Refine Your Search

Topic

Author

Affiliation

Search Results

Technical Paper

Comparison of PMHS, WorldSID, and THOR-NT Responses in Simulated Far Side Impact

2007-10-29
2012-01-1537
Injury to the far side occupant has been demonstrated as a significant portion of the total trauma in side impacts. The objective of the study was to determine the response of PMHS in far side impact configurations, with and without generic countermeasures, and compare responses to the WorldSID and THOR dummies. A far side impact buck was designed for a sled test system that included a center console and three-point belt system. The buck allowed for additional options of generic countermeasures including shoulder or thorax plates or an inboard shoulder belt. The entire buck could be mounted on the sled in either a 90-degree (3-o'clock PDOF) or a 60-degree (2-o'clock PDOF) orientation. A total of 18 tests on six PMHS were done to characterize the far side impact environment at both low (11 km/h) and high (30 km/h) velocities. WorldSID and THOR-NT tests were completed in the same configurations to conduct matched-pair comparisons.
Technical Paper

Assessing Submarining and Abdominal Injury Risk in the Hybrid III Family of Dummies: Part II - Development of the Small Female Frangible Abdomen

1990-10-01
902317
The Frangible Abdomen is a crushable Styrofoam insert for the abdominal region of the Hybrid III family of dummies, which has biofidelity, and assesses the occurrence of submarining and its risk of injury. It was first developed for the mid-sized male Hybrid III dummy. This paper describes the design of the Frangible Abdomen for the small female Hybrid III dummy, and how to use it to assess the occurrence and the risk of injury from submarining. The force-deflection properties of the mid-sized male insert were scaled to the small female dimension using equal stress/equal velocity scaling. Sled tests were run to compare the kinematic and dynamic performance of the baseline small female Hybrid III dummy with the same dummy modified to incorporate the Frangible Abdomen. The kinematic and submarining performance of the small female Hybrid III dummy was unchanged by the addition of the Frangible Abdomen. The Frangible Abdomen was easy to install and use, and had excellent repeatability.
Technical Paper

Biomechanical Analysis of Knee Impact in Frontal Collisions through Finite Element Simulations with a Full Human Body Model

2008-06-17
2008-01-1887
This study applies a detailed finite element model of the human body to simulate occupant knee impacts experienced in vehicular frontal crashes. The human body model includes detailed anatomical features of the head, neck, chest, thoracic and lumbar spine, abdomen, and lower and upper extremities. The material properties used in the model for each anatomic part of the human body were obtained from test data reported in the literature. The total human body model used in the current study has been previously validated in frontal and side impacts. Several cadaver knee impact tests representing occupants in a frontal impact condition were simulated using the previously validated human body model. Model impact responses in terms of force-time and acceleration-time histories were compared with test results. In addition, stress distributions of the patella, femur, and pelvis were reported for the simulated test conditions.
Technical Paper

SID-IIs Beta+-Prototype Dummy Biomechanical Responses

1998-11-02
983151
This paper presents the results of biomechanical testing of the SID-IIs beta+-prototype dummy by the Occupant Safety Research Partnership. The purpose of this testing was to evaluate the dummy against its previously established biomechanical response corridors for its critical body regions. The response corridors were scaled from the 50th percentile adult male corridors defined in International Standards Organization Technical Report 9790 to corridors for a 5th percentile adult female, using established International Standards Organization procedures. Tests were performed for the head, neck, shoulder, thorax, abdomen and pelvis regions of the dummy. Testing included drop tests, pendulum impacts and sled tests. The biofidelity of the SID-IIs beta+-prototype was calculated using a weighted biomechanical test response procedure developed by the International Standards Organization.
Technical Paper

Head-Neck Kinematics in Dynamic Forward Flexion

1998-11-02
983156
Two-dimensional film analysis was conducted to study the kinematics of the head and neck of 17 restrained human volunteers in 24 frontal impacts for acceleration levels from 6g to 15g. The trajectory of the head center of gravity relative to upper torso reference points and the rotation of head and neck relative to the lower torso during the forward motion phase were of particular interest. The purpose of the study was to analyze the head-neck kinematics in the mid-sagittal plane for a variety of human volunteer frontal sled tests from different laboratories using a common analysis method for all tests, and to define a common response corridor for the trajectory of the head center-of-gravity from those tests.
Technical Paper

