Refine Your Search

Search Results

Standard

Type "F" Clamps for Plumbing Applications

2008-12-02
CURRENT
J1670_200812
This SAE Standard covers complete dimensional and general specifications for worm drive hose clamps for general use in the plumbing industry.
Standard

Recommended Practices for Design and Evaluation of Passenger and Light Truck Coolant Hose Clamped Joints

2013-07-09
CURRENT
J1697_201307
This SAE Recommended Practice covers recommended practices for design and evaluation of hose clamped joints primarily in automotive applications. It is intended to: (a) evaluate current joint designs, (b) compare existing designs, (c) aid in the development of new designs, (d) give objective results once weights are set, (e) rate the overall design and individual sections of design, and (f) encourage future research by industry and the OEM's.
Standard

Transmission Oil Cooler Hose

2014-06-04
CURRENT
J1532_201406
This SAE Standard covers hose intended for use with automatic transmission cooling system applications. Type A hoses are intended for original equipment or replacement applications while Type B hoses are intended for aftermarket auxiliary cooler applications only. The reference fluid for tests requiring the use of automatic transmission fluid (ATF) shall be Dexron III / Mercon 5 or equivalent ATF that is agreed to by hose manufacturer and customer.
Standard

SAE Hose Measurement Study

2015-04-21
CURRENT
J1759_201504
The Measurement of Coolant Hose task group conducted a round-robin study to determine the measuring capability of automotive suppliers and users to measure Inside Diameter (ID), Outside Diameter (OD), Wall Thickness (Wall) and wall thickness variation of hose using traditional measuring devices and techniques. Seven companies (five suppliers and two end users) participated in this testing. Based upon the round-robin study this information report will detail procedures, test measuring devices, results and recommendations.
Standard

SAE Hose Measurement Study

2006-01-04
HISTORICAL
J1759_200601
The Measurement of Coolant Hose task group conducted a round-robin study to determine the measuring capability of automotive suppliers and users to measure Inside Diameter (ID), Outside Diameter (OD), Wall Thickness (Wall) and wall thickness variation of hose using traditional measuring devices and techniques. Seven companies (five suppliers and two end users) participated in this testing. Based upon the round-robin study this information report will detail procedures, test measuring devices, results and recommendations.
Standard

SAE Hose Measurement Study

2000-10-01
HISTORICAL
J1759_200010
The Measurement of Coolant Hose task group conducted a round-robin study to determine the measuring capability of automotive suppliers and users to measure Inside Diameter (ID), Outside Diameter (OD), Wall Thickness (Wall) and wall thickness variation of hose using traditional measuring devices and techniques. Seven companies (five suppliers and two end users) participated in this testing. Based upon the round-robin study this information report will detail procedures, test measuring devices, results and recommendations.
Standard

Compression Set of Hoses or Solid Discs

2015-04-21
CURRENT
J1638_201504
This SAE Recommended Practice is used for establishing the compression set that could be expected to occur with a thermoset elastomeric hose under securing clamps. It seeks to reproduce the type of indentation caused by the clamps in the wall of a hose. An excessive compression set measured by this method may indicate a hose that could eventually allow leakage of fluid or gas past the clamps in service.
Standard

Compression Set of Hoses or Solid Discs

2004-11-30
HISTORICAL
J1638_200411
This SAE Recommended Practice is used for establishing the compression set that could be expected to occur with engine coolant hoses under securing clamps. It seeks to reproduce the type of indentation caused by the clamps in the wall of the hose. An excessive compression set measured by this method would indicate a hose that could eventually alloy leakage of coolant past the clamps in service. This method has been found to give repeatable results in the range of 25% to 50% initial compression.
Standard

Compression Set of Hoses Or Solid Discs

1993-05-01
HISTORICAL
J1638_199305
This SAE Recommended Practice is used for establishing the compression set that could be expected to occur with engine coolant hoses under securing clamps. It seeks to reproduce the type of indentation caused by the clamps in the wall of the hose. An excessive compression set measured by this method would indicate a hose that could eventually alloy leakage of coolant past the clamps in service. This method has been found to give repeatable results in the range of 25% to 50% initial compression.
Standard

