Refine Your Search

Topic

Author

Search Results

Technical Paper

Whole-body Response for Pedestrian Impact with a Generic Sedan Buck

2015-11-09
2015-22-0016
To serve as tools for assessing injury risk, the biofidelity of whole-body pedestrian impact dummies should be validated against reference data from full-scale pedestrian impact tests. To facilitate such evaluations, a simplified generic vehicle-buck has been recently developed that is designed to have characteristics representative of a generic small sedan. Three 40 km/h pedestrian-impact tests have been performed, wherein Post Mortem Human Surrogates (PMHS) were struck laterally in a mid-gait stance by the buck. Corridors for select trajectory measures derived from these tests have been published previously. The goal of this study is to act as a companion dataset to that study, describing the head velocities, body region accelerations (head, spine, pelvis, lower extremities), angular velocities, and buck interaction forces, and injuries observed during those tests.
Technical Paper

Whole-Body Response to Pure Lateral Impact

2010-11-03
2010-22-0014
The objective of the current study was to provide a comprehensive characterization of human biomechanical response to whole-body, lateral impact. Three approximately 50th-percentile adult male PMHS were subjected to right-side pure lateral impacts at 4.3 ± 0.1 m/s using a rigid wall mounted to a rail-mounted sled. Each subject was positioned on a rigid seat and held stationary by a system of tethers until immediately prior to being impacted by the moving wall with 100 mm pelvic offset. Displacement data were obtained using an optoelectronic stereophotogrammetric system that was used to track the 3D motions of the impacting wall sled; seat sled, and reflective targets secured to the head, spine, extremities, ribcage, and shoulder complex of each subject. Kinematic data were also recorded using 3-axis accelerometer cubes secured to the head, pelvis, and spine at the levels of T1, T6, T11, and L3. Chest deformation in the transverse plane was recorded using a single chestband.
Technical Paper

Thoracic Response of Belted PMHS, the Hybrid III, and the THOR-NT Mid-Sized Male Surrogates in Low-Speed, Frontal Crashes

2006-11-06
2006-22-0009
Injury to the thorax is the predominant cause of fatalities in crash-involved automobile occupants over the age of 65, and many elderly-occupant automobile fatalities occur in crashes below compliance or consumer information test speeds. As the average age of the automotive population increases, thoracic injury prevention in lower severity crashes will play an increasingly important role in automobile safety. This study presents the results of a series of sled tests to investigate the thoracic deformation, kinematic, and injury responses of belted post-mortem human surrogates (PMHS, average age 44 years) and frontal anthropomorphic test devices (ATDs) in low-speed frontal crashes. Nine 29 km/h (three PMHS, three Hybrid III 50th% male ATD, three THOR-NT ATD) and three 38 km/h (one PMHS, two Hybrid III) frontal sled tests were performed to simulate an occupant seated in the right front passenger seat of a mid-sized sedan restrained with a standard (not force-limited) 3-point seatbelt.
Technical Paper

The Tolerance of the Femoral Shaft in Combined Axial Compression and Bending Loading

2009-11-02
2009-22-0010
The likelihood of a front seat occupant sustaining a femoral shaft fracture in a frontal crash has traditionally been assessed by an injury criterion relying solely on the axial force in the femur. However, recently published analyses of real-world data indicate that femoral shaft fracture occurs at axial loads levels below those found experimentally. One hypothesis attempting to explain this discrepancy suggests that femoral shaft fracture tends to occur as a result of combined axial compression and applied bending. The current study aims to evaluate this hypothesis by investigating how these two loading components interact. Femoral shafts harvested from human cadavers were loaded to failure in axial compression, sagittal plane bending, and combined axial compression and sagittal plane bending.
Technical Paper

The Flow Field Inside an Automotive Torque Converter: Laser Velocimeter Measurements

1996-02-01
960721
The 3-D flow field inside an automotive torque converter was measured using laser velocimetry. For the tests, a torque converter completely machined from Plexiglas was operated at the 0.065 and 0.800 turbine/pump speed ratio, and detailed velocities were measured in 13 planes throughout the torque converter. Digital shaft encoder information was used to correlate measured velocities with the pump/turbine angular positions to generate blade-to-blade profiles, 3-D vector plots, and contour through flow plots. Results showed large flow separation regions, jet/wake flows, circulatory secondary flows, and significant flow unsteadiness in all three torque converter elements (pump, turbine, and stator). From the measured velocities, torque converter performance parameters such as mass flows, input/output torque, element incidence angles, slip factors, and vorticities were determined.
Technical Paper