Laboratory Experience with the IR-TRACC Chest Deflection Transducer

2002-03-04
2002-01-0188
In 1998, Rouhana et al. described development of a new device, called the IR-TRACC (InfraRed - Telescoping Rod for Assessment of Chest Compression). In its original concept, the IR-TRACC uses two infrared LEDs inside of a telescoping rod to measure deflection. One LED serves as a light transmitter and the other as a light receiver. The output from the receiver LED is converted to a linear function of chest compression using an analog circuit. Tests have been performed with IR-TRACC units at various labs around the world since 1998. A first-generation IR-TRACC system was retrofit into a Q3 dummy by TNO. Similarly, a mid sized male Hybrid III dummy thorax and a small female Hybrid III dummy thorax have been designed by First Technology Safety Systems (FTSS) such that each contains 4 second-generation IR-TRACC units. The second-generation IR-TRACC is the result of continued development by FTSS, especially in the areas of the analysis circuit, manufacturing and calibration methods.
Technical Paper

Development of an Advanced ATD Thorax System for Improved Injury Assessment in Frontal Crash Environments

1992-11-01
922520
Injuries to the thorax and abdomen comprise a significant percentage of all occupant injuries in motor vehicle accidents. While the percentage of internal chest injuries is reduced for restrained front-seat occupants in frontal crashes, serious skeletal chest injuries and abdominal injuries can still result from interaction with steering wheels and restraint systems. This paper describes the design and performance of prototype components for the chest, abdomen, spine, and shoulders of the Hybrid III dummy that are under development to improve the capability of the Hybrid III frontal crash dummy with regard to restraint-system interaction and injury-sensing capability.
Technical Paper

Comparison of Belted Hybrid III, THOR, and Cadaver Thoracic Responses in Oblique Frontal and Full Frontal Sled Tests

2003-03-03
2003-01-0160
This paper compares restrained Hybrid III and THOR thoracic kinematics and cadaver injury outcome in 30° oblique frontal and in full frontal sled tests. Peak shoulder belt tension, the primary source of chest loading, changed by less than four percent and peak chest resultant acceleration changed by less than 10% over the 30° range tested. Thoracic kinematics were likewise insensitive to the direction of the collision vector, though they were markedly different between the two dummies. Mid-sternal Hybrid III chest deflection, measured by the standard sternal potentiometer and by supplemental internal string potentiometers, was slightly lower (∼10%) in the oblique tests, but the oblique tests produced a negligible increase in lateral movement of the sternum. In an attempt to understand the biofidelity of these dummy responses, a series of 30-km/h human cadaver tests having several collision vectors (0°, 15°, 30°, 45°) was analyzed.
Technical Paper

Age Effects on Thoracic Injury Tolerance

1996-11-01
962421
It is well known that the ability of the human body to withstand trauma is a function of its inherent strength, i.e., the strength of the bones and soft tissues. Yet, the properties of the bones and tissues change as a function of the individual's age. In this paper age effects on thoracic injury tolerances are studied by analyzing the mechanical properties of human bones and soft tissues and by examining experimental results found in the literature of thoracic impact tests to human cadavers. This work suggests that the adult age range can be divided into three age groups. Using piece-wise linear regression analyses, it has been determined that the reduction in injury tolerance from the “young” age group to the “elderly” group is approximately 20% under blunt frontal impact loading conditions and is as much as 70% under belt loading conditions.
Technical Paper

Development of a New Standard for Measurement of Impulse Noise Associated With Automotive Inflatable Devices

2005-05-16
2005-01-2398
The SAE Recommended Practice for measuring impulse noise from airbags, SAE J247, “Instrumentation for Measuring Acoustic Impulses within Vehicles”, was first published in 1971 and last affirmed in 1987. Many advances have occurred in understanding and technology since that time. Work in the automotive industry to investigate the characteristics of noise from airbag deployments has shown that large components of low frequency noise can be present when an airbag deploys in a closed vehicle. Others have shown that this low frequency noise can have a protective effect on the ear. Likewise, work for many years at the US Army Research Lab has investigated the risk of hearing loss for a human subjected to an acoustic impulse. That research led to the creation and validation of a mathematical model of the human ear, called Auditory Hazard Assessment Algorithm - Human (AHAAH).
Technical Paper

