Refine Your Search

Search Results

Viewing 1 to 14 of 14
Standard

SECONDARY FILTERS FOR FLUID SYSTEM RELIABILITY

1994-05-01
HISTORICAL
AIR4057
It discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

Secondary Filters for Fluid System Reliability

2012-09-24
CURRENT
AIR4057B
This SAE Aerospace Information Report (AIR) discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

Secondary Filters for Fluid System Reliability

2000-12-01
HISTORICAL
AIR4057A
This SAE Aerospace Information Report (AIR) discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

METHODS FOR EVALUATING CRYOGENIC FILTERS

1975-07-01
HISTORICAL
ARP900
The purpose of this test procedure is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters up to and including 60 GPM (330 liters per minute) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system.
Standard

Methods for Evaluating Cryogenic Filters

2019-12-03
CURRENT
ARP900C
The purpose of this document is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures.
Standard

Methods for Evaluating Cryogenic Filters

1992-06-29
HISTORICAL
ARP900A
The purpose of this test procedure is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters up to and including 60 gpm (230 lpm) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system.
Standard

Methods for Evaluating Cryogenic Filters

2011-12-19
HISTORICAL
ARP900B
The purpose of this document is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters for particle sizes equal to or greater than 5.0 μm and flows up to and including 60 gpm (230 L/min) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system from those recommended in this document.
Standard

Filter Patch Testing Procedures for Aerospace Hydraulic Pumps and Motors

1999-07-01
CURRENT
ARP575B
This Aerospace Recommended Practice (ARP) sets forth recommendations of SAE Subcommittee A-6C (Fluid Power Distribution Elements) relative to the procedure and methods to be used in the obtaining and evaluation of filter patch tests for aerospace hydraulic pumps and motors. These patches are to be used in a quality control program to insure that units are operating properly prior to delivery to the customer. This is to promote an optimum in cleanliness standards in aerospace hydraulic circuits. It is expected that this will promote a longer service life of the pump or motor.
Standard

Liquid Filter Ratings, Parameters and Tests

1968-05-31
HISTORICAL
AIR887
This SAE Aerospace Information Report (AIR) identifies and explains the meaning of various ratings and terms used to describe the physical characteristics of liquid filter elements. The significance of various filter parameters is discussed. In addition, a number of filter test methods is briefly described. This AIR and the data presented are only applicable to filters in which the system liquid wets the filter elements. This document includes equivalent metric units (in parentheses) as referenced information.
X