The Effect of Thermal Cycling on the Mechanical Properties of the Macro-Interface in Squeeze Cast Composites

1994-03-01
940810
Selectively reinforced, squeeze cast automotive pistons contain a boundary between the reinforced and unreinforced regions. This boundary is known as the macro-interface. Due to the difference in CTE between the composite and unreinforced matrix, the macro-interface can be the site of residual stress formation during cooling from the casting or heat treatment temperature. Subsequent thermal exposure, particularly thermal cycling, may produce cyclic stress at this interface causing it to experience fatigue. It has been found that matrix precipitates at the macro-interface and the aging behavior of the matrix also may play a role in defining the strength of the macro-interface during thermal cycling conditions.
Technical Paper

The Development, Validation and Application of a Finite Element Upper Extremity Model Subjected to Air Bag Loading

2003-10-27
2003-22-0004
Both frontal and side air bags can inflict injuries to the upper extremities in cases where the limb is close to the air bag module at the time of impact. Current dummy limbs show qualitatively correct kinematics under air bag loading, but they lack biofidelity in long bone bending and fracture. Thus, an effective research tool is needed to investigate the injury mechanisms involved in air bag loading and to judge the improvements of new air bag designs. The objective of this study is to create an efficient numerical model that exhibits both correct global kinematics as well as localized tissue deformation and initiation of fracture under various impact conditions. The development of the model includes the creation of a sufficiently accurate finite element mesh, the adaptation of material properties from literature into constitutive models and the definition of kinematic constraints at articular joint locations.
Technical Paper

The Contribution of Pre-impact Spine Posture on Human Body Model Response in Whole-body Side Impact

2014-11-10
2014-22-0014
The objective of the study was to analyze independently the contribution of pre-impact spine posture on impact response by subjecting a finite element human body model (HBM) to whole-body, lateral impacts. Seven postured models were created from the original HBM: one matching the standard driving posture and six matching pre-impact posture measured for each of six subjects tested in previously published experiments. The same measurements as those obtained during the experiments were calculated from the simulations, and biofidelity metrics based on signals correlation were established to compare the response of HBM to that of the cadavers. HBM responses showed good correlation with the subject response for the reaction forces, the rib strain (correlation score=0.8) and the overall kinematics. The pre-impact posture was found to greatly alter the reaction forces, deflections and the strain time histories mainly in terms of time delay.
Technical Paper

Structural and Material Changes in the Aging Thorax and Their Role in Crash Protection for Older Occupants

2005-11-09
2005-22-0011
The human body undergoes a variety of changes as it ages through adulthood. These include both morphological (structural) changes (e.g., increased thoracic kyphosis) and material changes (e.g., osteoporosis). The purpose of this study is to evaluate structural changes that occur in the aging bony thorax and to assess the importance of these changes relative to the well-established material changes. The study involved two primary components. First, full-thorax computed tomography (CT) scans of 161 patients, age 18 to 89 years, were analyzed to quantify the angle of the ribs in the sagittal plane. A significant association between the angle of the ribs and age was identified, with the ribs becoming more perpendicular to the spine as age increased (0.08 degrees/year, p=0.012). Next, a finite element model of the thorax was used to evaluate the importance of this rib angle change relative to other factors associated with aging.
Technical Paper

Structural Response of Cadaveric Ribcages Under a Localized Loading: Stiffness and Kinematic Trends

2010-11-03
2010-22-0015
To improve understanding of structural coupling and deformation patterns throughout the loaded ribcage, the present study reports the force-displacement and kinematic responses under a highly localized loading condition using three PMHS ribcages (ages 44, 61, and 63 years). The ribcages were quasi-statically loaded locally to a non-failure displacement (nominally 15% of the ribcage depth at the loaded rib level) at approximately 25 unilateral locations and 5-7 geometrically symmetric bilateral locations on the anterior surface of each ribcage, for a total of 94 tests. The translations of 56 points distributed around the anterior, lateral, and posterior portions of the superficial surface of the ribcage were measured while under loading. Each of the first through sixth rib levels was then separated from the remaining ribs, and this "rib ring" structure was individually loaded at the sternum in the anterior-posterior direction.
Technical Paper

