Refine Your Search

Topic

Author

Affiliation

Search Results

Standard

R134a Refrigerant Charge Determination Test Method

2018-09-11
CURRENT
J3023_201809
The purpose of this document is to establish guidelines for determining the critical R134a refrigerant charge for off-road, self-propelled work machines as defined in SAE J1116 and Agricultural Tractors as defined in ANSI/ASAE S390. It will develop a minimum to maximum refrigerant charge range in which the HVAC system can maintain proper operation. Operating conditions and characteristics of the equipment will influence the optimum charge. Since these conditions and characteristics vary greatly from one application to another, careful consideration should be taken to determine the optimum R134a refrigerant charge for the HVAC system.
Book

Electronic Transmission Controls

2000-06-10
The evolution of the automotive transmission has changed rapidly in the last decade, partly due to the advantages of highly sophisticated electronic controls. This evolution has resulted in modern automatic transmissions that offer more control, stability, and convenience to the driver. Electronic Transmission Controls contains 68 technical papers from SAE and other international organizations written since 1995 on this rapidly growing area of automotive electronics. This book breaks down the topic into two sections. The section on Stepped Transmissions covers recent developments in regular and 4-wheel drive transmissions from major auto manufacturers including DaimlerChrysler, General Motors, Toyota, Honda, and Ford. Technology covered in this section includes: smooth shift control; automatic transmission efficiency; mechatronic systems; fuel saving technologies; shift control using information from vehicle navigation systems; and fuzzy logic control.
Standard

ROAD VEHICLES – 60 V AND 600 V SINGLE CORE (ISO/METRIC) CABLES – DIMENSIONS, TEST METHODS AND REQUIREMENTS

2002-09-09
HISTORICAL
USCAR23
This International Standard specifies the dimensions, test methods, and requirements for single core 60 V cables intended for use in road vehicle applications where the nominal system voltage is ≤ (60 V DC or 25 V AC). It also specifies additional test methods and/or requirements for 600 V cables intended for use in road vehicle applications where the nominal system voltage is > (60 V DC or 25 V AC) to ≤ (600 V DC or 600 V AC). It also applies to individual cores in multi-core cables. See ISO 6722 for “Temperature Class Ratings”.
Standard

Diesel Injection Pump Testing—Part 2: Orifice Plate Flow Measurement

2015-09-22
CURRENT
J968/2_201509
This part of SAE J968 specifies the flow measuring system, including the fixture, to be used for flow testing the single hole orifice plates used in an orifice plate type nozzle and holder assembly (described in SAE J968-1) which is intended for testing and setting diesel fuel injection pumps on test benches. The flow measuring system and fixture ensure accurate flow testing of the entire range of orifices from 0.4 to 0.8 mm diameter as specified in SAE J968-1. It is intended primarily for use by the manufacturers of single hole orifice plates.
Standard

Diesel Injection Pump Testing—Part 2: Orifice Plate Flow Measurement

2002-12-20
HISTORICAL
J968/2_200212
This part of SAE J968 specifies the flow measuring system, including the fixture, to be used for flow testing the single hole orifice plates used in an orifice plate type nozzle and holder assembly (described in SAE J968-1) which is intended for testing and setting diesel fuel injection pumps on test benches. The flow measuring system and fixture ensure accurate flow testing of the entire range of orifices from 0.4 to 0.8 mm diameter as specified in SAE J968-1. It is intended primarily for use by the manufacturers of single hole orifice plates.
Book

Fuel Cell Systems Explained, Second Edition

2003-05-01
Fuel cell technology is developing at a rapid pace, thanks to the increasing awareness of the need for pollution-free power sources. Moreover, new developments in catalysts and improved reliability have made fuel cells viable candidates in a road range of applications, from small power stations, to cars, to laptop computers and mobile phones. Building on the success of the first edition, Fuel Cell Systems Explained presents a balanced introduction to this growing area. "In summary, an altogether satisfying book that puts within its covers the academic tools necessary for explaining fuel cell systems on a multidisciplinary basis." - Power Engineering Journal "An excellent book...well written and produced."- Journal of Power and Energy
Book

Nonlinear and Hybrid Systems in Automotive Control

2003-05-01
A new generation of strategies for vehicle and engine control systems has become necessary because of increasing requirements for accuracy, ride, comfort, safety, complexity, and emission levels. In contrast with earlier systems, new control systems are based on dynamic physical models and the principles of advanced nonlinear control. With contributions from leading scientists in the field, this book presents an overview of research in this rapidly-expanding area. New approaches to solving theoretical problems, as well as numerous systems and control research issues, are covered.
Standard

Low-Permeation Fuel Fill and Vent Tube

2007-07-02
CURRENT
J2405_200707
This SAE Standard covers the minimum requirements for a low-permeation tubing (100 g/m2·day or less) for use as a low pressure (14.5 kPa) liquid- or vapor-carrying component for use in gasoline or diesel fuel filler, vent, and vapor systems. The construction shall be designed to be functional over a temperature range of –40 °C to 100 °C for the T1 designation, or –40 °C to 125 °C for the T2 designation.
X