Refine Your Search

Search Results

Journal Article

Experimental Investigation of Different Blends of Diesel and Gasoline (Dieseline) in a CI Engine

2014-10-13
2014-01-2686
Combustion behaviour and emissions characteristics of different blending ratios of diesel and gasoline fuels (Dieseline) were investigated in a light-duty 4-cylinder compression-ignition (CI) engine operating on partially premixed compression ignition (PPCI) mode. Experiments show that increasing volatility and reducing cetane number of fuels can help promote PPCI and consequently reduce particulate matter (PM) emissions while oxides of nitrogen (NOx) emissions reduction depends on the engine load. Three different blends, 0% (G0), 20% (G20) and 50% (G50) of gasoline mixed with diesel by volume, were studied and results were compared to the diesel-baseline with the same combustion phasing for all experiments. Engine speed was fixed at 1800rpm, while the engine load was varied from 1.38 to 7.85 bar BMEP with the exhaust gas recirculation (EGR) application.
Technical Paper

Research on Steady and Transient Performance of an HCCI Engine with Gasoline Direct Injection

2008-06-23
2008-01-1723
In this paper, a hybrid combustion mode in four-stroke gasoline direct injection engines was studied. Switching cam profiles and injection strategies simultaneously was adopted to obtain a rapid and smooth switch between SI mode and HCCI mode. Based on the continuous pressure traces and corresponding emissions, HCCI steady operation, HCCI transient process (combustion phase adjustment, SI-HCCI, HCCI-SI, HCCI cold start) were studied. In HCCI mode, HCCI combustion phase can be adjusted rapidly by changing the split injection ratio. The HCCI control strategies had been demonstrated in a Chery GDI2.0 engine. The HCCI engine simulation results show that, oxygen and active radicals are stored due to negative valve overlap and split fuel injection under learn burn condition. This reduces the HCCI sensitivity on inlet boundary conditions, such as intake charge and intake temperature. The engine can be run from 1500rpm to 4000rpm in HCCI mode without spark ignition.
Technical Paper

Homogeneous Charge Combustion and Emissions of Ethanol Ignited by Pilot Diesel on Diesel Engines

2004-03-08
2004-01-0094
Homogeneous charge combustion and emissions of ethanol ignited by pilot diesel fuel were investigated on a two-cylinder diesel engine. The results show that emissions depend on loads and ethanol volume fraction. At low loads, ethanol has little effects on smoke. With the increase of ethanol, NOx decreases, but CO emissions increase. At high loads, smoke emissions reduce greatly with increasing ethanol, but NOx and total hydrocarbon (THC) emissions increase. With the increase of ethanol, ignition delays, combustion duration shortens. The maximum rates of heat release for the fuel containing 10 vol% ethanol (E10) and 30 vol% ethanol (E30) increase. Brake specific energy consumption (BSEC) of E10 and E30 is improved slightly only at full loads. Compared to smoke emissions obtained on the same engine using ethanol blended diesel fuels, the tendency of smoke reduction is similar to that of homogeneous charge combustion of ethanol at the same operating conditions.
Technical Paper

PIV Measurement and Numerical Simulation of Flows in Automotive Catalytic Converters

2001-09-24
2001-01-3494
In this paper a Particle Image Velocimetry (PIV) was used to measure flow velocity fields in different inlet cones under different mass flux conditions on a steady state flow rig. Meanwhile, a mathematical model of the flow in catalytic converters was established and simulated using CFD code. Validation of the model shows that simulation results have a good agreement with experiments, which means that the established model is feasible and can be applied to predict the flow characteristics in catalytic converters with different inlet cone configurations. Experimental and computational results indicate that the inlet cone configuration significantly affects flow distribution. For a conventional inlet cone, the cone angle is one of the key factors to affect flow characteristics and should be kept as small as possible in a design. An enhanced inlet cone can greatly improve flow uniformity in catalytic converters.
Technical Paper

Experiment and Numerical Simulation of Unsteady Temperature Fields in Automotive Catalytic Converters

2001-09-24
2001-01-3563
This paper measured unsteady temperature fields of uncoated-monolith and catalytic monolith under real engine operating conditions using thermocouples. A multi-dimensional flow mathematical model of the turbulence, heat and mass transfer, and chemical reactions in monoliths was established using a computational fluid dynamics (CFD) code and numerically solved in the whole flow field of the catalytic converter. The purpose of this paper is to study unsteady warm-up characteristics of the monoliths and to investigate effects of inlet cone structure on temperature distribution of the catalytic converter. Experimental results show that the warm-up behaviors between uncoated-monolith and catalytic monolith are quite different. Simulation results indicate that the established model can qualitatively predict the warm-up characteristics.
Technical Paper