Rollover Initiation Simulations for Designing Rollover Initiation Test System (RITS)

2014-04-01
2014-01-0530
Some rollover test methods, which impose a touchdown condition on a test vehicle, have been developed to study vehicle crashworthiness and occupant protection in rollover crashes. In ground-tripped rollover crashes, speed, steering maneuver, braking, vehicle inertial and geometric properties, topographical and road design characteristics, and soil type can all affect vehicle touchdown conditions. It is presumed that while there may be numerous possible combinations of kinematic metrics (velocity components and orientation) at touchdown, there are also numerous combinations of metrics that are not likely to occur in rollover crashes. To determine a realistic set of touchdown conditions to be used in a vehicle rollover crash test, a lateral deceleration sled-based non-destructive rollover initiation test system (RITS) with a fully programmable deceleration pulse is in development.
Technical Paper

Reducing the Risk of Driver Injury from Common Steering Control Devices in Frontal Collisions

1999-03-01
1999-01-0759
Steering control devices are used by people who have difficulty gripping the steering wheel. These devices have projections that may extend up to 14 cm toward the occupant. Testing indicated that contact with certain larger steering control devices with tall rigid projections could severely injure a driver in a frontal collision. In order to reduce this injury risk, an alternative, less injurious design was developed and tested. This design, which included replacing unyielding aluminum projections with compliant plastic ones, produced significantly lower peak contact pressure and less damage to the chest of a cadaver test subject, while maintaining the strength necessary to be useful.
Technical Paper

Recreational Off-Highway Vehicle Safety: Countermeasures for Ejection Mitigation in Rollover

2016-04-05
2016-01-1513
Recreational Off-Highway Vehicles (ROVs), since their introduction onto the market in the late-1990s, have been related to over 300 fatalities with the majority occurring in vehicle rollover. In recent years several organizations made attempts to improve ROV safety. This paper is intended to evaluate ejection mitigation measures considered by the ROV manufacturers. Evaluated countermeasures include two types of occupant restraints (three and four point) and two structural barriers (torso bar, door with net). The Rollover protection structure (ROPS) provided by the manufacturer was attached to a Dynamic Rollover Test System (DRoTS), and a full factorial series of roll/drop/catch tests was performed. The ROV buck was equipped with two Hybrid III dummies, a 5th percentile female and a 95th percentile male. Additionally, occupant and vehicle kinematics were recorded using optoelectronic stereophotogrammetric camera system.
Technical Paper

Rear Seat Occupant Safety: Kinematics and Injury of PMHS Restrained by a Standard 3-Point Belt in Frontal Crashes

2008-11-03
2008-22-0012
Very little experimental research has focused on the kinematics, dynamics, and injuries of rear-seated occupants. This study seeks to develop a baseline response for rear-seated post mortem human surrogates (PMHS) in frontal crashes. Three PMHS sled tests were performed in a sled buck designed to represent the interior rear-seat compartment of a contemporary midsized sedan. All occupants were positioned in the right-rear passenger seat and subjected to simulated frontal crashes with an impact speed of 48 km/h. The subjects were restrained by a standard, rear seat, 3-point seat belt. The response of each subject was evaluated in terms of whole-body kinematics, dynamics, and injury. All the PMHS experienced excessive forward translation of the pelvis resulting in a backward rotation of the torso at the time of maximum forward excursion.
Technical Paper

Rear Seat Occupant Safety: An Investigation of a Progressive Force-Limiting, Pretensioning 3-Point Belt System Using Adult PMHS in Frontal Sled Tests

2009-11-02
2009-22-0002
Rear seat adult occupant protection is receiving increased attention from the automotive safety community. Recent anthropomorphic test device (ATD) studies have suggested that it may be possible to improve kinematics and reduce injuries to rear seat occupants in frontal collisions by incorporating shoulder-belt force-limiting and pretensioning (FL+PT) technologies into rear seat 3-point belt restraints. This study seeks to further investigate the feasibility and potential kinematic benefits of a FL+PT rear seat, 3-point belt restraint system in a series of 48 kmh frontal impact sled tests (20 g, 80 ms sled acceleration pulse) performed with post mortem human surrogates (PMHS). Three PMHS were tested with a 3-point belt restraint with a progressive (two-stage) force limiting and pretensioning retractor in a sled buck representing the rear seat occupant environment of a 2004 mid-sized sedan.
Technical Paper

