Refine Your Search

Topic

Author

Affiliation

Search Results

Video

SAE Eye on Engineering: Conti's Smart Backup Camera

2018-11-08
Every year in the U.S., about 300 people die, and 15 thousand vehicles suffer accidents, while backing up. In this episode of SAE Eye on Engineering, Editor-in-Chief Lindsay Brooke looks at Continental's new intelligent backup camera that's small in size but huge in capability. SAE Eye on Engineering also airs Monday mornings on WJR 760 AM Detroit's Paul W. Smith Show.
Video

SAE Eye on Engineering: Conti's Virtual A-Pillar tech

2018-11-13
The pillars that frame both sides of your car's windshield are known as the A pillars. In this episode of SAE Eye on Engineering, Editor-in-Chief Lindsay Brooke looks at Continental's new "Virtual" A pillar. SAE Eye on Engineering also airs Monday mornings on WJR 760 AM Detroit's Paul W. Smith Show.
Standard

SAE Electrical Energy Storage Device Labeling Recommended Practice

2012-12-07
CURRENT
J2936_201212
This SAE Recommended Practice provides for labeling guidelines at all levels of component, subsystem and system level architectures describing content, placement and durability requirements of specific unit throughout the total product life cycle from inception to reclamation.
Standard

Spark Arrester Test Carbon

1990-09-01
HISTORICAL
J997_199009
This SAE Standard establishes physical properties required of SAE Coarse Test Carbon and SAE Fine Test Carbon and establishes test methods to ensure that these requirements are met.
Standard

Spark Arrester Test Carbon

1988-06-01
HISTORICAL
J997_198806
This SAE Standard establishes physical properties required of SAE Coarse Test Carbon and SAE Fine Test Carbon and establishes test methods to ensure that these requirements are met.
Standard

Spark Arrester Test Carbon

1988-10-01
HISTORICAL
J997_198810
This SAE Standard establishes physical properties required of SAE Coarse Test Carbon and SAE Fine Test Carbon and establishes test methods to ensure that these requirements are met.
Standard

Fastener Part Standard - Hexagon Socket, Square Head, and Slotted Headless Set Screws - Inch Dimensioned

2016-11-15
CURRENT
J2656_201611
This SAE Part Standard covers selected inch dimensioned set screws manufactured in accordance with American Society for Mechanical Engineers dimensional standards. This SAE standard covers material most often used in ship systems and equipment but its use may be applied wherever fasteners of the covered materials are used. This standard permits the fasteners to be identified and ordered by a part identification number (PIN) as defined in this document.
Standard

Optical Imaging Evaluation of Impact Damage Resistance Testing on Exterior Finishes

2011-05-26
CURRENT
J2661_201105
This SAE Recommended Practice covers a procedure for evaluating plastic and multiple-layer coatings exposed to gravelometer testing (as defined in SAE J400) with an optical imaging and analysis system. The intent of the procedure is to detect, count and characterize instances of damage in the coated surface that fracture the top coat layer or penetrate through multiple layers of the coating system. It may be possible to extend this methodology of coating damage evaluation to specimens that have undergone test procedures or exposures that produce similar, discrete damage sites in the coating system. If so applied, evaluation results must be interpreted with respect to the limitations and intent implied by the original evaluation procedure and its associated rating system, if applicable.
Standard

Definition for Particle Size

2011-06-01
CURRENT
J391_201106
"Effective particle or domain size" is a phrase used in X-ray diffraction literature to describe the size of the coherent regions within a material which are diffracting. Coherency in this sense means diffracting as a unit. Small particle size causes X-ray line broadening and as such can be measured. It has been shown related to substructure as observed in transmission electron microscopy. Particle size is affected by hardening, cold working, and fatigue; conversely, there is increasing evidence that particle size, per se, affects both static and dynamic strength.
Standard

PENETRATING RADIATION INSPECTION

1991-03-01
HISTORICAL
J427_199103
The purpose of this SAE Information Report is to provide basic information on penetrating radiation, as applied in the field of nondestructive testing, and to supply the user with sufficient information so that he may decide whether penetrating radiation methods apply to his particular inspection need. Detailed information references are listed in Section 2.
Standard

Penetrating Radiation Inspection

1988-12-01
HISTORICAL
J427_198812
The purpose of this SAE Information Report is to provide basic information on penetrating radiation, as applied in the field of nondestructive testing, and to supply the user with sufficient information so that he may decide whether penetrating radiation methods apply to his particular inspection need. Detailed information references are listed in Section 2.
Standard

Penetrating Radiation Inspection

1983-06-01
HISTORICAL
J427_198306
The purpose of this SAE Information Report is to provide basic information on penetrating radiation, as applied in the field of nondestructive testing, and to supply the user with sufficient information so that he may decide whether penetrating radiation methods apply to his particular inspection need. Detailed information references are listed in Section 2.