Refine Your Search

Topic

Author

Affiliation

Search Results

Standard

Wheel Mounting Elements for Industrial and Agricultural Disc Wheels

1986-06-01
HISTORICAL
J714_198606
This SAE Recommended Practice includes wheel mounting elements subject to standardization in a series of industrial and agricultural disc wheels. The disc may be reversible or nonreversible and concave or convex (See Figure 1 and Table 1).
Standard

Discharge Signal Lighting System

2008-09-02
HISTORICAL
J2320_200809
This SAE Recommended Practice applies to motor vehicle signaling and marking devices which use light generated by a discharge source. This document provides test methods, requirements, and guidelines applicable to the unique characteristics of discharge lighting systems and their components. These are in addition to those required for signal and marking devices. This document is intended to be a guide to standard practice and is subject to change to reflect additional experience and technical advances.
Standard

Engine and Transmission Dipstick Marking

1977-08-01
HISTORICAL
J614_197708
This SAE Recommended Practice provides information useful in the marking of engine and transmission dipsticks used for fluid level indication.
Video

SAE Eye on Engineering: Ford's new steel-bodied Ranger

2018-11-08
Today, ford motor company begins U.S. production of its 2019 Ranger, the company's first midsize pickup. In this episode of SAE Eye on Engineering, Editor-in-Chief Lindsay Brooke looks at the new steel-bodied Ranger. SAE Eye on Engineering also airs Monday mornings on WJR 760 AM Detroit's Paul W. Smith Show.
Standard

Standard Rainflow File Format

2018-08-24
CURRENT
J2623_201808
This SAE Standard provides a definition of a rainflow file format. This type of simple text file would contain all relevant information about the rainflow cycle content of a time history. Included information are Comments, Signal Range, Signal Mean, Number of Cycles, Signal Maximum, Signal Minimum. Rainflow cycle counting has become the most accepted procedure for identifying material fatigue relevant cycles in complex variable amplitude load time histories. The cycle counting methods account for the effects of material plasticity and material memory of prior deformation, and the resulting compressed history information is used by durability analysts to estimate the effects of a given service or test history.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2013-04-09
HISTORICAL
J2691_201304
This SAE standard establishes the minimum construction and performance requirements for a 15 Pole Connector Between Towing Vehicles and Trailers, for trucks, trailers, and dollies in conjunction with SAE J2742 “Combination 11 Conductors and 4 Pairs ECBS Cable”. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2018-04-15
CURRENT
J2691_201804
This SAE standard establishes the minimum construction and performance requirements for a 15 Pole Connector Between Towing Vehicles and Trailers, for trucks, trailers, and dollies in conjunction with SAE J2742. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Video

SAE Eye on Engineering: Conti's Virtual A-Pillar tech

2018-11-13
The pillars that frame both sides of your car's windshield are known as the A pillars. In this episode of SAE Eye on Engineering, Editor-in-Chief Lindsay Brooke looks at Continental's new "Virtual" A pillar. SAE Eye on Engineering also airs Monday mornings on WJR 760 AM Detroit's Paul W. Smith Show.
Standard

ROAD VEHICLES – 60 V AND 600 V SINGLE CORE (ISO/METRIC) CABLES – DIMENSIONS, TEST METHODS AND REQUIREMENTS

2002-09-09
HISTORICAL
USCAR23
This International Standard specifies the dimensions, test methods, and requirements for single core 60 V cables intended for use in road vehicle applications where the nominal system voltage is ≤ (60 V DC or 25 V AC). It also specifies additional test methods and/or requirements for 600 V cables intended for use in road vehicle applications where the nominal system voltage is > (60 V DC or 25 V AC) to ≤ (600 V DC or 600 V AC). It also applies to individual cores in multi-core cables. See ISO 6722 for “Temperature Class Ratings”.
Standard

Reflex Reflectors for Use on Vehicles 2032 mm or More in Overall Width

2018-05-02
WIP
J2041
This SAE Standard provides test procedures, requirements, and guidelines for reflex reflectors used on vehicles 2032 mm or more in overall width. Reflex reflectors conforming to these requirements may also be used on vehicles less than 2032 mm in overall width.
Standard

Reflex Reflectors for Use on Vehicles 2032 mm or More in Overall Width

2013-10-21
CURRENT
J2041_201310
This SAE Standard provides test procedures, requirements, and guidelines for reflex reflectors used on vehicles 2032 mm or more in overall width. Reflex reflectors conforming to these requirements may also be used on vehicles less than 2032 mm in overall width.
X