Standard

Aerospace - Passive Side Stick Unit General Requirements for Fly by Wire Transport and Business

2012-07-31
HISTORICAL
ARP6001
This SAE Aerospace Recommended Practice (ARP) provides general requirements for a generic “passive” side stick that could be used for fly by wire transport and business aircraft. It addresses the following: The functions to be implemented The geometric and mechanical characteristics The mechanical and electrical interfaces The safety and certification requirements
Standard

Aerospace - Passive Side Stick Unit General Requirements for Fly by Wire Transport and Business

2018-10-04
HISTORICAL
ARP6001A
This SAE Aerospace Recommended Practice (ARP) provides general requirements for a generic “passive” side stick that could be used for fly by wire transport and business aircraft. It addresses the following: The functions to be implemented The geometric and mechanical characteristics The mechanical and electrical interfaces The safety and certification requirements
Standard

Aerospace - Passive Side Stick Unit General Requirements for Fly-by Wire Transport and Business

2020-04-23
CURRENT
ARP6001B
This SAE Aerospace Recommended Practice (ARP) provides recommendations for design and test requirements for a generic “passive” side stick that could be used for fly-by wire transport and business aircraft. It addresses the following: The functions to be implemented The geometric and mechanical characteristics The mechanical and electrical interfaces The safety and certification requirements
Standard

AIR TRANSPORT AVIONICS EQUIPMENT INTERFACES

2017-07-11
CURRENT
ARINC600-20
ARINC 600 is a mechanical packaging standard that is used with the ARINC 700-series of digital avionics equipment. It provides mechanical, electrical, and environmental interfaces between LRUs and the racks or cabinets in which they are installed. Provides connector shell definition, connector insert layout and mounting dimensions.
Standard

Wire, Electrical, Fluoropolymer-Insulated, Copper or Copper Alloy

2023-02-15
WIP
AS22759E
AS22759 specification covers fluoropolymer-insulated single conductor electrical wires made with tin-coated, silver-coated, or nickel-coated conductors of copper or copper alloy as specified in the applicable detail specification. The fluoropolymer insulation may be polytetrafluoroethylene (PTFE), fluorinated ethylene propylene (FEP), polyvinylidene fluoride (PVF2), ethylene-tetrafluoroethylene copolymer (ETFE), or other Fluoropolymer resin. The fluoropolymer may be used alone or in combination with other insulation materials. These abbreviations shall be used herein. When a wire is referenced herein, it means an insulated conductor (see 7.7).