Refine Your Search

Search Results

Viewing 1 to 7 of 7
Technical Paper

Vacuum Cleaning Vehicle Dust Subsidence System Design

2014-04-01
2014-01-0750
Vacuum cleaning vehicle is the necessary equipment for the Municipal Sanitation Department to keep the road surface clean and the dust subsidence system is the heart unit for the proper function of the cleaning vehicle. The reasonable design of this system could increase the load capacity of the vehicle and be convenient for the garbage collecting and dumping. Meanwhile, the engine power could be relatively reduced and the influence on the environment duo to the dusty air in the outlet could be also effectively improved. In the study, the gravity dedusting principle is used firstly for structure design to reduce the flow rate of dust particles inside the lower part of the dust subsidence system. The ruleless collision loss among dust particles is reduced and thereby the fan power is saved. By means of a reasonable separated chamber design and the use of inertia baffle, the sort management for dust particles is developed and the work stress of the export filter is released observably.
Technical Paper

Thermoelectric Module Temperature Stability Control for the Vehicle Engine Exhaust Heat Recovery

2015-04-14
2015-01-0350
The vehicle engine exhaust wastes heat. For the conventional scheme, the hot-end of the thermoelectric module is connected with the exhaust pipe, while the cold-end is cooled through the vehicle engine cooling cycle. The variation of vehicle engine operating conditions brings the instability of the hot-end temperature, which affects the power generation performance of thermoelectric materials and increases the damage risk to the thermoelectric materials caused by the high temperature. This research adopts the heat transfer oil circulation as the intermediate fluid to absorb the dynamic heat flux of the vehicle engine exhaust so as to release the heat steadily to the hot-end of the thermoelectric module. The thermal characteristics of the target diesel vehicle engine exhaust gas are evaluated based on the experimental data firstly.
Technical Paper

The Research of Solar Organic Rankine Evaporation Cycle System for Vehicle

2016-04-05
2016-01-1268
With the help of organic working medium absorbing the solar energy for steam electric power generation, green energy can be provided to automotive accessories so as to improve the vehicle energy efficiency. In the hot summer, the exhausted heat resulting from cars’ directly exposing to the sun can be used to cool and ventilate the passenger compartment. Considering the space occupied by the system in the combination of both practical features for solar heat source--low power and poor stability-- a compact evaporation structure was designed to enhance the solar utilization efficiency. In the research, the heat source of power and temperature variation range was determined by the available solar roof with photo-thermal conversion model. Then started from the ratio of exhausted heat utilization corresponding to evaporator’s characteristic parameter, the performance analysis was made in the different working conditions.
Technical Paper

Solar Powered Vehicle Parking Ventilation System Pre-Cooling Analysis

2015-04-14
2015-01-0367
The cabin air temperature increases quickly and can reach 80°C when the vehicle parks in the summer sunlight which has the bad influence on the occupants entering comfort. Some luxury vehicles, like Audi A8[1], reduce the internal temperature through operating air-condition in advance or using on-board battery to drive the cabin ventilator, which requires relatively complex control system and limits the system's operating time because of energy consumption. This research adopts the solar wing as the ventilation power supply and accomplishes the cabin real-time heat rejection by achieving the steady air circulation for both inside and outside environment. First, the static thermal transfer model of the crew cabin is established. Then, on the basis of the parameters of the prototype ventilation pipe, the ventilation model for the outside circulation is built.
Technical Paper

SUV Solar Roof with Photo-Thermal Effect for Ventilation ORC System

2016-04-05
2016-01-0240
The Organic Rankine Cycle System (ORC) is an effective means to use the solar energy. The system adopts the solar energy on the car roof as the heat source to make the ORC work and drive the thermoelectric air-conditioner. It can improve the entering comfort on the parking condition and the vehicle energy utilization efficiency. In this research, the system comprehensively applied the principle of sunshine concentration, heat collection and photo electricity. Then considering the working condition and performance features of ORC system, the car roof was designed to have a compact structure, through which the efficiency of the solar vehicle system could be improved. Firstly, the research analyzed the heat source temperature and the heat flux impact on the output power of the ORC system. After that, the performance of heat collection was identified according to the given thermoelectric air-condition’s power requirements.
Technical Paper

Microwave-Steam Based Road Deicing Vehicle Focused on Thin Ice Layers

2015-04-14
2015-01-0502
For the thin ice on the road in winter, the traditional road deicing vehicle relies on mechanical and chemical methods for melting ice, which is inclined to damage the pavement and has insidious influence on environment. The thermal deicing vehicle has been adopted in recent years. Although the deicing method is available, the deicing efficiency is unacceptable while the energy consumption is huge. The study adopts the new idea of “bottom-to-top” for melting the intersection area between the road surface and the bottom ice layer by the microwave heating firstly and then cleaning them out using high pres. vapor cutting so as to save the cost of energy and enhance the traffic safety. First of all, the mathematical model of the melting process of the intersection of the pavement and the ice layer was established according to the microwave heating characteristics.
Technical Paper

Evaporator Boiling Heat Transfer Analysis for Engine Exhaust Heat Recovery

2014-09-30
2014-01-2345
In the Rankine cycle, the pressure differential generated by the phase change of the working fluid produces turbine output power, which enables the recovery of waste heat from the internal combustion engine. The heat transfer ability of the evaporator is the key factor that determines the quality of turbine's mechanical work. In this paper, the performance of the evaporator with two-phase zone and preheated zone is studied. After obtaining the thermal characteristics of diesel engine exhaust from the experimental data, the mathematical model of the evaporator is built according to the specific working conditions of ORC and geometrical parameters of the evaporator. Three typical engine operating conditions are used to estimate the heat transfer characteristics of the evaporator. The result shows that, in the evaporator, the heat transfer coefficient of the Rankine working fluid is much greater than the exhaust side of the engine.
X