Refine Your Search

Topic

Author

Affiliation

Search Results

Standard

Logistics Product Data Reports Handbook

2015-10-21
WIP
TAHB0007_1A
This document describes a set of standardized reports that can be generated using the logistics product data elements contained in GEIA-STD-0007-B. Each report is defined by selection options, processing, format, report sequence, and data sources. The selection options paragraph identifies recommended mandatory and optional selections that can be made by the user to tailor the report content. The processing paragraph identifies qualifying criteria for report data, report calculations, and specific instructions regarding how the data should be presented on the report. Each report has a sample report showing its format. Report sequences specify the sort criteria for a given report, and each Part/Section within a report. There is an attached listing of data sources for the elements that are on a report. The listing provides the report header for each element; and its GEIA-STD-0007-B data element/attribute along with the appropriate entity.
Standard

Discharge Signal Lighting System

2008-09-02
HISTORICAL
J2320_200809
This SAE Recommended Practice applies to motor vehicle signaling and marking devices which use light generated by a discharge source. This document provides test methods, requirements, and guidelines applicable to the unique characteristics of discharge lighting systems and their components. These are in addition to those required for signal and marking devices. This document is intended to be a guide to standard practice and is subject to change to reflect additional experience and technical advances.
Standard

Connections for On-Board Road Vehicle Electrical Wiring Harnesses - Part 2: Tests and General Performance Requirements

2018-10-22
WIP
J2223/2
Procedures included within this specification are intended to cover performance testing at all phases of development, production, and field analysis of electrical terminals, connectors, and components that constitute the electrical connection systems in low voltage (0 - 20 VDC) road vehicle applications. These procedures are only applicable to terminals used for In-Line, Header, and Device Connector systems with and without Shorting Bars. They are not applicable to Edge Board connector systems, greater than 20 VAC or DC, or to eyelet type terminals.
Standard

Connections for On-Board Road Vehicle Electrical Wiring Harnesses—Part 2: Tests and General Performance Requirements

2011-02-18
CURRENT
J2223/2_201102
Procedures included within this specification are intended to cover performance testing at all phases of development, production, and field analysis of electrical terminals, connectors, and components that constitute the electrical connection systems in low voltage (0 - 20 VDC) road vehicle applications. These procedures are only applicable to terminals used for In-Line, Header, and Device Connector systems with and without Shorting Bars. They are not applicable to Edge Board connector systems, > 20 VAC or DC, or to eyelet type terminals.
Video

SAE Eye on Engineering: Ford's new steel-bodied Ranger

2018-11-08
Today, ford motor company begins U.S. production of its 2019 Ranger, the company's first midsize pickup. In this episode of SAE Eye on Engineering, Editor-in-Chief Lindsay Brooke looks at the new steel-bodied Ranger. SAE Eye on Engineering also airs Monday mornings on WJR 760 AM Detroit's Paul W. Smith Show.
Standard

COOLING FLOW MEASUREMENT TECHNIQUES

1992-06-01
HISTORICAL
J2082_199206
This SAE Information Report has been prepared by the Standards Committee on Cooling Flow Measurement (CFM) at the request of the SAE Road Vehicle Aerodynamics Forum Committee (RVAC). The committee was formed in January 1985 for the purpose of investigating what measuring techniques are used by automotive product manufacturers to determine air cooling air flow rates and, if possible, to synthesize these into a recommended practice report. Although a great deal is already known about engine cooling, recent concern with fuel conservation has resulted in generally smaller air intakes whose shape and location are dictated primarily by low vehicle drag/high forward speed requirements. The new vehicle intake configurations make it more difficult to achieve adequate cooling under all conditions. They cause cooling flow velocity profiles to become distorted and underhood temperatures to be excessively high.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2013-04-09
HISTORICAL
J2691_201304
This SAE standard establishes the minimum construction and performance requirements for a 15 Pole Connector Between Towing Vehicles and Trailers, for trucks, trailers, and dollies in conjunction with SAE J2742 “Combination 11 Conductors and 4 Pairs ECBS Cable”. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2018-04-15
CURRENT
J2691_201804
This SAE standard establishes the minimum construction and performance requirements for a 15 Pole Connector Between Towing Vehicles and Trailers, for trucks, trailers, and dollies in conjunction with SAE J2742. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Book

