Refine Your Search

Topic

Author

Affiliation

Search Results

Standard

Vehicle Electromagnetic Immunity--On-Board Transmitter Simulation

2009-08-03
CURRENT
J551/12_200908
This part of SAE J551 specifies on-board transmitter simulation test methods and procedures for testing passenger cars and commercial vehicles. The electromagnetic disturbances considered in this part of SAE J551 are limited to continuous narrow band electromagnetic fields. SAE J551/1 specifies general, definitions, practical use, and basic principles of the test procedure.
Standard

R134a Refrigerant Charge Determination Test Method

2018-09-11
CURRENT
J3023_201809
The purpose of this document is to establish guidelines for determining the critical R134a refrigerant charge for off-road, self-propelled work machines as defined in SAE J1116 and Agricultural Tractors as defined in ANSI/ASAE S390. It will develop a minimum to maximum refrigerant charge range in which the HVAC system can maintain proper operation. Operating conditions and characteristics of the equipment will influence the optimum charge. Since these conditions and characteristics vary greatly from one application to another, careful consideration should be taken to determine the optimum R134a refrigerant charge for the HVAC system.
Standard

Electromagnetic Testing by Eddy Current Methods

2018-01-09
CURRENT
J425_201801
The purpose of this SAE Information Report is to provide general information relative to the nature and use of eddy current techniques for nondestructive testing. The document is not intended to provide detailed technical information but to serve as an introduction to the principles and capabilities of eddy current testing, and as a guide to more extensive references listed in Section 2.
Standard

ELECTROMAGNETIC TESTING BY EDDY CURRENT METHODS

1991-03-01
HISTORICAL
J425_199103
The purpose of this SAE Information Report is to provide general information relative to the nature and use of eddy current techniques for nondestructive testing. The document is not intended to provide detailed technical information but to serve as an introduction to the principles and capabilities of eddy current testing, and as a guide to more extensive references listed in Section 2.
Standard

Electromagnetic Testing By Eddy Current Methods

1981-03-01
HISTORICAL
J425_198103
The purpose of this SAE Information Report is to provide general information relative to the nature and use of eddy current techniques for nondestructive testing. The document is not intended to provide detailed technical information but to serve as an introduction to the principles and capabilities of eddy current testing, and as a guide to more extensive references listed in Section 2.
Standard

Electromagnetic Testing By Eddy Current Methods

1976-04-01
HISTORICAL
J425B_197604
The purpose of this SAE Information Report is to provide general information relative to the nature and use of eddy current techniques for nondestructive testing. The document is not intended to provide detailed technical information but to serve as an introduction to the principles and capabilities of eddy current testing, and as a guide to more extensive references listed in Section 2.
White Paper

REDUCING DOWNTIME THROUGH THE USE OF PREDICTIVE ANALYTICS AND TECHNICAL TRAINING ADVANCEMENTS

2018-01-05
WP-0007
The exponential increase in the number of aircraft and air travelers has triggered new innovations aimed to make airline services more reliable and consumer friendly. Quick and efficient maintenance actions with minimum downtime are the need of the hour. Another major challenge is ensuring maintenance personnel are trained effectively; technology like augmented reality and Virtual Maintenance Trainers (VMTs) may provide safe and efficient training in lieu of live, instructor-led arrangements. And while traditional User/Maintenance Manuals provide useful information when dealing with simple machines, when dealing with complex systems of systems and miniaturized technologies, like unmanned aerial vehicles (UAVs), new technologies like augmented reality can rapidly and effectively support the maintenance operations.
Standard

ROAD VEHICLES – 60 V AND 600 V SINGLE CORE (ISO/METRIC) CABLES – DIMENSIONS, TEST METHODS AND REQUIREMENTS

2002-09-09
HISTORICAL
USCAR23
This International Standard specifies the dimensions, test methods, and requirements for single core 60 V cables intended for use in road vehicle applications where the nominal system voltage is ≤ (60 V DC or 25 V AC). It also specifies additional test methods and/or requirements for 600 V cables intended for use in road vehicle applications where the nominal system voltage is > (60 V DC or 25 V AC) to ≤ (600 V DC or 600 V AC). It also applies to individual cores in multi-core cables. See ISO 6722 for “Temperature Class Ratings”.
Standard

Reflex Reflectors for Use on Vehicles 2032 mm or More in Overall Width

2018-05-02
WIP
J2041
This SAE Standard provides test procedures, requirements, and guidelines for reflex reflectors used on vehicles 2032 mm or more in overall width. Reflex reflectors conforming to these requirements may also be used on vehicles less than 2032 mm in overall width.
Standard

Reflex Reflectors for Use on Vehicles 2032 mm or More in Overall Width

2013-10-21
CURRENT
J2041_201310
This SAE Standard provides test procedures, requirements, and guidelines for reflex reflectors used on vehicles 2032 mm or more in overall width. Reflex reflectors conforming to these requirements may also be used on vehicles less than 2032 mm in overall width.
Standard

Ethics for Accident Investigation and Reconstruction

2011-02-18
CURRENT
J2314_201102
The purpose of this SAE Recommended Practice is to promote the highest professional and personal conduct of practitioners in the fields of accident investigation and reconstruction. It encourages the continuous application of high ethical principles to one’s own endeavors. It also encourages the application of these same principles to others associated with accident investigation and reconstruction.
Standard

Top Speed Test Procedure for Electric Motorcycles

2014-02-21
CURRENT
J3007_201402
This SAE Recommended Practice incorporates a track-based test procedure that produces a representative value for vehicle top speed when operating on a level paved road with a fully charged battery.
Standard

Refrigerant 12 Automotive Air-Conditioning Hose

2015-04-21
CURRENT
J51_201504
This SAE Standard covers reinforced hose, or hose assemblies, intended for conducting liquid and gaseous dichlorodifluoromethane (refrigerant 12) in automotive air-conditioning systems. The hose shall be designed to minimize permeation of refrigerant 12 and contamination of the system and to be serviceable over a temperature range of −30 to 120 °C (−22 to 248 °F). Specific construction details are to be agreed upon between user and supplier.1 NOTE—R12 refrigerant has been placed on a banned substance list due to its ozone depletion characteristics. SAE J51 specification will be phased out as new automotive A/C systems are using R134a. SAE J2064 is the Standard for refrigerant 134a hose. For refrigerant 134a use, refer to SAE J2064.