Refine Your Search

Search Results

Technical Paper

Evaluation of a Proposed Hybrid III Hip Modification

1995-11-01
952730
A proposed modification to the Hybrid III 50th percentile male dummy upper femur appears to reduce the chest response problems resulting from femur-pelvis interaction in test exposures more severe than Standard No. 208 testing. When compared to overall repeatability of tests, the modification did not change other dummy response measurements appreciably. The femur-pelvis interaction problem, referred to as “hip lock”, was thought to occur in certain vehicles when the femurs of a passenger side dummy impacting only an air bag bottomed out against the pelvis structure. If metal-to-metal contact occurred, excessive load could be transferred to the chest, leading to elevated chest responses. The most pertinent signs of hip lock occurring appear to be a large, sharply pointed z chest acceleration, and a distinct positive component of the lumbar spine z force following the main negative component.