Oxygen Considerations for High Elevation Airport Operations (HEAO)

2021-08-26
CURRENT
AIR6829
This document covers information concerning the use of oxygen when flying into and out of high elevation airports for both pressurized and non-pressurized aircraft. Oxygen requirements for pressurized aircraft operating at high altitudes have for decades emphasized the potential failures that could lead to a loss of cabin pressurization coupled with the potential severe hypoxic hazard that decompressions represent. This document is intended to address the case where the relationship between cabin and ambient pressures are complicated by operations at high terrestrial altitudes. Operators who fly into these high-altitude airports should address the issues related to this environment because it carries the potential for insidious hypoxia and other conditions which can affect safety. It provides information to consider in developing operational procedures to address hypoxia concerns consistent with regulatory mandates.
Standard

Oxygen Sensor Technologies

2020-12-18
CURRENT
AIR5933
AIR5933 provides an overview of contemporary technologies (i.e., sensors) that measure the proportion of oxygen in a gas. The use of these sensors in the aerospace environment, with its special constraints, is discussed and papers/reports with detailed information are summarized and referenced. The sensors are divided into expendable and non-expendable sensors. Expendable sensors are based on electrochemical properties, whereas non-expendable sensors rely on paramagnetic, photo-acoustic, electromagnetic, and laser spectroscopy properties.
Standard

Portable Chemical Oxygen

2011-06-21
HISTORICAL
AS1303A
This SAE Aerospace Standard (AS) applies to a portable chemical oxygen generator assembly intended for the following uses: a First aid treatment of aircraft occupants after an emergency descent following a decompression or other emergency condition. b Use by cabin attendants to maintain their mobility after a decompression.
Standard

Portable Chemical Oxygen

2017-01-04
CURRENT
AS1303B
This SAE Aerospace Standard (AS) applies to a portable chemical oxygen generator assembly intended for the following uses: a First aid treatment of aircraft occupants after an emergency descent following a decompression or other emergency condition. b Use by cabin attendants to maintain their mobility after a decompression.
Standard

Chemical Oxygen Systems

2021-08-09
CURRENT
AIR825/4A
This SAE Aerospace Information Report (AIR) provides an orientation regarding the general technology of chemical oxygen generators to aircraft engineers for assistance in determining whether chemical oxygen generators are an appropriate oxygen supply source for hypoxia protection in a given application and as an aid in specifying such generators. Information regarding the details of design and manufacture of chemical oxygen generators is generally beyond the scope of this document.
Standard

Aerospace Information Report for Continuous Flow Oxygen Hose Disconnect Fittings

2009-08-27
HISTORICAL
AIR1358B
This Aerospace Information Report (AIR) indicates those dimensions, deemed critical by the manufacturer to assure proper mating of disconnect hose fittings. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

Aerospace Information Report for Continuous Flow Oxygen Hose Disconnect Fittings

2000-10-01
HISTORICAL
AIR1358A
This AIR indicates those dimensions, deemed critical by the manufacturer, which are required to be adhered to so that proper mating of the disconnect hose fitting with the correct disconnect be accomplished. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

AEROSPACE INFORMATION REPORT FOR CONTINUOUS FLOW OXYGEN HOSE DISCONNECT FITTINGS

1991-09-01
HISTORICAL
AIR1358
This AIR indicates those dimensions, deemed critical by the manufacturer, which are required to be adhered to so that proper mating of the disconnect hose fitting with the correct disconnect be accomplished. The dimensions are critical, but not necessarily complete, in defining these fittings since there are other criteria which must also be met.
Standard

Useful Life Determination for Chemical Oxygen Generators

2013-12-13
HISTORICAL
ARP1894A
The scope of this document is to provide a guideline for the preparation of a plan for testing of inservice chemical oxygen generators to confirm their design useful life. The test program should also allow determination with a sufficient level of confidence, whether generators are suitable for further use (i.e., life extension, or if the useful life limit has been reached).
Standard

USEFUL LIFE DETERMINATION CHEMICAL OXYGEN GENERATORS

1987-02-01
HISTORICAL
ARP1894
This document provides recommended guidelines for a comprehensive program to determine the useful life of chemical oxygen generators where useful life is defined as the sum of shelf and service life. Further, this document provides for a test program to determine with a sufficient level of confidence if the generators are suitable for further use and/or if the life limit has been reached. This program should include testing of generators of a representative sampling of a given year's production, of a particular part number, to provide a level of confidence sufficient to permit the units to be used for an additional specified time period.
Standard

Useful Life Determination for Chemical Oxygen Generators

2014-02-13
CURRENT
ARP1894B
The scope of this document is to provide a guideline for the preparation of a plan for testing of inservice chemical oxygen generators to confirm their design useful life. The test program should also allow determination with a sufficient level of confidence, whether generators are suitable for further use (i.e., life extension, or if the useful life limit has been reached).
Standard

STANDARD FOR OXYGEN FLOW INDICATORS

1966-07-01
HISTORICAL
AS916
This standard is intended to establish general material and design requirements for oxygen flow indicating devices. Flow indicators considered are for diluter-demand and continuous flow systems.
Standard

Oxygen Flow Indication

2019-01-10
CURRENT
AS916C
This SAE Aerospace Standard (AS) defines the overall requirements applicable to oxygen flow indication as required by Airworthiness Requirements of CS/FAR 25.1449 to show that oxygen is being delivered to the dispensing equipment. Requirements of this document shall be applicable to any type of oxygen system technology and encompass “traditional” pneumatic devices, as well electric/electronic indication.
Standard

Carry-On Portable Oxygen Concentrators

2017-11-07
CURRENT
AS8059
This SAE Aerospace Standard (AS) applies to a personal, portable oxygen concentrator (POC) to be supplied and used by a passenger requiring supplemental oxygen therapy while traveling on board civil, commercial, or personal aircraft. It covers a POC during both self-powered battery operation and while powered from an aircraft seat’s electrical power through the use of an accessory adapter. The POC is not intended to be connected to the aircraft’s oxygen systems or to be used by any aircraft personnel in any method of treatment or first aid of the general flying public.
Standard

Continuous Flow Oxygen Systems

2023-01-26
CURRENT
AIR825/8
This SAE Aerospace Information Report (AIR) provides general information on Continuous Flow Oxygen Systems which are available, principle functions of those systems and technical approaches to be taken into account during design and realization of systems. However, particular performance specifications and detailed information of manufacturing, testing and integration of such systems is beyond the scope of this document.
Standard

Testing of Oxygen Equipment

2021-08-11
CURRENT
ARP1398A
This ARP delineates requirements for system cleanliness, test gas supply system, test stand design, environmental chamber definition, instrumentation, dynamic test equipment and testing procedures.