Refine Your Search

Search Results

Viewing 1 to 4 of 4
Journal Article

Removal of EGR Cooler Deposit Material by Flow-Induced Shear

2013-04-08
2013-01-1292
A number of studies have identified a tendency for exhaust gas recirculation (EGR) coolers to foul to a steady-state level and subsequently not degrade further. One possible explanation for this behavior is that the shear force imposed by the gas velocity increases as the deposit thickens. If the shear force reaches a critical level, it achieves a removal of the deposit material that can balance the rate of deposition of new material, creating a stabilized condition. This study reports efforts to observe removal of deposit material in-situ during fouling studies as well as an ex-situ removal through the use of controlled air flows. The critical gas velocity and shear stress necessary to cause removal of deposit material is identified and reported. In-situ observations failed to show convincing evidence of a removal of deposit material. The results show that removal of deposit material requires a relatively high velocity of 40 m/s or higher to cause removal.
Technical Paper

Impact of Fuel Metal Impurities on the Durability of a Light-Duty Diesel Aftertreatment System

2013-04-08
2013-01-0513
Alkali and alkaline earth metal impurities found in diesel fuels are potential poisons for diesel exhaust catalysts. Using an accelerated aging procedure, a set of production exhaust systems from a 2011 Ford F250 equipped with a 6.7L diesel engine have been aged to an equivalent of 150,000 miles of thermal aging and metal exposure. These exhaust systems included a diesel oxidation catalyst (DOC), selective catalytic reduction (SCR) catalyst, and diesel particulate filter (DPF). Four separate exhaust systems were aged, each with a different fuel: ULSD containing no measureable metals, B20 containing sodium, B20 containing potassium and B20 containing calcium. Metals levels were selected to simulate the maximum allowable levels in B100 according to the ASTM D6751 standard. Analysis of the aged catalysts included Federal Test Procedure emissions testing with the systems installed on a Ford F250 pickup, bench flow reactor testing of catalyst cores, and electron probe microanalysis (EPMA).
Technical Paper

Direct Measurement of EGR Cooler Deposit Thermal Properties for Improved Understanding of Cooler Fouling

2009-04-20
2009-01-1461
Exhaust gas recirculation (EGR) cooler fouling has become a significant issue for compliance with NOx emissions standards. This paper reports results of a study of fundamental aspects of EGR cooler fouling. An apparatus and procedure were developed to allow surrogate EGR cooler tubes to be exposed to diesel engine exhaust under controlled conditions. The resulting fouled tubes were removed and analyzed. Volatile and non-volatile deposit mass was measured for each tube. Thermal diffusivity of the deposited soot cake was measured by milling a window into the tube and using the Xenon flash lamp method. The heat capacity of the deposit was measured at temperatures up to 430°C and was slightly higher than graphite, presumably due to the presence of hydrocarbons. These measurements were combined to allow calculation of the deposit thermal conductivity, which was determined to be 0.041 W/mK, only ∼1.5 times that of air and much lower than the 304 stainless steel tube (14.7 W/mK).
Journal Article

Characterization of Field-Aged EGR Cooler Deposits

2010-10-25
2010-01-2091
Exhaust gas recirculation (EGR) cooler fouling has become a significant issue for compliance with nitrogen oxides (NOx) emissions standards. In order to better understand fouling mechanisms, eleven field-aged EGR coolers provided by seven different engine manufacturers were characterized using a suite of techniques. Microstructures were characterized using scanning electron microscopy (SEM) and optical microscopy following mounting the samples in epoxy and polishing. Optical microscopy was able to discern the location of hydrocarbons in the polished cross-sections. Chemical compositions were measured using thermal gravimetric analysis (TGA), differential thermal analysis (DTA), gas chromatography-mass spectrometry (GC-MS), x-ray photoelectron spectroscopy (XPS), energy dispersive spectroscopy (EDS) and x-ray diffraction (XRD). Mass per unit area along the length of the coolers was also measured.
X