Refine Your Search

Search Results

Standard

Plain Bearing High Speed Oscillation Test

2007-07-09
CURRENT
ARP5448/2
This test method outlines a standard procedure for performing cyclic reversing load testing on oscillating sliding bearings. The wear data from these tests is to be used for qualification requirements and to establish bearing design criteria.
Standard

Plain Bearing Low Speed Oscillation Test

2002-07-31
HISTORICAL
ARP5448/3
This test method outlines a standard procedure for performing unidirectional load dynamic testing of self-lubricating bearings at room temperature, elevated temperature or sub-zero temperature, dry or contaminated with fluids. The wear data from these tests is to be used for qualification and to establish bearing design criteria.
Standard

Plain Bearing Bond Integrity - Peelable Woven Fabric PTFE Liners

2002-06-06
CURRENT
ARP5448/4
This test method outlines a recommended procedure for performing bond integrity tests of bonded peelable woven fabric reinforced polytetrafluoroethylene (PTFE) liners, hereafter referred to within this document as "PTFE liner" or "liner". The data from these tests shall be used to determine if the product meets the "bond integrity" requirements of the applicable specifications.
Standard

Plain Bearing Low Speed Oscillation Test

2016-07-19
CURRENT
ARP5448/3A
This test method outlines a recommended procedure for performing unidirectional load dynamic testing of self-lubricating bearings at room temperature, elevated temperature or sub-zero temperature, dry or contaminated with fluids. The wear data from these tests is to be used for qualification and to establish bearing design criteria.