Technical Paper
Real-Time Calculation of EGR Rate and Intake Charge Oxygen Concentration for Misfire Detection in Diesel Engines
2011-09-11
2011-24-0149
A new procedure for the real-time estimation of the EGR rate and charge oxygen concentration has been developed, assessed and applied to a low-compression ratio GMPT-E EURO V diesel engine. High EGR rates are usually employed in modern diesel engines to reduce combustion temperatures and NOx emissions, especially at medium-low load and speed conditions. The EGR rate is usually calibrated in steady-state conditions, but, under transient conditions, it can be responsible for misfire occurrence or non optimal combustion cycles, if not properly controlled. In other words, combustion instabilities can occur, especially during tip-in maneuvers, which imply transition from high EGR (low load) to low EGR (high load) rates. Misfire is determined by a temporary reduction in the intake charge oxygen concentration during the closure of the EGR valve.