Electronic Transmission Controls

2000-06-10
The evolution of the automotive transmission has changed rapidly in the last decade, partly due to the advantages of highly sophisticated electronic controls. This evolution has resulted in modern automatic transmissions that offer more control, stability, and convenience to the driver. Electronic Transmission Controls contains 68 technical papers from SAE and other international organizations written since 1995 on this rapidly growing area of automotive electronics. This book breaks down the topic into two sections. The section on Stepped Transmissions covers recent developments in regular and 4-wheel drive transmissions from major auto manufacturers including DaimlerChrysler, General Motors, Toyota, Honda, and Ford. Technology covered in this section includes: smooth shift control; automatic transmission efficiency; mechatronic systems; fuel saving technologies; shift control using information from vehicle navigation systems; and fuzzy logic control.
Video

SAE Eye on Engineering: Conti's Virtual A-Pillar tech

2018-11-13
The pillars that frame both sides of your car's windshield are known as the A pillars. In this episode of SAE Eye on Engineering, Editor-in-Chief Lindsay Brooke looks at Continental's new "Virtual" A pillar. SAE Eye on Engineering also airs Monday mornings on WJR 760 AM Detroit's Paul W. Smith Show.
Training / Education

Introduction to Finite Element Analysis

Anytime
Finite Element Analysis (FEA) is a computer-aided engineering (CAE) tool used to analyze how a design reacts under real-world conditions. Useful in structural, vibration, and thermal analysis, FEA has been widely implemented by automotive companies and is used by design engineers as a tool during the product development process. Design engineers analyze their own designs while they are still in the form of easily modifiable CAD models to allow for quick turnaround times and to ensure prompt implementation of analysis results in the design process.
Standard

Measurement of Passenger Compartment Refrigerant Concentrations Under System Refrigerant Leakage Conditions

2011-02-04
CURRENT
J2772_201102
This Standard is restricted to refrigeration circuits that provide air-conditioning for the passenger compartments of passenger and commercial vehicles. This Standard includes analytical and physical test procedures to evaluate concentration inside the passenger compartment. In the early phases of vehicle evaluation, usage of the analytical approach may be sufficient without performing physical tests. The physical test procedure involves releasing refrigerant from an external source to a location adjacent to the evaporator core (inside the HVAC-Module). An apparatus is used to provide a repeatable, calibrated leak rate. If the system has multiple evaporators, leakage could be simulated at any of the evaporator locations. This standard gives detail information on the techniques for measuring R-744 [CO2] and R-1234yf [HFO-1234yf], but the general techniques described here can be used for other refrigerants as well.
Standard

Dynamic Cleat Test with Perpendicular and Inclined Cleats

2013-09-05
CURRENT
J2730_201309
This SAE Recommended Practice describes a test method for measuring the forces and moments generated at a high frequency response spindle when a rolling tire impacts a cleat. The cleat is configured either with its crest perpendicular, 90°, to the path of the tire or optionally with its crest inclined at an angle to the path of the tire. The carriage to which the spindle is attached is rigidly constrained in position during each test condition so as to provide a good approximation to fixed loaded radius operation. The method discussed in this document provides impact force and moment time histories essentially free from variations due to tire non-uniformities. The method applies to any size tire so long as the equipment is properly scaled to conduct the measurements for the intended test tire. The data are suitable for use in determining parameters for road load models and for comparative evaluations of the measured properties in research and development.
Standard

Reflex Reflectors for Use on Vehicles 2032 mm or More in Overall Width

2018-05-02
WIP
J2041
This SAE Standard provides test procedures, requirements, and guidelines for reflex reflectors used on vehicles 2032 mm or more in overall width. Reflex reflectors conforming to these requirements may also be used on vehicles less than 2032 mm in overall width.
X