Simulation of Catalyzed Diesel Particulate Filter for Active Regeneration Process Using Secondary Fuel Injection

2017-10-08
2017-01-2287
Advanced exhaust after-treatment technology is required for heavy-duty diesel vehicles to achieve stringent Euro VI emission standards. Diesel particulate filter (DPF) is the most efficient system that is used to trap the particulate matter (PM), and particulate number (PN) emissions form diesel engines. The after-treatment system used in this study is catalyzed DPF (CDPF) downstream of diesel oxidation catalyst (DOC) with secondary fuel injection. Additional fuel is injected upstream of DOC to enhance exothermal heat which is needed to raise the CDPF temperature during the active regeneration process. The objective of this research is to numerically investigate soot loading and active regeneration of a CDPF on a heavy-duty diesel engine. In order to improve the active regeneration performance of CDPF, several factors are investigated in the study such as the effect of catalytic in filter wall, soot distribution form along filter wall, and soot loads.
Technical Paper

Development of Model Based Closed Loop Control Strategy of SCR System for Heavy-Duty Diesel Engines

2017-10-08
2017-01-2383
Urea selective catalytic reduction (SCR) is a key technology for heavy-duty diesel engines to meet the increasingly stringent nitric oxides (NOx) emission limits of regulations. The urea water solution injection control is critical for urea SCR systems to achieve high NOx conversion efficiency while keeping the ammonia (NH3) slip at a required level. In general, an open loop control strategy is sufficient for SCR systems to satisfy Euro IV and Euro V NOx emission limits. However, for Euro VI emission regulation, advanced control strategy is essential for SCR systems due to its more tightened NOx emission limit and more severe test procedure compared to Euro IV and Euro V. This work proposed an approach to achieve model based closed loop control for SCR systems to meet the Euro VI NOx emission limits. A chemical kinetic model of the SCR catalyst was established and validated to estimate the ammonia storage in the SCR catalyst.
Technical Paper

Combustion and Emission Characteristics of a PPCI Engine Fuelled with Dieseline

2012-04-16
2012-01-1138
In this paper blends of diesel and gasoline (dieseline) fuelled Partially Premixed Compression Ignition (PPCI) combustion and the comparison to conventional diesel combustion is investigated. The tests are carried out using a light duty four cylinder Euro IV diesel engine. The engine condition is maintained at 1800 rpm, 52 Nm (equivalent IMEP around 4.3 bar). Different injection timings and different amounts of EGR are used to achieve the PPCI combustion. The results show that compared to the conventional diesel combustion, the smoke and NOx emissions can be reduced by more than 95% simultaneously with dieseline fuelled PPCI combustion. The particle number total concentration can be reduced by 90% as well as the mean diameter (from 54 nm for conventional diesel to 16 nm for G50 fuelled PPCI). The penalty is a slightly increased noise level and lower indicated efficiency, which is decreased from 40% to 38.5%.
Technical Paper

Development of Closed-loop Control Strategy for Urea-SCR Based on NOX Sensors

2011-04-12
2011-01-1324
Selective catalytic reduction (SCR) is a promising technology for diesel aftertreatment used to reduce NOX emission effectively. SCR can be used to meet Euro - and even stricter emission standards. Dosing of urea must be controlled to lower NOX emission and NH₃ slip synchronously under the emission standard limits. A type of closed-loop control strategy based on NOX sensors for SCR system was presented in this paper. To detect NOX emissions, two NOX sensors were installed before and after the catalyst. Meanwhile, to examine the trade-off relationship between NOX emission and NH₃ slip, influences of different control parameters to the control purpose were explored. These influences include space velocity, catalyst temperament, NOX conversion efficiency, NH₃ adsorption and desorption characteristics, and so on. Results were used to optimize the dosing control strategy of urea. Base dosage of urea was confirmed based on the signals of NOX sensor.
Technical Paper

High Efficiency and Low Pollutants Combustion: Gasoline Multiple Premixed Compression Ignition (MPCI)

2012-04-16
2012-01-0382
A new combustion mode namely multiple premixed compression ignition (MPCI) for gasoline engines was proposed. The MPCI mode can be realized by two or more times gasoline injections into cylinder with a high pressure around the compression TDC and featured with a premixed combustion after each injection in the cylinder, which is different from the existed gasoline direct injection compression ignition (GDICI) modes such as homogeneous charge compression ignition (HCCI) mode with gasoline injection occurred in intake stroke, and partially premixed compression ignition (PPCI) mode with multiple gasoline injections in intake and compression strokes before the start of combustion (SOC). Therefore the spray and combustion of the MPCI mode are alternatively occurred as "spray-combustion-spray-combustion" near the TDC, rather than "spray-spray-combustion" sequence as traditional PPCI gasoline engines.
Technical Paper

