressure, and fan input electric power in terms of voltage and current.
Standard

Exhaust Gas Recirculation (EGR) Cooler Nomenclature and Application

2011-11-02
HISTORICAL
J2914_201111
This document provides an overview on how and why EGR coolers are utilized, defines commonly used nomenclature, discusses design issues and trade-offs, and identifies common failure modes. The reintroduction of exhaust gas into the combustion chamber is just one component of the emission control strategy for internal combustion (IC) engines, both diesel and gasoline, and is useful in reducing exhaust port emission of Nitrogen Oxides (NOx). Other means of reducing NOx exhaust port emissions are briefly mentioned, but beyond the scope of this document.
Standard

Exhaust Gas Recirculation (EGR) Cooler Nomenclature and Application

2022-11-22
CURRENT
J2914_202211
This document provides an overview on how and why EGR coolers are utilized, defines commonly used nomenclature, discusses design issues and trade-offs, and identifies common failure modes. The reintroduction of selectively cooled exhaust gas into the combustion chamber is just one component of the emission control strategy for internal combustion (IC) engines, both diesel and gasoline, and is useful in reducing exhaust port emission of nitrogen oxides (NOx). Other means of reducing NOx exhaust port emissions are briefly mentioned, but beyond the scope of this document.
Standard

HEAVY DUTY NON-METALLIC ENGINE COOLING FANS—MATERIAL, MANUFACTURING AND TEST CONSIDERATIONS

1985-01-01
HISTORICAL
J1474_198501
All materials classified as nylons share certain basic characteristics. However, even within the seemingly limited realm of glass fiber reinforced nylons, many levels and combinations of physical, thermal, and environmental resistance properties are available. These properties result from such factors as the following: 1 Type of nylon (6, 6/6, 6/10, 6/12, etc.) 2 Percentage (by weight) of glass fibers 3 Diameter and length of glass fibers 4 Wetting agent used to promote adhesion between resin and fibers (if present) 5 Heat stabilizer (if present) 6 Impact modifier (if present) 7 Pigmentation (if present) In order to select a material with appropriate characteristics, the prospective manufacturer and end user should investigate the proposed application thoroughly, and maintain open communication with the various material suppliers.
Standard

HEAVY-DUTY NONMETALLIC ENGINE COOLING FANS—MATERIAL, MANUFACTURING, AND TEST CONSIDERATIONS

1995-06-01
HISTORICAL
J1474_199506
The following topics are included in this report: Section 2—References Section 3—Definitions Section 4—Material Selection Section 5—Production Considerations Section 6—Initial Structural Integrity Section 7—In-Vehicle Testing Section 8—Laboratory Testing The Material Selection section lists environmental factors and material properties which should be considered when determining appropriate fan material(s) for a given application. The Production Considerations section covers various aspects of machine selection, mold design, and process control. The Initial Structural Integrity section lists factors which should be considered in addition to those covered by Section 3 of SAE J1390. The In-Vehicle Testing section lists factors which should be considered in addition to those covered by Section 4 of SAE J1390.
Standard

Heavy-Duty Nonmetallic Engine Cooling Fans—Material, Manufacturing, and Test Considerations

2003-04-25
HISTORICAL
J1474_200304
The following topics are included in this report: Section 2—References Section 3—Definitions Section 4—Material Selection Section 5—Production Considerations Section 6—Initial Structural Integrity Section 7—In-Vehicle Testing Section 8—Laboratory Testing The Material Selection section lists environmental factors and material properties which should be considered when determining appropriate fan material(s) for a given application. The Production Considerations section covers various aspects of machine selection, mold design, and process control. The Initial Structural Integrity section lists factors which should be considered in addition to those covered by Section 3 of SAE J1390. The In-Vehicle Testing section lists factors which should be considered in addition to those covered by Section 4 of SAE J1390.
Standard

Heavy-Duty Nonmetallic Engine Cooling Fans—Material, Manufacturing, and Test Considerations

2009-12-14
HISTORICAL
J1474_200912
The following topics are included in this report: Section 2—References Section 3—Definitions Section 4—Material Selection Section 5—Production Considerations Section 6—Initial Structural Integrity Section 7—In-Vehicle Testing Section 8—Laboratory Testing The Material Selection section lists environmental factors and material properties which should be considered when determining appropriate fan material(s) for a given application. The Production Considerations section covers various aspects of machine selection, mold design, and process control. The Initial Structural Integrity section lists factors which should be considered in addition to those covered by the same section of SAE J1390. The In-Vehicle Testing section lists factors which should be considered in addition to those covered by the same section of SAE J1390.
Standard

APPLICATION TESTING OF OIL-TO-AIR OIL COOLERS FOR COOLING PERFORMANCE

1993-05-20
HISTORICAL
J1468_199305
This SAE Recommended Practice is applicable to oil-to-air oil coolers installed on mobile or stationary equipment. This document outlines the method of procuring the test data to determine operating characteristics of the oil cooling system and the interpretation of the test results.
Standard

APPLICATION TESTING OF OIL TO AIR OIL COOLERS FOR COOLING PERFORMANCE

1985-11-01
HISTORICAL
J1468_198511
This Recommended Practice is applicable to oil to air oil coolers installed on mobile or stationary equipment. This document outlines the method of procuring the test data to determine operating characteristics of the oil cooling system and the interpretation of the test results.
Standard

Fan Hub Bolt Circles and Pilot Holes

2014-03-12
HISTORICAL
J635_201403
This Recommended Practice applies to engine cooling fans up to 2000 mm in diameter with a mounting interface consisting of a pilot hole and a circular bolt pattern. Most of these fans are belt, gear, clutch, hydraulically, or electrically driven.
Standard

Fan Hub Bolt Circles and Pilot Holes

2018-06-02
CURRENT
J635_201806
This Recommended Practice applies to engine cooling fans up to 2000 mm in diameter with a mounting interface consisting of a pilot hole and a circular bolt pattern. Most of these fans are belt, gear, clutch, hydraulically, or electrically driven.
Standard

Thermal Flow Control Valve Nomenclature and Application

2018-11-02
CURRENT
J3142_201811
The purpose of this SAE Information Report is to define common industry terminology and nomenclature relative to thermal flow control valves and to describe common thermal flow control valve applications in automotive, highway truck, mobile construction equipment, and industrial applications. This document is primarily directed at internal combustion engine or electric powered applications and the downstream systems to which power is provided, such as transmissions, hydraulics, air compression, etc. The information contained herein does not constitute an SAE Standard.
Standard

Radiator Caps and Filler Necks

2011-03-22
HISTORICAL
J164_201103
This SAE Standard was developed primarily for passenger car and truck application, but may be used in marine, industrial, and similar applications.
Standard

Radiator Caps and Filler Necks

2005-02-07
HISTORICAL
J164_200502
This SAE Standard was developed primarily for passenger car and truck application, but may be used in marine, industrial, and similar applications.
Standard

RADIATOR CAPS AND FILLER NECKS

1997-02-01
HISTORICAL
J164_199702
This SAE Standard was developed primarily for passenger car and truck application, but may be used in marine, industrial, and similar applications.
X