Refine Your Search

Topic

Search Results

Standard

Type "F" Clamps for Plumbing Applications

2008-12-02
HISTORICAL
J1670_200812
This SAE Standard covers complete dimensional and general specifications for worm drive hose clamps for general use in the plumbing industry.
Standard

Test Method for Evaluating the Electrochemical Resistance of Coolant System Hoses and Materials

2005-09-12
HISTORICAL
J1684_200509
This test method provides a standardized procedure for evaluating the electrochemical resistance of automotive coolant hose and materials. Electrochemical degradation has been determined to be a major cause of EPDM coolant system hose failures. The test method consists of a procedure which induces voltage to a test specimen while it is exposed to a water/coolant solution. Method #1, referred to as a “Brabolyzer” test, is a whole hose test. Method #2, referred to as a “U” tube test, uses cured plate samples or plates prepared from tube material removed from hose (Method No. 2 is intended as a screening test only). Any test parameters other than those specified in this SAE Recommended Practice, are to be agreed to by the tester and the requester.
Standard

Test Method for Evaluating the Electrochemical Resistance of Coolant System Hoses and Materials

2018-11-21
CURRENT
J1684_201811
This test method provides a standardized procedure for evaluating the electrochemical resistance of automotive coolant hose and materials. Electrochemical degradation has been determined to be a major cause of EPDM coolant system hose failures. The test method consists of a procedure which induces voltage to a test specimen while it is exposed to a water/coolant solution. Method #1, referred to as a “Brabolyzer” test, is a whole hose test. Method #2, referred to as a “U” tube test, uses cured plate samples or plates prepared from tube material removed from hose (Method No. 2 is intended as a screening test only). Any test parameters other than those specified in this SAE Recommended Practice, are to be agreed to by the tester and the requester.
Standard

Recommended Practices for Design and Evaluation of Passenger and Light Truck Coolant Hose Clamped Joints

2013-07-09
CURRENT
J1697_201307
This SAE Recommended Practice covers recommended practices for design and evaluation of hose clamped joints primarily in automotive applications. It is intended to: (a) evaluate current joint designs, (b) compare existing designs, (c) aid in the development of new designs, (d) give objective results once weights are set, (e) rate the overall design and individual sections of design, and (f) encourage future research by industry and the OEM's.
Standard

Compression Set of Hoses or Solid Discs

2004-11-30
HISTORICAL
J1638_200411
This SAE Recommended Practice is used for establishing the compression set that could be expected to occur with a thermoset elastomeric hose under securing clamps. It seeks to reproduce the type of indentation caused by the clamps in the wall of a hose. An excessive compression set measured by this method may indicate a hose that could eventually allow leakage of fluid or gas past the clamps in service.
Standard

Compression Set of Hoses or Solid Discs

2015-04-21
CURRENT
J1638_201504
This SAE Recommended Practice is used for establishing the compression set that could be expected to occur with a thermoset elastomeric hose under securing clamps. It seeks to reproduce the type of indentation caused by the clamps in the wall of a hose. An excessive compression set measured by this method may indicate a hose that could eventually allow leakage of fluid or gas past the clamps in service.
Standard

COMPRESSION SET OF HOSES OR SOLID DISCS

1993-05-01
HISTORICAL
J1638_199305
This SAE Recommended Practice is used for establishing the compression set that could be expected to occur with engine coolant hoses under securing clamps. It seeks to reproduce the type of indentation caused by the clamps in the wall of the hose. An excessive compression set measured by this method would indicate a hose that could eventually allow leakage of coolant past the clamps in service. This method has been found to give repeatable results in the range of 25% to 50% initial compression.
Standard

Test Method for Evaluating the Sealing Capability of Hose Connections with a PVT Test Facility

2012-10-24
CURRENT
J1610_201210
This test method provides a standardized procedure for evaluating the sealing capability of a hose connection or any of the individual components of the connection with a pressure, vibration, and temperature (PVT) test facility. This test method consists of a test procedure which includes vibration and coolant flow (#1 ) and a similar test procedure specified without vibration or coolant flow (#2). Any test parameters, other than those specified in this SAE Recommended Practice, are to be agreed to by the tester and the requestor.
Standard

Hose Clamp Specifications

2023-01-13
CURRENT
J1508_202301
This SAE Standard covers 32 types of clamps most commonly and suitably being used on OEM coolant, fuel, oil, vacuum, and emission systems.
Standard

Hose Clamp Specifications

2009-03-06
HISTORICAL
J1508_200903
This SAE Standard covers thirty-two (32) types of clamps most commonly and suitably being used on OEM coolant, fuel, oil, vacuum, and emission systems.
Standard

AUTOMOTIVE AIR CONDITIONING HOSE

1988-07-01
HISTORICAL
J51_198807
This specification covers reinforced rubber and reinforced thermoplastic hose, or hose assemblies, intended for conducting liquid and gaseous dichlorodifluoromethane (refrigerant 12) in automotive air conditioning systems. The hose shall be designed to minimize permeation of refrigerant 12 and contamination of the system and to be serviceable over a temperature range of -30 to 120°C (-22 to 248°F). Specific construction details are to be agreed upon between user and supplier.
Standard