Comparison Between Air-Assisted and Airless Urea Spray for Diesel SCR System by PDA and CFD

2012-04-16
2012-01-1081
The urea NOx selective catalytic reduction (SCR) is an effective technique for the reduction of NOx emitted from diesel engines. Urea spray quality has significant effect on NOx conversion efficiency. The droplet diameter and velocity distribution of air-assisted and airless urea injection systems were obtained by particle dynamics analyzer (PDA) measurement under different spray injection flow rates. It was found that the atomization quality of air-assisted urea injection system is better than that of airless urea injection system. The penetration and spray cone angle were also investigated by high-speed photography. Especially the spray characteristics of air-assisted urea injection system were measured in the constant-volume-bomb by high-speed photography. The atomization and evaporation of airless urea injection systems were modeled using computational fluid dynamics (CFD) based on the experimental results. The numerical model was validated by the experimental results.
Technical Paper

Numerical Study of Pressure Swirl Spray Using an Improved KIVALES with Dense Grid for GDI Engine

2013-10-14
2013-01-2558
Gasoline direct injection engines can greatly improve the fuel economy, but the idea mixture distribution cannot be easily controlled. In this paper, the linearized instability sheet atomization (LISA) and large eddy simulation (LES) implemented into KIVA-3V code were used to study the gasoline hollow cone spray process for gasoline direct injection (GDI) in a constant volume vessel. The three-dimensional results show that the LISA model can effectively simulate the gasoline hollow cone spray and obtain the string structure compared to the experiment data. And the velocity interpolation method can reduce the grid dependency of spray simulation. Using dense grid (about 8 million cells) in LES and RANS all can obtain the good spray tip penetration and width. Unlike diesel spray, for gasoline spray there are not big difference between the results using LES and RANS. In additional the ambient pressure significantly influence the gasoline spray shape.
Technical Paper

Numerical Study of DMF and Gasoline Spray and Mixture Preparation in a GDI Engine

2013-04-08
2013-01-1592
2, 5-Dimethylfuran (DMF) has been receiving increasing interest as a potential alternative fuel to fossil fuels, owing to the recent development of new production technology. However, the influence of DMF properties on the in-cylinder fuel spray and its evaporation, subsequent combustion processes as well as emission formation in current gasoline direct injection (GDI) engines is still not well understood, due to the lack of comprehensive understanding of its physical and chemical characteristics. To better understand the spray characteristics of DMF and its application to the IC engine, the fuel sprays of DMF and gasoline were investigated by experimental and computational methods. The shadowgraph and Phase Doppler Particle Analyzer (PDPA) techniques were used for measuring spray penetration, droplet velocity and size distribution of both fuels.
Technical Paper

Effects of Spark Ignition and Stratified Charge on Gasoline HCCI Combustion With Direct Injection

2005-04-11
2005-01-0137
HCCI combustion was studied in a 4-stroke gasoline engine with a direct injection system. The electronically controlled two-stage gasoline injection and spark ignition system were adopted to control the mixture formation, ignition timing and combustion rate in HCCI engine. The engine could be operated in HCCI combustion mode in a range of load from 1 to 5 bar IMEP and operated in SI combustion mode up to load of 8 bar IMEP. The HCCI combustion characteristics were investigated under different A/F ratios, engine speeds, starts of injection, as well as spark ignition enabled or not. The test results reveal the HCCI combustion features as a high-pressure gradient after ignition and has advantages in high thermal efficiency and low NOx emissions over SI combustion. At the part load of 1400rpm and IMEP of 3.5bar, ISFC in HCCI mode is 25% lower and NOx emissions is 95% lower than that in SI mode.
Technical Paper

Study of Injection Strategies of Two-stage Gasoline Direct Injection (TSGDI) Combustion System

2005-04-11
2005-01-0107
Gasoline Direct Injection (GDI) engines developed at nineties of the twentieth century can greatly improve the fuel economy. But the combustion chamber design and mixture control of the engines are very complex compared with Port Fuel Injection (PFI) gasoline engines. A two-stage gasoline direct injection (TSGDI) combustion system is developed and aimed to solve the problem of the complexity. Two-stage fuel injection and flexible injection timings are adopted as main means to form reasonable stratified mixture in the cylinder. A simple combustion chamber and helical intake port are designed to assist the mixture's stable combustion, which reduces the difficulties of the combustion system design. Systematical simulation and experimental studies of the effects of injection strategies such as different first,second injection timings and injection ratios, on the mixture formation processes and engine performanc are made in detail.
Technical Paper

