Technical Paper

Water Quality Program Elements for Space Station Freedom

1991-07-01
911400
Space Station Freedom (SSF) will be operational for up to 30 years with missions lasting up to 180 days. Because of the need for large amounts of potable and hygiene water for the crews, it will not be practical to supply water from the ground (as was done for Skylab) or to generate water from fuel cells (as is done for the Shuttle). Hence, waste and metabolic waters will be reclaimed and recycled in SSF. Because of the unique nature of the water sources and the closed loop recycling processes, providing safe water will be a challenging task. Developing a program for the verification of SSF water quality to ensure crew health is the responsibility of NASA's Medical Sciences Division at the Johnson Space Center (JSC). This program is being implemented through the Environmental Health System (EHS). This paper will describe the strategy for the development of water quality criteria and standards, and the associated monitoring requirements.
Technical Paper

Sampling and Chemical Analysis of Potable Water for ISS Expeditions 12 and 13

2007-07-09
2007-01-3214
The crews of Expeditions 12 and 13 aboard the International Space Station (ISS) continued to rely on potable water from two different sources, regenerated humidity condensate and Russian ground-supplied water. The Space Shuttle launched twice during the 12-months spanning both expeditions and docked with the ISS for delivery of hardware and supplies. However, no Shuttle potable water was transferred to the station during either of these missions. The chemical quality of the ISS onboard potable water supplies was verified by performing ground analyses of archival water samples at the Johnson Space Center (JSC) Water and Food Analytical Laboratory (WAFAL). Since no Shuttle flights launched during Expedition 12 and there was restricted return volume on the Russian Soyuz vehicle, only one chemical archive potable water sample was collected with U.S. hardware and returned during Expedition 12. This sample was collected in March 2006 and returned on Soyuz 11.
Technical Paper

Colorimetric-Solid Phase Extraction Technology for Water Quality Monitoring: Evaluation of C-SPE and Debubbling Methods in Microgravity

2007-07-09
2007-01-3217
Colorimetric-solid phase extraction (C-SPE) is being developed as a method for in-flight monitoring of spacecraft water quality. C-SPE is based on measuring the change in the diffuse reflectance spectrum of indicator disks following exposure to a water sample. Previous microgravity testing has shown that air bubbles suspended in water samples can cause uncertainty in the volume of liquid passed through the disks, leading to errors in the determination of water quality parameter concentrations. We report here the results of a recent series of C-9 microgravity experiments designed to evaluate manual manipulation as a means to collect bubble-free water samples of specified volumes from water sample bags containing up to 47% air. The effectiveness of manual manipulation was verified by comparing the results from C-SPE analyses of silver(I) and iodine performed in-flight using samples collected and debubbled in microgravity to those performed on-ground using bubble-free samples.
Technical Paper

Risk Mitigation Water Quality Monitor

1997-07-01
972463
On the International Space Station (ISS), atmospheric humidity condensate and other waste waters will be recycled and treated to produce potable water for use by the crews. Space station requirements include an on-orbit capability for real-time monitoring of key water quality parameters, such as total organic carbon, total inorganic carbon, total carbon, pH, and conductivity, to ensure that crew health is protected for consumption of reclaimed water. The Crew Health Care System for ISS includes a total organic carbon (TOC) analyzer that is currently being designed to meet this requirement. As part of the effort, a spacecraft TOC analyzer was developed to demonstrate the technology in microgravity and mitigate risks associated with its use on station. This analyzer was successfully tested on Shuttle during the STS-81 mission as a risk mitigation experiment. A total of six ground-prepared test samples and two Mir potable water samples were analyzed in flight during the 10-day mission.
Technical Paper

Electrochemically-Driven Micropump for Fluid Flow and Delivery: Toward a Novel Micropump Design for Miniaturized Liquid Chromatographic and Flow Injection Analyses

1997-07-01
972420
This paper describes the development of a prototype fluid pumping system for incorporation into a miniaturized flow injection analyzer. The strategy couples the well-established capabilities of reagent-based flow injection analyses (FIA) with our novel concepts for the design of a miniaturized, low-power pumping system, i.e., an electrochemically-driven micropump. The basis of pump actuation relies on the electrochemically-induced surface tension changes at the electrolyte/mercury interface, resulting in a “piston-like” pumping process devoid of mechanically moving parts. We present herein the results from the preliminary performance tests of a miniaturized fluid flow system with the micropump. As described, the flow rates and pumping displacement volumes have been studied as a function of the amplitude and the frequency of the applied voltage waveform.
Technical Paper

