Refine Your Search

Topic

Search Results

Standard

CUSHION TOW HITCHES TEST

1992-08-18
HISTORICAL
AIR1353A
The main purpose of this test was to determine the application advantages of cushion tow hitches in comparison to the commonly used rigid tow hitch type fitted on heavy aircraft towing tractors. As diverse opinions emerged about its suitability since the introduction on the market of this new tow hitch type, it was intended to physically measure and evaluate the damping capability of this cushioned tow link when applied in practice.
Standard

Cushion Tow Hitches Test

2006-02-09
HISTORICAL
AIR1353B
The main purpose of this test was to determine the application advantages of cushion tow hitches in comparison to the commonly used rigid tow hitch type fitted on heavy aircraft towing tractors. As diverse opinions emerged about its suitability since the introduction on the market of this new tow hitch type, it was intended to physically measure and evaluate the damping capability of this cushioned tow link when applied in practice.
Standard

SOLID-STATE FREQUENCY CONVERTER 400 HERTZ, 3-PHASE OUTPUT

1989-09-01
HISTORICAL
ARP1940
This specification covers the requirements for solid-state frequency converters with 480 [or 380] V 3-phase, 60 [or 50] Hz input and 115/200 V, 3-phase, 400 Hz output capable of powering aircraft type loads requiring MIL-STD-704D quality power. The frequency converter shall be a self-contained unit suitable for the environment of intended use. Typical applications include dedicated use at passenger loading bridges (mounted under the bridge in telescoping bridge applications or fixed installation at base of stationary type loading bridges) with weatherproof enclosures or hangar/lab use where indoor fixed or portable units can be used.
Standard

Aural Protector, Sound

1999-05-01
HISTORICAL
AS23899
This specification covers the design and performance requirements for one type of sound aural protector.
Standard

Aural Protector, Sound

2012-01-24
CURRENT
AS23899A
This specification covers the design and performance requirements for one type of sound aural protector.
Standard

Method of Testing Pre-Conditioned Air Equipment

2008-04-15
HISTORICAL
ARP5374A
This SAE Aerospace Recommended Practice (ARP) applies to Point-Of-Use, Central and Mobile Pre-Conditioned Air Equipment. It does not apply to aircraft mounted equipment.
Standard

Aircraft Markings for Ground Support Equipment Alignment

2020-04-24
CURRENT
AS6896
The purpose of this document is to provide a standard for aircraft fuselage markings located at the doors used for ground servicing operations. These markings can be used by all GSE that will dock at the aircraft. These markings may be used for one or several phases of the GSE positioning relative to the aircraft process: GSE alignment during approach, GSE final docking, and GSE auto leveling. It is not the purpose of this standard to describe the different technologies, cameras, or other equipment that can be mounted on GSE to utilize these markings. The aircraft that may use these markings will have a fuselage diameter of 3 m or more.
Standard

Aircraft Damage Caused by Ground Support Equipment

2009-12-09
HISTORICAL
AIR1589A
Only those incidents where a piece of ground support equipment directly associated with the "turnaround" servicing of an aircraft was involved are reviewed. Specifically excluded are those incidents that occurred during heavy maintenance, overhaul activity, or aircraft taxiing.
Standard

Aircraft Damage Caused by Ground Support Equipment

2016-06-06
HISTORICAL
AIR1589B
Only those incidents where a piece of ground support equipment directly associated with the "turnaround" servicing of an aircraft was involved are reviewed. Specifically excluded are those incidents that occurred during heavy maintenance, overhaul activity, or aircraft taxiing.
Standard

Aircraft Damage Caused by Ground Support Equipment

2022-05-16
CURRENT
AIR1589C
Incidents where a piece of ground support equipment or personnel damages an aircraft under the control of ground or maintenance operations that requires corrective action by aircraft maintenance personnel. Operations include, but are not limited to servicing, line maintenance, heavy maintenance, and aircraft movement, e.g., marshalling/pushback/tow/reposition/taxi.
Standard

400 Hz Connection Aircraft Electrical Maintenance Procedures

2008-03-28
HISTORICAL
AIR4365A
This SAE Aerospace Information Report (AIR) describes field-level procedures to determine if 400 Hz electrical connections for external power may have been subjected to excessive wear, which may result in inadequate disengagement forces.
Standard

400 Hz CONNECTION AIRCRAFT ELECTRICAL MAINTENANCE PROCEDURES

1994-12-01
HISTORICAL
AIR4365
This SAE Aerospace Information Report (AIR) describes field-level procedures to determine if 400 Hz electrical connections for external power may have been subjected to excessive wear, which may result in inadequate disengagement forces.
Standard

Ground Support Equipment Hydraulic Systems, Design and Installation, Recommended Practices for

2022-12-16
CURRENT
ARP4943A
This SAE Aerospace Recommended Practice (ARP) covers the design and installation requirements for hydraulic systems (up to 8000 psig [56 MPa]) for ground support equipment (GSE). This ARP is derived from AS5440, which provides hydraulic system requirements for aircraft. The recommendations herein are primarily intended for GSE that exchange hydraulic fluid with the aircraft, such as hydraulic service carts, rather than GSE with non-interfacing hydraulic systems. The GSE may be mobile, portable, or stationary.
Standard

Pictograms for Ground Support Equipment

1999-12-01
HISTORICAL
ARP1838A
This SAE Aerospace Recommended Practice (ARP) specifies pictographic symbols for ground support equipment. They have been compiled for the benefit of those who deal with such equipment like airlines, airport authorities, manufacturers etc. in order to facilitate fast and accurate identification of controls, indicators, and decals of powered and unpowered equipment. This document shall promote standardization of terms for controls, indicators etc. of ground support equipment and eliminate language problems. It is recommended to put these pictograms on all future equipment and to retrofit all existing equipment as far as possible.
Standard

AIRCRAFT ENVIRONMENTAL FACTORS FOR DESIGN CONSIDERATION

2002-12-16
CURRENT
AIR1309
This AIR is presented in two parts - the first part, to alert the engineer with respect to the environmental factors which he might have to consider - the second part, as tabular data and figures to which he can refer with respect to a specific geographical location.
X