Experimental Study and Numerical Interpretation on the Temperature Field of DPF during Active Regeneration with Hydrocarbon Injection

2018-04-03
2018-01-1257
Diesel particulate filter (DPF) is indispensable for diesel engines to meet the increasingly stringent emission regulations. Both the peak temperature and the maximum temperature gradient of the DPF during active regeneration should be well controlled in order to enhance the reliability and durability of the filter. In this paper, the temperature field of the DPF during active regeneration with hydrocarbon (HC) injection was investigated with engine bench tests and numerical simulation. For the experimental study, 24 thermocouples were inserted into the DPF channels to measure the inner temperature of the filter to capture its temperature field, and the circumferential, axial and radial distribution of the filter temperature was analyzed to understand the DPF temperature field behavior during active regeneration.
Technical Paper

Numerical Analysis on the Potential of Reducing DPF Size Using Low Ash Lubricant Oil

2018-09-10
2018-01-1760
Diesel particulate filter (DPF) is necessary for diesel engines to meet the increasingly stringent emission regulations. Many studies have demonstrated that the lubricant derived ash has a significant effect on DPF pressure drop and engine fuel economy, and this effect becomes more and more severe with the increasing of operating hours of the DPF because the ash accumulated in the DPF cannot be removed by regeneration. It is reported that most of the DPFs operated with more ash than soot in the filter for more than three quarters of the time during its lifetime [1]. In order to mitigate this problem, the original engine manufacturers (OEM) tend to use an oversized DPF for the engine. However, it will increase the costs of the DPF and reduce the compactness of the engine aftertreatment system.
Technical Paper

Urea Decomposition at Low Temperature in SCR Systems for Diesel Engines

2014-10-13
2014-01-2808
Selective catalytic reduction (SCR) has been demonstrated as one of the most promising technologies to reduce NOx emissions from heavy-duty diesel engines. To meet the Euro VI regulations, the SCR system should achieve high NOx reduction efficiency even at low temperature. In the SCR system, NH3 is usually supplied by the injection of urea water solution (UWS), therefore it is important to improve the evaporation and decomposition efficiency of UWS at low temperature and minimize urea deposits. In this study, the UWS spray, urea decomposition, and the UWS impingement on pipe wall at low temperature were investigated based on an engine test bench and computational fluid dynamics (CFD) code. The decomposition of urea and deposits was analyzed using thermal gravimetric analysis (TGA), differential scanning calorimetry (DSC) and fourier transform infrared spectroscopy (FTIR).
Technical Paper

Investigation on the Spray Characteristics of DMF- Isooctane Blends using PDPA

2014-04-01
2014-01-1408
Little research has been done on spray characteristics of 2,5-dimethylfuran (DMF), since the breakthrough in its production method as an alternative fuel candidate. In this paper, the spray characteristics of pure fuels (DMF, Isooctane) and DMF-Isooctane blends under different ambient pressures (1 bar, 3 bar and 7 bar) and injection pressures (50 bar, 100 bar and 150 bar) were studied using Phase Doppler Particle Analyzer (PDPA) and high speed imaging. Droplet velocity, size distribution, spray angle and penetration of sprays were examined. Based on the results, DMF had larger SMD and penetration length than isooctane. The surface tension of fuel strongly influenced spray characteristics. Increasing the surface tension by 26 % resulted in 12 % increase in SMD. Higher ambient pressure increased the drag force, but SMD was not influenced by the increased drag force. However, the increased ambient pressure reduced the injection velocity and We number resulting in higher SMD.
Technical Paper

The Impact of GDI Injector Deposits on Engine Combustion and Emission

2017-10-08
2017-01-2248
Gasoline direct injection (GDI) engine technology is now widely used due to its high fuel efficiency and low CO2 emissions. However, particulate emissions pose one challenge to GDI technology, particularly in the presence of fuel injector deposits. In this paper, a 4-cylinder turbocharged GDI engine in the Chinese market was selected and operated at 2000rpm and 3bar BMEP condition for 55 hours to accumulate injector deposits. The engine spark timing, cylinder pressure, combustion duration, brake specific fuel consumption (BSFC), gaseous pollutants which include total hydro carbon (THC), NOx (NO and NO2) and carbon dioxide (CO), and particulate emissions were measured before and after the injector fouling test at eight different operating conditions. Test results indicated that mild injector fouling can result in an effect on engine combustion and emissions despite a small change in injector flow rate and pulse width.
X