Humidity Condensate Sampling System for Shuttle, Mir and International Space Station

1998-07-13
981764
Archival sampling of potable water and condensate for ground laboratory analysis has been an important part of the Shuttle-Mir program because of coolant leaks and other events on Mir that have affected water quality. We report here the development of and preliminary results from a novel device for single phase humidity condensate collection at system pressures. The sampler consists of a commercial-off-the-shelf Teflon® bladder and a custom reinforced Nomex® restraint that is sized properly to absorb the stress of applied pressures. A plastic Luer-Lock disconnect, with poppet actuated by a mating Luer-Lock fitting, prevents the contents from being spilled during transport. In principle, a sampler of any volume can be designed. The empty mass of the reusable one-liter sampler is only 63 grams. Several designs were pressure tested and found to withstand more than 3 atmospheres well in excess of typical spacecraft water or wastewater system pressures.
Technical Paper

Total Organic Carbon Analyzer For ISS

1998-07-13
981765
On the International Space Station (ISS), atmospheric humidity condensate and other waste waters will be recycled and treated to produce potable water for use by the crews. Space Station requirements include an on-orbit capability for real-time monitoring of key water quality parameters, such as total organic carbon (TOC), total inorganic carbon (TIC), total carbon (TC), pH, and conductivity, to ensure that crew health is protected during consumption of reclaimed water. The Crew Health Care System (CHeCS) for ISS includes an analyzer that has been designed to meet this requirement. The analyzer is adapted from commercially successful technology, and it measures TOC and TIC throughout the range from 1 to 50,000 μg/L, and TC from 1 to 100,000 μg/L. It measures pH between 2.0 and 12.0 pH units, and conductivity from 0.1 to 300 μmho/cm. The analyzer is scheduled for launch to ISS on mission 2A.1.
Technical Paper

Colorimetric-Solid Phase Extraction (C-SPE): In-Flight Methodologies for the Facile Determination of Trace Level Indicators of Water Quality

2008-06-29
2008-01-2201
At present, spacecraft water quality is assessed when samples collected on the International Space Station (ISS) are returned to Earth. Several months, however, may pass between sample collection and analysis, potentially compromising sample integrity by risking degradation. For example, iodine and silver, which are the respective biocides used in the U.S. and Russian spacecraft potable water systems, must be held at levels that prevent bacterial growth, while avoiding adverse effects on crew health. A comparable need exists for the detection of many heavy metals, toxic organic compounds, and microorganisms. Lead, cadmium, and nickel have been found, for instance, in the ISS potable water system at amounts that surpass existent requirements. There have been similar occurrences with hazardous organic compounds like formaldehyde and ethylene glycol. Microorganism counts above acceptable limits have also been reported in a few instances.
Technical Paper

Archiving Trace Organic Contaminants in Spacecraft Water

2003-07-07
2003-01-2408
One of the long-standing concerns in space exploration is the presence of trace organic contaminants in recycled spacecraft water supplies. At present, water samples on the International Space Station (ISS) are collected at regular intervals, stored in Teflon™-lined containers, and returned to Earth for characterization. This approach, while effective in defining water quality, has several notable problems. First, this method of archiving removes a significant volume of the ISS water supply. Second, the archived water consumes valuable cargo space in returning Shuttle and Soyuz vehicles. Third, the organic contaminants present in the collected samples may degrade upon extended storage. The latter problem clearly compromises sample integrity. Upon return to Earth, sample degradation is minimized by refrigeration. Due to present resource constraints, however, refrigeration is not a viable option in space.
Technical Paper

Rapid Determination of Biocide Concentrations Using Colorimetric Solid Phase Extraction (C-SPE): Results from Microgravity Testing

2003-07-07
2003-01-2406
A sorption-spectrophotometric platform for the concentration and subsequent quantification of biocides in spacecraft drinking water is described. This methodology, termed Colorimetric Solid Phase Extraction (C-SPE), is based on the extraction of analytes onto a membrane impregnated with a colorimetric reagent. Quantification of the extracted analytes is accomplished by interrogating the surface of the membrane with a commercially available diffuse reflectance spectrophotometer. Ground-based experiments have shown that C-SPE is a viable means to determine biocide concentrations in the range commonly found in water samples from the Space Shuttle and the International Space Station (ISS). This paper details efforts to advance C-SPE closer to space flight qualification and ISS implementation, starting with the modification of the ground based biocide detection platform to simplify operation in a microgravity environment.
Technical Paper

