Refine Your Search

Search Results

Viewing 1 to 3 of 3
Standard

Laboratory Viscosity Measurement of Thickened Aircraft Deicing/Anti-icing Fluids with the Brookfield LV Viscometer

2014-07-22
HISTORICAL
AS9968
This AS describes a standard method for viscosity measurements of thickened (AMS1428) anti-icing fluids. Fluid manufacturers may publish alternate methods for their fluids. In case of conflicting results between the two methods, the manufacturer method takes precedence. To compare viscosities, exactly the same measurement elements (including spindle and container size) must have been used to obtain those viscosities.
Standard

Laboratory Viscosity Measurement of Thickened Aircraft Deicing/Anti-icing Fluids with a Viscometer

2021-07-23
CURRENT
AS9968A
This document describes a standard method for measuring the viscosity of thickened (AMS1428) Type II/III/IV Aircraft Deicing/Anti-icing Fluids. The determination of viscosity for a Non-Newtonian fluid is very sensitive to shear and differences in sample chamber geometry. Even slight differences can have a large effect on measurement results. The test parameters and associated error for this standard are applicable to the Brookfield LV viscometer. A Brookfield LV or equivalent viscometer shall be used. To be considered equivalent, an alternate viscometer must demonstrate statistically equivalent performance, i.e., accuracy and precision when testing thickened (AMS1428) fluids using the same test parameters and conditions.Test parameters and conditions outside of the ranges described within this standard may be used only if they meet minimum limits for precision and accuracy established for the Brookfield LV viscometer.
X