Refine Your Search

Search Results

Viewing 1 to 5 of 5
Technical Paper

Studies on AC Suction Line Pressure Drop using 1D Modeling

2013-04-08
2013-01-1503
In an automotive air-conditioning (AC) system, the amount of work done by the compressor is also influenced by the suction line which meters the refrigerant flow. Optimizing the AC suction line routing has thus become an important challenge and the plumbing designers are required to come up with innovative packaging solutions. These solutions are required in the early design stages when prototypes are not yet appropriate. In such scenarios, one-dimensional (1D) simulations shall be employed to compute the pressure drop for faster and economical solution. In this paper, an approach of creating a modeling tool for suction line pressure drop prediction is discussed. Using DFSS approach L12 design iterations are created and simulations are carried out using 1D AMESim software. Prototypes are manufactured and tested on HVAC bench calorimeter. AC suction line pressure drop predicted using the 1D modeling co-related well with the test data and the error is less than 5%.
Technical Paper

Gasoline Combustion Modeling of Direct and Port-Fuel Injected Engines using a Reduced Chemical Mechanism

2013-04-08
2013-01-1098
A set of reduced chemical mechanisms was developed for use in multi-dimensional engine simulations of premixed gasoline combustion. The detailed Primary Reference Fuel (PRF) mechanism (1034 species, 4236 reactions) from Lawrence Livermore National Laboratory (LLNL) was employed as the starting mechanism. The detailed mechanism, referred to here as LLNL-PRF, was reduced using a technique known as Parallel Direct Relation Graph with Error Propagation and Sensitivity Analysis. This technique allows for efficient mechanism reduction by parallelizing the ignition delay calculations used in the reduction process. The reduction was performed for a temperature range of 800 to 1500 K and equivalence ratios of 0.5 to 1.5. The pressure range of interest was 0.75 bar to 40 bar, as dictated by the wide range in spark timing cylinder pressures for the various cases. In order to keep the mechanisms relatively small, two reductions were performed.
Technical Paper

Calibrating an Adaptive Pivoting Vane Pump to Deliver a Stepped Pressure Profile

2013-04-08
2013-01-1729
This paper presents a process for the selection of spring rate and pre-load for an adaptively controlled pivoting vane oil pump. The pivoting vane pump has two modes: high and low speed. A spring within the pump is installed to induce a torque that causes an adaptive displacement mechanism within the pump to move toward maximum oil chamber size. In low speed mode, two feedback regions are pressurized that produce torques that counter the spring generated torque. Together, both regions being pressurized by main oil gallery pressure tend to reduce pump displacement more at lower speeds than if only a single chamber is pressurized. At higher speeds, a solenoid switch turns off pressure to one of the feedback pressure chambers, thereby reducing feedback torque that counters spring torque. This enables higher pressure calibrations in this speed mode. In this paper, we identify a process for choosing the spring rate and pre-load that calibrates the adaptive displacement mechanism.
Technical Paper

CFD Analysis of Various Automotive Bodies in Linear Static Pressure Gradients

2012-04-16
2012-01-0298
Establishing data adjustments that will give an interference free result for bluff bodies in automotive wind tunnels has been pursued for at least the last 45 years. Recently, the Two-Measurement correction method that yields a wake distortion adjustment for open jet wind tunnels has shown promise of being able to adjust for many of the effects of non-ideal static pressure gradients on bluff automotive bodies. Utilization of this adjustment has shown that a consistent drag results when the vehicle is subjected to the various gradients generated in open jet wind tunnels. What has been lacking is whether this consistent result is independent of the other tunnel interference effects. The studies presented here are intended to fill that gap on the performance of the two-measurement technique. The subject CFD studies are designed to eliminate all wind tunnel interference effects except for the variation of the (linear) static pressure gradient.
Technical Paper

CFD Analysis of Automotive Bodies in Static Pressure Gradients

2014-04-01
2014-01-0612
Recently, the Two-Measurement correction method that yields a wake distortion adjustment for open jet wind tunnels has shown promise of being able to adjust for many of the effects of non-ideal static pressure gradients on bluff automotive bodies. Utilization of this adjustment has shown that a consistent drag results when the vehicle is subjected to the various gradients generated in open jet wind tunnels. What has been lacking is whether this consistent result is independent of the other tunnel interference effects. The studies presented here are intended to fill that gap and add more realistic model and wind tunnel conditions to the evaluations of the performance of the two-measurement technique. The subject CFD studies are designed to greatly reduce all wind tunnel interference effects except for the variation of the non-linear static pressure gradients. A zero gradient condition is generated by simulating a solid wall test section with a blockage ratio of 0.1%.
X