Refine Your Search

Topic

Search Results

Standard

FINE WIRE MESH FOR FILTER ELEMENTS

1989-05-30
HISTORICAL
AIR888A
This AIR discusses the terminology, types, method of manufacture and chemistry of the fine wire meshes used for filtration of hydraulic, lubrication, fuel systems and similar applications. Information contained herein may be used for quality assurance testing to insure that a high performance filter grade wire mesh is acceptable for use in an aerospace application.
Standard

RECOMMENDED STANDARD FOR AEROSPACE FILTER ELEMENT FINE WIRE MESH

2011-02-11
HISTORICAL
AIR888
This AIR discusses the nature, method of manufacture and chemistry of fine wire meshes of the type used for filtration and similar applications, and how this information may be utilized in setting up a quality control program to insure reliability of meshes used for such applications.
Standard

Fine Wire Mesh for Filter Elements

2002-11-14
HISTORICAL
AIR888B
This SAE Aerospace Information Report (AIR) discusses the terminology, types, method of manufacture and chemistry of the fine wire meshes used for filtration of hydraulic, lubrication fuel systems, and similar applications. Information contained herein may be used for quality assurance testing to insure that a high performance filter grade wire mesh is acceptable for use in an aerospace application.
Standard

Fine Wire Mesh for Filter Elements

2012-09-24
CURRENT
AIR888C
This SAE Aerospace Information Report (AIR) discusses the terminology, types, method of manufacture and chemistry of the fine wire meshes used for filtration of hydraulic, lubrication fuel systems, and similar applications. Information contained herein may be used for quality assurance testing to insure that a high performance filter grade wire mesh is acceptable for use in an aerospace application.
Standard

Procedure for the Determination of Particulate Contamination of Air in Dust Controlled Spaces by the Manual Particle Count Method

2001-03-01
HISTORICAL
ARP743B
This SAE Aerospace Recommended Practice (ARP) describes two procedures for sampling particles in dust controlled spaces. One procedure covers airborne dust above 5 μm. The other (and newly added procedure) covers particles of 25 μm and larger that “fall out” of the environment onto surfaces. In each case the particles are sized in the longest dimension and counted. Airborne particles are reported as particles per cubic meter (cubic foot) whereas particles collected in fall out samples are reported as particles per 0.1 square meter (square foot). This document includes English units in parentheses as referenced information to the SI units where meaningful. These procedures may also be used for environmental analysis where the quality of the particles by visual or chemical analysis is intended.
Standard

PROCEDURE FOR THE DETERMINATION OF PARTICULATE CONTAMINATION OF AIR IN DUST CONTROLLED SPACES BY THE PARTICLE COUNT METHOD

1962-08-30
HISTORICAL
ARP743
This test describes a self-checking procedure for the determination of particulate contaminant five microns or greater in size in air by the particle count method. A maximum variation of two to one (±33% of the average of two runs) in results should be expected for replicate counts on the same sample, providing that the procedure is followed closely and the precautions presented regarding check samples and self-checking aspects are observed.
Standard

Aerospace - Dynamic Test Method for Determining the Relative Degree of Cleanliness of the Downstream Side of Filter Elements

2020-05-05
CURRENT
ARP599D
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

Aerospace - Dynamic Test Method for Determining the Relative Degree of Cleanliness of the Downstream Side of Filter Elements

2002-05-21
HISTORICAL
ARP599C
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

AEROSPACE - DYNAMIC TEST METHOD FOR DETERMINING THE RELATIVE DEGREE OF CLEANLINESS OF THE DOWNSTREAM SIDE OF FILTER ELEMENTS

1996-05-01
HISTORICAL
ARP599B
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

DYNAMIC TEST METHOD FOR DETERMINING THE DEGREE OF CLEANLINESS OF THE DOWNSTREAM SIDE OF FILTER ELEMENTS

2011-08-10
HISTORICAL
ARP599A
This test method describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate release rate of the tested filter element under the prevailing conditions of the test and may be used for comparative evaluation of the effectiveness of various cleaning methods or cleanliness of elements as received from manufacturers. Because of the variety of conditions which may exist even under the provisions of this procedure, it is difficult to correlate data from one testing agency to another. The data obtained by this procedure do not necessarily indicate qualitatively or quantitatively, the contamination which may be released by a filter element into the operating fluid during service. When properly conducted, however, the procedure will show marked differences between various cleanliness levels of filter elements.
Standard

A DYNAMIC TEST METHOD FOR DETERMINING THE DEGREE OF CLEANLINESS OF THE DOWNSTREAM SIDE OF FILTER ELEMENTS

1996-05-01
HISTORICAL
ARP599
This test method describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure are intended to be used only for evaluation of the effectiveness of various cleaning treatments, or cleanliness of element as received from manufacturers. The data obtained by this procedure do not necessarily indicate, qualitatively or quantitatively, the contamination which may be released by a filter element into a fluid during service use. Because of the wide variety of conditions which may exist in service applications, it is recommended that the user design and conduct his own particular service performance test. (See paragraph 10.1).
Standard

Filter Patch Testing Procedures for Aerospace Hydraulic Pumps and Motors

1999-07-01
CURRENT
ARP575B
This Aerospace Recommended Practice (ARP) sets forth recommendations of SAE Subcommittee A-6C (Fluid Power Distribution Elements) relative to the procedure and methods to be used in the obtaining and evaluation of filter patch tests for aerospace hydraulic pumps and motors. These patches are to be used in a quality control program to insure that units are operating properly prior to delivery to the customer. This is to promote an optimum in cleanliness standards in aerospace hydraulic circuits. It is expected that this will promote a longer service life of the pump or motor.