Elimination of Thoracic Muscle Tensing Effects for Frontal Crash Dummies

2005-04-11
2005-01-0307
Current crash dummy biofidelity standards include the estimated effects of tensing the muscles of the thorax. This study reviewed the decision to incorporate muscle tensing by examining relevant past studies and by using an existing mathematical model of thoracic impacts. The study finds evidence that muscle tensing effects are less pronounced than implied by the biofidelity standard response corridors, that the response corridors were improperly modified to include tensing effects, and that tensing of other body regions, such as extremity bracing, may have a much greater effect on the response and injury potential than tensing of only the thoracic musculature. Based on these findings, it is recommended that muscle tensing should be eliminated from thoracic biofidelity requirements until there is sufficient information regarding multi-region muscle tensing response and the capability to incorporate this new data into a crash dummy.
Technical Paper

A Method for the Experimental Investigation of Acceleration as a Mechanism of Aortic Injury

2005-04-11
2005-01-0295
Rupture of the thoracic aorta is a leading cause of rapid fatality in automobile crashes, but the mechanism of this injury remains unknown. One commonly postulated mechanism is a differential motion of the aortic arch relative to the heart and its neighboring vessels caused by high-magnitude acceleration of the thorax. Recent Indy car crash data show, however, that humans can withstand accelerations exceeding 100 g with no injury to the thoracic vasculature. This paper presents a method to investigate the efficacy of acceleration as an aortic injury mechanism using high-acceleration, low chest deflection sled tests. The repeatability and predictability of the test method was evaluated using two Hybrid III tests and two tests with cadaver subjects. The cadaver tests resulted in sustained mid-spine accelerations of up to 80 g for 20 ms with peak mid-spine accelerations of up to 175 g, and maximum chest deflections lower than 11% of the total chest depth.
Technical Paper

Assessing Submarining and Abdominal Injury Risk in the Hybrid III Family of Dummies

1989-10-01
892440
This paper details the development of an abdominal injury assessment device for loading due to belt restraint submarining in the Hybrid III family of dummies. The design concept and criteria, response criteria, choice of injury criterion, and validation are explained. Conclusions of this work are: 1) Abdominal injury assessment for belt loading due to submarining is now possible in the Hybrid III family of dummies. 2) The abdomen developed has biofidelity in its force deflection characteristics for belt loading, is capable of detecting the occurrence of submarining, and can be used to determine the probability of abdominal injury when submarining occurs. 3) Installation of the abdomen in the Hybrid III dummy does not change the dummy kinematics when submarining does not occur. 4) When submarining does occur, the dummy kinematics are very similar to baseline Hybrid III kinematics, except for torso angle.
Technical Paper

Assessment of Lap-ShouIder Belt Restraint Performance in Laboratory Testing

1989-10-01
892439
Hyge sled tests were conducted using a rear-seat sled fixture to evaluate submarining responses (the lap belt of a lap-shoulder belt restraint loads the abdominal region instead of the pelvis). Objectives of these tests included: an evaluation of methods to determine the occurrence of submarining; an investigation into the influence of restraint system parameters, test severity, and type of anthropomorphic test device on submarining response; and an exploration of the mechanics of submarining. This investigation determined that: 1. Slippage of the lap belt off the pelvis due to dynamic loading of the dummy and the resulting kinematics can cause abdominal loading to the dummy in laboratory crash testing. 2. The 5th female dummy submarined more easily than did the Hybrid ill in the test environment. 3. Motion of the pelvis was controlled using a “pelvic stop”, which reduced the submarining tendency for both the 5th female and Hybrid III dummies. 4.
Technical Paper

Determination of Impact Responses of ES-2re and SID-IIs - Part III: Development of Transfer Functions

2018-04-03
2018-01-1444
An understanding of stiffness characteristics of different body regions, such as thorax, abdomen and pelvis of ES-2re and SID-IIs dummies under controlled laboratory test conditions is essential for development of both compatible performance targets for countermeasures and occupant protection strategies to meet the recently updated FMVSS214, LINCAP and IIHS Dynamic Side Impact Test requirements. The primary purpose of this study is to determine the transfer functions between the ES-2re and SID-IIs dummies for different body regions under identical test conditions using flat rigid wall sled tests. The experimental set-up consists of a flat rigid wall with five instrumented load-wall plates aligned with dummy’s shoulder, thorax, abdomen, pelvis and femur/knee impacting a stationary dummy seated on a rigid low friction seat at a pre-determined velocity.
Technical Paper

