Refine Your Search

Topic

Author

Affiliation

Search Results

Standard

Discharge Signal Lighting System

2008-09-02
HISTORICAL
J2320_200809
This SAE Recommended Practice applies to motor vehicle signaling and marking devices which use light generated by a discharge source. This document provides test methods, requirements, and guidelines applicable to the unique characteristics of discharge lighting systems and their components. These are in addition to those required for signal and marking devices. This document is intended to be a guide to standard practice and is subject to change to reflect additional experience and technical advances.
Video

SAE Eye on Engineering: Ford's new steel-bodied Ranger

2018-11-08
Today, ford motor company begins U.S. production of its 2019 Ranger, the company's first midsize pickup. In this episode of SAE Eye on Engineering, Editor-in-Chief Lindsay Brooke looks at the new steel-bodied Ranger. SAE Eye on Engineering also airs Monday mornings on WJR 760 AM Detroit's Paul W. Smith Show.
Standard

COOLING FLOW MEASUREMENT TECHNIQUES

1992-06-01
HISTORICAL
J2082_199206
This SAE Information Report has been prepared by the Standards Committee on Cooling Flow Measurement (CFM) at the request of the SAE Road Vehicle Aerodynamics Forum Committee (RVAC). The committee was formed in January 1985 for the purpose of investigating what measuring techniques are used by automotive product manufacturers to determine air cooling air flow rates and, if possible, to synthesize these into a recommended practice report. Although a great deal is already known about engine cooling, recent concern with fuel conservation has resulted in generally smaller air intakes whose shape and location are dictated primarily by low vehicle drag/high forward speed requirements. The new vehicle intake configurations make it more difficult to achieve adequate cooling under all conditions. They cause cooling flow velocity profiles to become distorted and underhood temperatures to be excessively high.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2013-04-09
HISTORICAL
J2691_201304
This SAE standard establishes the minimum construction and performance requirements for a 15 Pole Connector Between Towing Vehicles and Trailers, for trucks, trailers, and dollies in conjunction with SAE J2742 “Combination 11 Conductors and 4 Pairs ECBS Cable”. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2018-04-15
CURRENT
J2691_201804
This SAE standard establishes the minimum construction and performance requirements for a 15 Pole Connector Between Towing Vehicles and Trailers, for trucks, trailers, and dollies in conjunction with SAE J2742. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Video

SAE Eye on Engineering: Conti's Virtual A-Pillar tech

2018-11-13
The pillars that frame both sides of your car's windshield are known as the A pillars. In this episode of SAE Eye on Engineering, Editor-in-Chief Lindsay Brooke looks at Continental's new "Virtual" A pillar. SAE Eye on Engineering also airs Monday mornings on WJR 760 AM Detroit's Paul W. Smith Show.
Standard

Measurement of Passenger Compartment Refrigerant Concentrations Under System Refrigerant Leakage Conditions

2011-02-04
CURRENT
J2772_201102
This Standard is restricted to refrigeration circuits that provide air-conditioning for the passenger compartments of passenger and commercial vehicles. This Standard includes analytical and physical test procedures to evaluate concentration inside the passenger compartment. In the early phases of vehicle evaluation, usage of the analytical approach may be sufficient without performing physical tests. The physical test procedure involves releasing refrigerant from an external source to a location adjacent to the evaporator core (inside the HVAC-Module). An apparatus is used to provide a repeatable, calibrated leak rate. If the system has multiple evaporators, leakage could be simulated at any of the evaporator locations. This standard gives detail information on the techniques for measuring R-744 [CO2] and R-1234yf [HFO-1234yf], but the general techniques described here can be used for other refrigerants as well.
Standard

Reflex Reflectors for Use on Vehicles 2032 mm or More in Overall Width

2018-05-02
WIP
J2041
This SAE Standard provides test procedures, requirements, and guidelines for reflex reflectors used on vehicles 2032 mm or more in overall width. Reflex reflectors conforming to these requirements may also be used on vehicles less than 2032 mm in overall width.
Standard

Top Speed Test Procedure for Electric Motorcycles

2014-02-21
CURRENT
J3007_201402
This SAE Recommended Practice incorporates a track-based test procedure that produces a representative value for vehicle top speed when operating on a level paved road with a fully charged battery.
Standard

School Bus Warning Lamps

1975-02-01
HISTORICAL
J887A_197502
This SAE Standard provides test procedures, requirements and guidelines for red and yellow school bus warning lamps.