ISS Total Organic Carbon Analyzer Status Update - 2003

2003-07-07
2003-01-2403
The Crew Health Care System (CHeCS) is responsible for providing environmental monitoring to protect crew health, including in-flight chemical water quality analysis. To meet this objective, Total Organic Carbon Analyzer (TOCA) Serial Number (SN) 1002 was launched to the International Space Station (ISS) in April of 2001 as part of the CHeCS hardware. Since that time it has been used to evaluate the quality of the potable water supplies consisting of reprocessed atmospheric condensate water, Shuttle-transferred water, and ground-supplied water. Potable water is available for crew use from the Service Module System for Regeneration of Water from Condensate (SRV-K) galley hot and warm ports and the Stored Potable Water System (SVO-ZV) port. Potable water samples are periodically collected from each of these ports for in-flight analysis with the TOCA.
Technical Paper

ISS Total Organic Carbon Analyzer - 2002 Status

2002-07-15
2002-01-2533
Potable water supplies onboard the International Space Station (ISS) include both reclaimed water from treatment of atmospheric humidity condensate and stored water that is either Shuttle-transferred or ground-supplied. Space station medical operations requirements call for real-time monitoring of key water quality parameters, such as total organic carbon, total inorganic carbon, total carbon, pH, and conductivity, to ensure that crew health is protected from unsafe drinking water. A Total Organic Carbon Analyzer (TOCA) designed to meet these requirements was developed as part of the Crew Health Care System and launched to the ISS in April of 2001. The initial design of the ISS TOCA was previously presented at this conference in 1998. The current design of the instrument includes an improved reagent system and upgraded software to enhance accuracy through the capability to measure organic contamination of the reagents and correct analytical results.
Technical Paper

ISS Expeditions 10 & 11 Potable Water Sampling and Chemical Analysis Results

2006-07-17
2006-01-2015
During the twelve month period comprising Expeditions 10 and 11, the chemical quality of the potable water onboard the International Space Station (ISS) was verified through the return and ground analysis of water samples. The two-man Expedition 10 crew relied solely on Russian-provided ground water and reclaimed cabin humidity condensate as their sources of potable water. Collection of archival water samples with U.S. hardware has remained extremely restricted since the Columbia tragedy because of very limited return volume on Russian Soyuz vehicles. As a result only two such samples were collected during Expedition 10 and returned on Soyuz 9. The average return sample volume was only 250 milliliters, which limited the breadth of chemical analysis that could be performed. Despite the Space Shuttle vehicle returning to flight in July 2005, only two potable water samples were collected with U.S. hardware during Expedition 11 and returned on Shuttle flight STS-114 (LF1).
Technical Paper

Further Characterization and Multifiltration Treatment of Shuttle Humidity Condensate

1995-07-01
951685
On the International Space Station (ISS), humidity condensate will be collected from the atmosphere and treated by multifiltration to produce potable water for use by the crews. Ground-based development tests have demonstrated that multifiltration beds filled with a series of ion-exchange resins and activated carbons can remove many inorganic and organic contaminants effectively from wastewaters. As a precursor to the use of this technology on the ISS, a demonstration of multifiltration treatment under microgravity conditions was undertaken. On the Space Shuttle, humidity condensate from cabin air is recovered in the atmosphere revitalization system, then stored and periodically vented to space vacuum. A Shuttle Condensate Adsorption Device (SCAD) containing sorbent materials similar to those planned for use on the ISS was developed and flown on STS-68 as a continuation of DSO 317, which was flown initially on STS-45 and STS-47.
Technical Paper

A Total Organic Carbon Analyzer for Space Potable Water Systems

1996-07-01
961570
A Total Organic Carbon (TOC) Analyzer has been developed for a Life Sciences Risk Mitigation Flight Experiment to be conducted on Spacehab and the Russian space station, Mir. Initial launch is scheduled for December 1996 (flight STS-81). The analyzer will be tested on the Orbiter in the Spacehab module, including when the Orbiter is docked at the Mir space station. The analyzer is scheduled to be launched again in May 1997 (STS-84) when it will be transferred to Mir. During both flights the analyzer will measure the quality of recycled and ground-supplied potable water on the space station. Samples will be archived for later return to the ground, where they will be analyzed for comparison to in-flight results. Water test samples of known composition, brought up with the analyzer, also will be used to test its performance in microgravity. Ground-based analyses of duplicates of those test samples will be conducted concurrently with the in-flight analyses.
Technical Paper