Determination of Impact Responses of ES-2re and SID-IIs - Part I: ES-2re

2018-04-03
2018-01-1449
The main purpose of this study was to determine the impact responses of the different body regions (shoulder, thorax, abdomen and pelvis/leg) of the ES-2re and SID-IIs dummies using rigid wall impacts under different initial test conditions. The experimental set-up consisted of a flat rigid wall with five instrumented load-wall plates aligned with dummy’s shoulder, thorax, abdomen, pelvis and knee impacting a stationary dummy seated on a rigid seat at a pre-determined velocity. The relative location and orientation of the load-wall plates was adjusted relative to the body regions of the ES-2re and SID-IIs dummies respectively.
Technical Paper

Biomechanics of 4-Point Seat Belt Systems in Frontal Impacts

2003-10-27
2003-22-0017
The biomechanical behavior of 4-point seat belt systems was investigated through MADYMO modeling, dummy tests and post mortem human subject tests. This study was conducted to assess the effect of 4-point seat belts on the risk of thoracic injury in frontal impacts, to evaluate the ability to prevent submarining under the lap belt using 4-point seat belts, and to examine whether 4-point belts may induce injuries not typically observed with 3-point seat belts. The performance of two types of 4-point seat belts was compared with that of a pretensioned, load-limited, 3-point seat belt. A 3-point belt with an extra shoulder belt that “crisscrossed” the chest (X4) appeared to add constraint to the torso and increased chest deflection and injury risk. Harness style shoulder belts (V4) loaded the body in a different biomechanical manner than 3-point and X4 belts.
Technical Paper

Thoracic Response to Dynamic, Non-Impact Loading from a Hub, Distributed Belt, Diagonal Belt, and Double Diagonal Belts

2004-11-01
2004-22-0022
This paper presents thoracic response corridors developed using fifteen post-mortem human subjects (PMHS) subjected to single and double diagonal belt, distributed, and hub loading on the anterior thorax. We believe this is the first study to quantify the force-deflection response of the same thorax to different loading conditions using dynamic, non-impact, restraint-like loading. Subjects were positioned supine on a table and a hydraulic master-slave cylinder arrangement was used with a high-speed materials testing machine to provide controlled chest deflection at a rate similar to that experienced by restrained PMHS in a 48-km/h sled test. All loading conditions were tested at a nominally non-injurious level initially. When the battery of non-injurious tests was completed, a single loading condition was used for a final, injurious test (nominal 40% chest deflection).
Technical Paper

Development of a Reusable, Rate-Sensitive Abdomen for the Hybrid III Family of Dummies

2001-11-01
2001-22-0002
The objective of this work was to develop a reusable, rate-sensitive dummy abdomen with abdominal injury assessment capability. The primary goal for the abdomen developed was to have good biofidelity in a variety of loading situations that might be encountered in an automotive collision. This paper presents a review of previous designs for crash dummy abdomens, a description of the development of the new abdomen, results of testing with the new abdomen and instrumentation, and suggestions for future work. The biomechanical response targets for the new abdomen were determined from tests of the mid abdomen done in a companion biomechanical study. The response of the abdominal insert is an aggregate response of the dummy’s entire abdominal area and does not address differences in upper versus lower abdominal response, solid versus hollow organs, or organ position or mobility.
Technical Paper

Prediction of Airbag-Induced Forearm Fractures and Airbag Aggressivity

2001-11-01
2001-22-0024
This study continued the biomechanical investigations of forearm fractures caused by direct loading of steering-wheel airbags during the early stages of deployment. Twenty-four static deployments of driver airbags were conducted into the forearms of unembalmed whole cadavers using a range of airbags, including airbags that are depowered as allowed by the new federal requirements for frontal impact testing. In general, the depowered airbags showed a reduction in incidence and severity of forearm fractures compared to the pre-depowered airbags tested. Data from these twenty-four tests were combined with results from previous studies to develop a refined empirical model for fracture occurrence based on Average Distal Forearm Speed (ADFS), and a revised value for fifty-percent probability of forearm-bone fracture of 10.5 m/s. Bone mineral content, which is directly related to forearm tolerance, was found to be linearly related to arm mass.