Pediatric Thoracoabdominal Biomechanics

2009-11-02
2009-22-0013
No experimental data exist quantifying the force-deformation behavior of the pediatric chest when subjected to non-impact, dynamic loading from a diagonal belt or a distributed loading surface. Kent et al., (2006) previously published juvenile abdominal response data collected using a porcine model. This paper reports on a series of experiments on a 7-year-old pediatric post-mortem human subject (PMHS) undertaken to guide the scaling of existing adult thoracic response data for application to the child and to assess the validity of the porcine abdominal model. The pediatric PMHS exhibited abdominal response similar to the swine, including the degree of rate sensitivity. The upper abdomen of the PMHS was slightly stiffer than the porcine behavior, while the lower abdomen of the PMHS fit within the porcine corridor. Scaling of adult thoracic response data using any of four published techniques did not successfully predict the pediatric behavior.
Technical Paper

Patterns of Acetabular Femoral Head Coverage

2011-11-07
2011-22-0018
The size and shape of the acetabulum and of the femoral head influence the injury tolerance of the hip joint. The aim of this study is to quantify changes in acetabular cup geometry that occur with age, gender, height, and weight. Anonymized computed tomography (CT) scans of 1,150 individuals 16+ years of age, both with and without hip trauma, were used to describe the acetabular rim with 100 equally spaced points. Bilateral measurements were taken on uninjured patients, while only the uninjured side was valuated in those with hip trauma. Multinomial logistic regression found that after controlling for age, height, weight, and gender, each 1 degree decrease in acetabular anteversion angle (AAA) corresponded to an 8 percent increase in fracture likelihood (p≺0.001).
Technical Paper

Open-Loop Chestbands for Dynamic Deformation Measurements

1998-02-23
980857
Originally designed for measuring closed-loop contours such as those around a human thorax, the External Peripheral Instrument for Deformation Measurement (EPIDM), or chestband, was developed to improve the measurement of dummy and cadaver thoracic response during impact. In the closed-loop configuration, the chestband wraps around on itself forming a closed contour. This study investigates the use of the chestband for dynamic deformation measurements in an open-loop configuration. In the open-loop configuration, the chestband does not generally form a closed contour. This work includes enhanced procedures and algorithms for the calculation of chestband deformation contours including the determination of static and dynamic chestband contours under several boundary conditions.
Technical Paper

On the Importance of Nonlinearity of Brain Tissue Under Large Deformations

2003-10-27
2003-22-0005
Linear shear properties of human and bovine brain tissue were determined from transient stress-relaxation experiments and their material functions were compared. Quasi-linear viscoelastic theory was then utilized to determine material constants for bovine brain tissue subjected to large deformations. The range of applicability for linear and quasi-linear constitutive models of brain tissue was determined. A nonlinear Green-Rivlin constitutive model was subsequently applied to characterize temporal nonlinearity of bovine brain tissue in shear. Overall, 10 brain specimens from 5 fresh human cadavers and 156 brain specimens from 26 fresh bovine cadaver brains were used to quantify and compare shear brain responses under various loading conditions. The assumptions of homogeneity, isotropy, and incompressibility of brain material were made in order to reduce the required number of experiments.
Technical Paper

Occupant Kinematics in Laboratory Rollover Tests: ATD Response and Biofidelity

2014-11-10
2014-22-0012
Rollover crashes are a serious public health problem in United States, with one third of traffic fatalities occurring in crashes where rollover occurred. While it has been shown that occupant kinematics affect the injury risk in rollover crashes, no anthropomorphic test device (ATD) has yet demonstrated kinematic biofidelity in rollover crashes. Therefore, the primary goal of this study was to assess the kinematic response biofidelity of six ATDs (Hybrid III, Hybrid III Pedestrian, Hybrid III with Pedestrian Pelvis, WorldSID, Polar II and THOR) by comparing them to post mortem human surrogate (PMHS) kinematic response targets published concurrently; and the secondary goal was to evaluate and compare the kinematic response differences among these ATDs.