Refine Your Search

Search Results

Viewing 1 to 10 of 10
Technical Paper

Thermal Engineering of Mars Entry Carbon/Carbon Non-Ablative Aeroshell - Part 2

2000-07-10
2000-01-2404
Candidate Aeroshell Test models composed of a quasi-isotropic Carbon/Carbon(C/C) front face sheet (F/S), eggcrate core, C/C back F/S, Carbon Aerogel insulation, C/C radiation shield and the C/C close-out were constructed based on the analytical temperature predictions presented in Part One of this work[1]. The analytical results obtained for a simulated Mars entry of a 2.9 meter diameter cone shaped Carbon-Carbon Aeroshell demonstrated the feasibility of the design. These results showed that the maximum temperature the front F/S reached during the decent was 1752 °C with the resulting rear temperature reaching 326 °C in the thermal model. Part Two of this work documents the thermal modeling and correlation for the Mars Aeroshell test sample and fixture. A finite difference, SINDA/G, thermal math model of the test fixture and sample was generated and correlated to data from an arc jet test conducted at the NASA Ames Research Center's interactive heating facility.
Technical Paper

Thermal Design and Flight Experience of the Mars Exploration Rover Spacecraft Computer-Controlled, Propulsion Line Heaters

2004-07-19
2004-01-2412
As part of the Mars Exploration Rover (MER) project, the National Aeronautics and Space Administration (NASA) launched two rovers in June and July of 2003 and successfully landed both of them on Mars in January of 2004. The cruise stage of each spacecraft (S/C) housed most of the hardware needed to complete the cruise from Earth to Mars, including the propulsion system. Propulsion lines brought hydrazine propellant from tanks under the cruise stage to attitude-control thrusters located on the periphery of the cruise stage. Hydrazine will freeze in the propellant lines if it reaches temperatures below 1.7°C. Thermal control of the propulsion lines was a mission critical function of the thermal subsystem; a frozen propellant line could have resulted in loss of attitude control and complete loss of the S/C.
Journal Article

Thermal Design Trade Study for the Mars Science Laboratory ChemCam Body Unit

2009-07-12
2009-01-2462
The Mars Science Laboratory will be the next Martian mobility system that is scheduled to launch in the fall of 2011. The ChemCam Instrument is a part of the MSL science payload suite. It is innovative for planetary exploration in using a technique referred to as laser breakdown spectroscopy to determine the chemical composition of samples from distances of up to about 9 meters away. ChemCam is led by a team at the Los Alamos National Laboratory and the Centre d'Etude Spatiale des Rayonnements in Toulouse, France. The portion of ChemCam that is located inside the Rover, the ChemCam Body Unit contains the imaging charged-coupled device (CCD) detectors. Late in the design cycle, the ChemCam team explored alternate thermal design architectures to provide CCD operational overlap with the Rover's remote sensing instruments. This operational synergy is necessary to enable planning for subsequent laser firings and geological context.
Technical Paper

The Mars Thermal Environment and Radiator Characterization (MTERC) Experiment

2000-07-10
2000-01-2402
Radiators will be used on Mars to reject excess heat from various processes and surfaces and will help temper the climate of any future manned habitats. Radiator performance is a function of the radiator size (area), the emissivity, ε, of the radiator surface, the radiator temperature, local environmental conditions, and the effective sky temperature to which it radiates. The effective sky temperature of Mars is not known. Previous estimates have ranged between 80 K to 170 K. Also, it is not known how dust accumulation and other environmental effects act to change the performance of a radiator as a function of time. The MTERC Experiment is designed to gather data to address these unknowns. This paper will describe the operational theory and the configuration of the MTERC experiment hardware and will discuss results of MTERC performance testing.
Technical Paper

Sorbent Bed Acquisition and Compression of Carbon Dioxide from the Mars Atmosphere

2000-07-10
2000-01-2237
Human exploration of Mars as well as unmanned sample return missions from Mars can benefit greatly from the use of propellants produced from the resources available from the atmosphere of Mars. The first major step of any in-situ propellant production (ISPP) system is to acquire carbon dioxide (CO2) from the Mars atmosphere and compress it for further chemical processing. One system that performs this step is called a Mars Atmosphere Acquisition and Compression (MAAC) unit. A simple prototype MAAC was developed by JPL as part of the Mars ISPP Precursor (MIP) experiment package for inclusion on the Mars 2001 Surveyor Lander. The MAAC consists of a valved enclosure packed with a sorbent material which selectively adsorbs CO2 from the Mars atmosphere (valves open), desorbs and compresses the acquired CO2 by heating (valves closed) and then delivers the pressurized CO2 to an oxygen generating system where the CO2 is electrolyzed to produce oxygen.
Technical Paper

Sojourner Mars Rover Thermal Performance

1998-07-13
981685
The Sojourner Rover landed on the surface of Mars on July 4, 1997 as part of the Mars Pathfinder Mission. The mission lasted almost three months during which the thermal design of the Rover was tested. This paper summarizes the Rover's design and performance as well as post-mission model correlation.
Technical Paper

Mars Exploration Rover Thermal Test Program Overview

2004-07-19
2004-01-2310
In January 2004, two Mars Exploration Rovers (MER) landed on the surface of Mars to begin their mission as robotic geologists. A year prior to these historic landings, both rovers and the spacecraft that delivered them to Mars, were completing a series of environmental tests in facilities at the Jet Propulsion Laboratory. This paper describes the test program undertaken to validate the thermal design and verify the workmanship integrity of both rovers and the spacecraft. The spacecraft, which contained the rover within the aeroshell, were tested in a 7.5 m diameter thermal vacuum chamber. Thermal balance was performed for the near earth (hot case) condition and for the near Mars (cold case) condition. A solar simulator was used to provide the solar boundary condition on the solar array. IR lamps were used to simulate the solar heat load on the aeroshell for the off-sun attitudes experienced by the spacecraft during its cruise to Mars.
Journal Article

Ground Validation of the Third Generation JPL Electronic Nose

2008-06-29
2008-01-2044
The Third Generation ENose is an air quality monitor designed to operate in the environment of the US Lab on the International Space Station. It detects a selected group of analytes at target concentrations in the ppm regime at an environmental temperature range of 18 - 30 °C, relative humidity from 25 - 75% and pressure from 530 to 760 torr. The abilities of the device to detect ten analytes, to reject confounders as “unknown” and to deconvolute mixtures of two analytes under varying environmental conditions has been tested extensively in the laboratory. Results of ground testing showed an overall success rate for detection, identification and quantification of analytes of 87% under nominal temperature and humidity conditions and 83% over all conditions.
Technical Paper

Capillary Limit in a Loop Heat Pipe with Dual Evaporators

2002-07-15
2002-01-2503
This paper describes a study on the capillary limit of a loop heat pipe (LHP) with two evaporators and two condensers. Both theoretical analysis and experimental investigation are performed. Experimental tests conducted include heat load to one evaporator only, even heat loads to both evaporators, and uneven heat loads to both evaporators. Test results show that after the capillary limit is exceeded, vapor will penetrate through the wick of the weaker evaporator, and the compensation chamber (CC) of that evaporator will control the loop operating temperature regardless of which CC has been in control prior to the event. Because the evaporator can tolerate vapor bubbles, the loop can continue to work after vapor penetration. As the loop operating temperature increases, the system pressure drop actually decreases due to a decrease in liquid and vapor viscosities. Thus, the loop may reach a new steady state at a higher operating temperature after vapor penetration.
X