Chemical Analysis of ISS Potable Water From Expeditions 8 and 9

2005-07-11
2005-01-2885
With the Shuttle fleet grounded, limited capability exists to resupply in-flight water quality monitoring hardware onboard the International Space Station (ISS). As such, verification of the chemical quality of the potable water supplies on ISS has depended entirely upon the collection, return, and ground-analysis of archival water samples. Despite the loss of Shuttle-transferred water as a water source, the two-man crews during Expedition 8 and Expedition 9 maintained station operations for nearly a year relying solely on the two remaining sources of potable water; reclaimed humidity condensate and Russian-launched ground water. Archival potable water samples were only collected every 3 to 4 months from the systems that regenerate water from condensate (SRV-K) and distribute stored potable water (SVO-ZV).
Technical Paper

Trace Level Determination of Lead(II) in Water by Colorimetric-Solid Phase Extraction

2005-07-11
2005-01-2889
Preliminary results on the development of quick, simple analytical method for the low level of lead(II) in water samples are described. The method concentrates lead(II) on a small solid-phase extraction disk, which is then quantified directly on the disk by diffuse reflectance spectroscopy (DRS). This method, termed colorimetric solid-phase extraction (C-SPE), requires only 1–2 min for complete workup and is suitable for use in a wide range of applications, including the microgravity environment on the International Space Station. The procedure first adds an excess of potassium iodide to a 10.0 mL sample at a pH of 3.0–3.5 to produce the anionic PbI42− colored complex, which is exhaustively extracted by the disk that was previously impregnated with cetylpyridinium chloride (CPC). The amount of complex extracted is then determined at 420 nm by a hand-held DRS instrument.
Technical Paper

Detection of Cadmium(II) in Water Using Colorimetric-Solid Phase Extraction

2005-07-11
2005-01-2890
Contamination of spacecraft water by heavy metals, such as cadmium and lead, is of growing concern. As a consequence, there is need for a rapid, on-board, easy-to-use method for the determination of cadmium(II) at low ppb levels in spacecraft drinking water supplies. This paper describes the preliminary development of a method for the selective, low level determination of cadmium(II) based on colorimetric-solid phase extraction (C-SPE) [1, 2]. In C-SPE, an analyte is extracted from a water sample onto a membrane that has been previously impregnated with a colorimetric reagent, and then quantified as its colorimetric complex directly on the membrane surface using diffuse reflectance spectroscopy. Results from preliminary tests that screened the performance of 1-(4-nitrophenyl)-3-(4-phenyl-azophenyl)triazene (cadion), and organic dyes, rhodamine B, brilliant green, and methyl violet as colorimetric reagents for potential use in a C-SPE analysis of cadmium(II) are described.
Technical Paper

Development of Streamlined Methods for Integration into Multiplexed Colorimetric Solid Phase Extraction (MC-SPE) Analysis of Spacecraft Water

2005-07-11
2005-01-2891
The need to preserve crew health during space missions, combined with the level of demand on both crew time and cargo space, dictates the development of fast, facile methods capable of monitoring trace quantities of several analytes in spacecraft water. This presentation describes our efforts to address this need by using Multiplexed Colorimetric Solid Phase Extraction (MC-SPE). MC-SPE is a sorption-spectrophotometric platform based upon the extraction of analytes onto membranes impregnated with selective colorimetric agents. Quantification is accomplished using Kubelka-Munk values calculated from the diffuse reflectance spectrum of the complex on the surface of the membrane and calibration curves. In traditional C-SPE, concentration factors of up to 1000 can be realized for a single analysis, yielding low detection limits (ppb – ppm range) with a total analysis time of 75–90 s. Herein, we describe the performance and continued refinement of the MC-SPE platform.
Technical Paper

Development of New Detection Schemes Using Colorimetric-Solid Phase Extraction for Formaldehyde and other Trace Organic Contaminants in Water

2005-07-11
2005-01-3063
Space exploration by humans requires maintenance of an adequate potable water supply. Biocide levels must therefore be kept within allowable limits to prevent bacterial growth without causing adverse effects on crew health. Likewise, contaminants such as heavy metals and toxic organic compounds must be held at or below acceptable limits. Currently, spacecraft water quality analyses are performed on samples collected on the International Space Station and returned to Earth. Several months, however, can pass between sample collection and analysis, which may compromise sample integrity due to degradation. These delays also inhibit implementation of real time correction scenarios. There is, therefore, a critical need for rapid, on-board methods for monitoring trace quantities of several analytes in spacecraft drinking water supplies.