Refine Your Search

Search Results

Viewing 1 to 4 of 4
Technical Paper

Injury Pattern and Tolerance of Human Pelvis Under Lateral Loading Simulating Car-pedestrian Impact

2003-03-03
2003-01-0165
Numerous studies of pelvic tolerance to lateral impact aimed at protecting car occupants have been conducted on Post Mortem Human Subjects (PMHSs) in a sitting posture. However, it remains unclear whether or not the results of these studies are relevant when evaluating the injury risk to walking pedestrians impacted by a car. Therefore, the first objective of the present study is to determine the injury tolerance and to describe the injury mechanisms of the human pelvis in lateral impacts simulating car-pedestrian accidents. The second objective is to obtain data for validation of mathematical models of the pelvis. In-vitro experiments were conducted on twelve PMHSs in simulated standing position. The trochanter of each PMHS was hit by a ram at speed of 32 km/h, and the pelvic motion was constrained by a bolt. This type of pelvic constraint is difficult to simulate in mathematical models.
Technical Paper

Injury Pattern and Response of Human Thigh under Lateral Loading Simulating Car-Pedestrian Impact

2004-03-08
2004-01-1603
The main objective of the present study is to determine experimentally the injury patterns and response of the human thigh in lateral impacts simulating more closely the real impact conditions in car-pedestrian accidents. We conducted in-vitro experiments on thirteen thighs of eight completely intact Post Mortem Human Subjects (PMHSs). The thigh was hit by a ram at a speed of 35 km/h at the mid-shaft of the femur in each completely intact PMHS. Since the effect of cumulative injuries should be avoided, each thigh was impacted only once. Three impact energies were used; 450J, 600J and 700J. The PMHS motion was not constrained so as to simulate the walking posture of a pedestrian. We analyzed the peak values of the impact force of the ram and the femur acceleration. Injury was assessed by dissecting the lower extremities.
Technical Paper

Comparison of Pedestrian Subsystem Safety Tests Using Impactors and Full-Scale Dummy Tests

2002-03-04
2002-01-1021
Evaluation of car front aggressiveness in car-pedestrian accidents is typically done using sub-system tests. Three such tests have been proposed by EEVC/WG17: 1) the legform to bumper test, 2) the upper legform to bonnet leading edge test, and 3) the headform to bonnet top test. These tests were developed to evaluate performance of the car structure at car to pedestrian impact speed of 11.1 m/s (40 km/h), and each of them has its own impactor, impact conditions and injury criteria. However, it has not been determined yet to what extent the EEVC sub-system tests represent real-world pedestrian accidents. Therefore, there are two objectives of this study. First, to clarify the differences between the injury-related responses of full-scale pedestrian dummy and results of sub-system tests obtained under impact conditions simulating car-to-pedestrian accidents. Second, to propose modifications of current sub-system test methods. In the present study, the Polar (Honda R&D) dummy was used.
Technical Paper

A new legform impactor for evaluation of car aggressiveness in car-pedestrian accidents

2001-06-04
2001-06-0174
The goal of the present study was to develop a new legform impactor that accurately represents both the impact force (i.e., force between the leg and impacting mass)and leg kinematics in lateral impacts simulating car-pedestrian accidents. In its development we utilized the knee joint of the pedestrian dummy called Polar-2 (HONDA R&D) in which the cruciate and collateral ligaments are represented by means of springs and cables, the geometry of the femoral condyles is simplified using ellipsoidal surfaces, and the tibial meniscus is represented by an elastomeric pad. The impactor was evaluated by comparing its responses with published experimental results obtained using postmortem human subjects (PMHS). The evaluation was done under two conditions: 1)impact point near the ankle area (bending tests),and 2)impact point 84 mm below the knee joint center (shearing tests). Two impact speeds were used: 5.56 m/s and 11.11 m/s.