Coolant Hose - Normal Service Type Convoluted, Wire Support Hose (Supplement to SAE J20)

2001-11-21
HISTORICAL
J20/2_200111
This SAE Standard provides ordering information for any SAE 20R5 hose type (such as "EC, HT, LT" or combination thereof.) This is a wire-reinforced hose for coolant circulating systems of automotive type engines. This hose consists of a convoluted section with plain ends. The hose shall contain a wire helix or helices in the convoluted section. It is a supplement for Government use but may be used by others.
Standard

Coolant Hose - Normal Service Type Convoluted, Wire Support Hose (Supplement to SAE J20 for Government Use Replacing Part of MS51008)

2018-03-04
CURRENT
J20/2_201803
This SAE Standard provides ordering information for any SAE 20R5 hose type (such as “EC, HT, LT” or combination thereof.) This is a wire-reinforced hose for coolant circulating systems of automotive type engines. This hose consists of a convoluted section with plain ends. The hose shall contain a wire helix or helices in the convoluted section. It is a supplement for Government use but may be used by others.
Standard

Coolant Hose—Normal Service Type Convoluted, Wire Support Hose (Supplement to SAE J20 for Government Use Replacing Part of MS51008)

2009-06-04
HISTORICAL
J20/2_200906
This SAE Standard provides ordering information for any SAE 20R5 hose type (such as “EC, HT, LT” or combination thereof.) This is a wire-reinforced hose for coolant circulating systems of automotive type engines. This hose consists of a convoluted section with plain ends. The hose shall contain a wire helix or helices in the convoluted section. It is a supplement for Government use but may be used by others.
Standard

CLAMPING FORCE TEST PROCEDURE

1997-08-01
HISTORICAL
J2371_199708
This SAE Recommended Practice is a test procedure to obtain force data for self-compensating type clamps (SAE Type E, CTB, and CTW).
Standard

Clamping Force Test Procedure

2018-03-04
CURRENT
J2371_201803
This SAE Recommended Practice is a test procedure to obtain force data for self-compensating type clamps (SAE Type E, CTB, and CTW).
Standard

Refrigerant 12 Automotive Air-Conditioning Hose

2015-04-21
CURRENT
J51_201504
This SAE Standard covers reinforced hose, or hose assemblies, intended for conducting liquid and gaseous dichlorodifluoromethane (refrigerant 12) in automotive air-conditioning systems. The hose shall be designed to minimize permeation of refrigerant 12 and contamination of the system and to be serviceable over a temperature range of −30 to 120 °C (−22 to 248 °F). Specific construction details are to be agreed upon between user and supplier.1 NOTE—R12 refrigerant has been placed on a banned substance list due to its ozone depletion characteristics. SAE J51 specification will be phased out as new automotive A/C systems are using R134a. SAE J2064 is the Standard for refrigerant 134a hose. For refrigerant 134a use, refer to SAE J2064.
Standard

Non-Contact Hose Measurement Study 1

2001-08-06
HISTORICAL
J2605_200108
The Hose Measurement Task Force conducted a round-robin study to determine the measuring capability of automotive suppliers and users to simultaneously measure the Inside Diameter (ID), Outside Diameter (OD), Wall Thickness (Wall), and Wall thickness Variation (WV) of hose using a laser-based, non-contact LOTIS QC-20 gauging device. Three (3) companies (all end users) participated in this testing with one of the three companies performing the GR&R calculations presented herein. Based upon the round-robin study this report will detail procedures, test measuring devices, results, and conclusions.
Standard

Non-Contact Hose Measurement Study 1

2015-04-21
CURRENT
J2605_201504
The Hose Measurement Task Force conducted a round-robin study to determine the measuring capability of automotive suppliers and users to simultaneously measure the Inside Diameter (ID), Outside Diameter (OD), Wall Thickness (Wall), and Wall thickness Variation (WV) of hose using a laser-based, non-contact LOTIS QC-20 gauging device. Three (3) companies (all end users) participated in this testing with one of the three companies performing the GR&R calculations presented herein. Based upon the round-robin study this report will detail procedures, test measuring devices, results, and conclusions.
X