AUTOMOTIVE AIR CONDITIONING HOSE

1985-05-01
HISTORICAL
J51_198505
This specification covers reinforced rubber and reinforced thermoplastic hose, or hose assemblies, intended for conducting liquid and gaseous dichlorodifluoromethane (refrigerant 12) in automotive air conditioning systems. The hose shall be designed to minimize permeation of refrigerant 12 and contamination of the system and to be serviceable over a temperature range of −30 to 120°C (−22 to 248°F). Specific construction details are to be agreed upon between user and supplier.
Standard

Refrigerant 12 Automotive Air-Conditioning Hose

1998-08-01
HISTORICAL
J51_199808
This SAE Standard covers reinforced hose, or hose assemblies, intended for conducting liquid and gaseous dichlorodifluoromethane (refrigerant 12) in automotive air-conditioning systems. The hose shall be designed to minimize permeation of refrigerant 12 and contamination of the system and to be serviceable over a temperature range of −30 to 120 °C (−22 to 248 °F). Specific construction details are to be agreed upon between user and supplier.1
Standard

AUTOMOTIVE AIR-CONDITIONING HOSE

1989-05-01
HISTORICAL
J51_198905
This specification covers reinforced rubber and reinforced thermoplastic hose, or hose assemblies, intended for conducting liquid and gaseous dichlorodifluoromethane (refrigerant 12) in automotive air-conditioning systems. The hose shall be designed to minimize permeation of refrigerant 12 and contamination of the system and to be serviceable over a temperature range of -30 to 120°C (-22 to 248°F). Specific construction details are to be agreed upon between user and supplier.
Standard

Refrigerant 12 Automotive Air-Conditioning Hose

2004-06-14
HISTORICAL
J51_200406
This SAE Standard covers reinforced hose, or hose assemblies, intended for conducting liquid and gaseous dichlorodifluoromethane (refrigerant 12) in automotive air-conditioning systems. The hose shall be designed to minimize permeation of refrigerant 12 and contamination of the system and to be serviceable over a temperature range of −30 to 120 °C (−22 to 248 °F). Specific construction details are to be agreed upon between user and supplier.1
Standard

Refrigerant 12 Automotive Air-Conditioning Hose

2015-04-21
CURRENT
J51_201504
This SAE Standard covers reinforced hose, or hose assemblies, intended for conducting liquid and gaseous dichlorodifluoromethane (refrigerant 12) in automotive air-conditioning systems. The hose shall be designed to minimize permeation of refrigerant 12 and contamination of the system and to be serviceable over a temperature range of −30 to 120 °C (−22 to 248 °F). Specific construction details are to be agreed upon between user and supplier.1 NOTE—R12 refrigerant has been placed on a banned substance list due to its ozone depletion characteristics. SAE J51 specification will be phased out as new automotive A/C systems are using R134a. SAE J2064 is the Standard for refrigerant 134a hose. For refrigerant 134a use, refer to SAE J2064.
Standard

FUEL AND OIL HOSES

1985-06-01
HISTORICAL
J30_198506
This specification covers three types of fuel and oil hose, coupled and uncoupled, for use with gasoline oil and diesel fuel.
Standard

FUEL AND OIL HOSES

1991-06-01
HISTORICAL
J30_199106
This SAE Standard covers fuel and oil hose, coupled and uncoupled, for use with gasoline, oil, diesel fuel, lubrication oil, or the vapor present in either the fuel system or in the crankcase of internal combustion engines in mobile, stationary, and marine applications. Section 7 covers hose primarily intended to meet the demands of fuel injection systems. Section 3 covers Coupled and Uncoupled Synthetic Rubber Tube and Cover (SAE 30R2). Section 4 covers Lightweight Braided Reinforced Lacquer, Cement, or Rubber Covered Hose (SAE 30R3). Section 5 covers Wire Inserted Synthetic Rubber Tube and Cover (SAE 30R5). Section 6 covers Low Pressure Coupled and Uncoupled Synthetic Rubber Tube and Cover (SAE 30R6), (SAE 30R7), (SAE 30R8). Section 7 covers Fuel Injection Hose Medium Pressure Coupled and Uncoupled Synthetic Rubber Tube and Cover (SAE 30R9). Section 8 covers In-Tank, Low Pressure, Uncoupled Fuel Hoses (SAE 30R10).
Standard

FUEL AND OIL HOSES

1993-05-01
HISTORICAL
J30_199305
This SAE Standard covers fuel and oil hose, coupled and uncoupled, for use with gasoline, oil, diesel fuel, lubrication oil, or the vapor present in either the fuel system or in the crankcase of internal combustion engines in mobile, stationary, and marine applications. Section 7 covers hose primarily intended to meet the demands of fuel injection systems. Section 3 covers Coupled and Uncoupled Synthetic Rubber Tube and Cover (SAE 30R2). Section 4 covers Lightweight Braided Reinforced Lacquer, Cement, or Rubber Covered Hose (SAE 30R3). Section 5 covers Wire Inserted Synthetic Rubber Tube and Cover (SAE 30R5). Section 6 covers Low-Pressure Coupled and Uncoupled Synthetic Rubber Tube and Cover (SAE 30R6), (SAE 30R7), (SAE 30R8). Section 7 covers Fuel Injection Hose Medium-Pressure Coupled and Uncoupled Synthetic Rubber Tube and Cover (SAE 30R9). Section 8 covers In-Tank, Low-Pressure, Uncoupled Fuel Hoses (SAE 30R10). Section 9 covers Unified Method for Fuel Hose Permeation.
X