Standard

Total Temperature Measuring Instruments (Turbine powered Subsonic Aircraft)

2008-02-16
CURRENT
AS793A
This standard covers three basic types of total-temperature-measuring instruments used as a means of determining the total temperature developed by adiabatic heating of the air due to motion of the aircraft through the air. Type I - Flush-type total-temperature sensor Type II - Probe-type total-temperature sensor (electrically heated) Type III - probe-type total-temperature sensor (unheated)
Standard

Temperature Instruments (Reciprocating Engine Powered Aircraft)

2008-02-16
CURRENT
AS413B
This Aerospace Standard covers two basic types of temperature instruments as follows: TYPE I: Ratiometer type, actuated by changes in electrical resistance of a temperature sensing electrical resistance element; the resistance changes being obtained by temperature changes of the temperature sensing resistance element. TYPE II: Millivoltmeter type, operated and actuated by varying E.M.F. output of a thermocouple; the varying E.M.F. input to the instrument being obtained by temperature changes of the temperature sensing thermocouple.
Standard

TURN AND BANK INDICATOR

1947-07-01
CURRENT
AS395
This specification covers three basic types of instruments as follows: TYPE I - Air Driven TYPE II - D-C Operated TYPE III - A-C Operated
Standard

TEMPERATURE INSTRUMENTS (TURBINE POWERED SUBSONIC AIRCRAFT)

2008-02-16
CURRENT
AS414B
This SAE Aerospace Standard (AS) covers two basic types of temperature instruments as follows: Type I: Ratiometer type, actuated by changes in electrical resistance of a temperature sensing electrical resistance element; the resistance changes being obtained by temperature changes of the temperature sensing resistance element. Type II: Millivoltmeter type, operated and actuated by varying EMF output of a thermocouple; the varying EMF input to the instrument being obtained by temperature changes of the temperature sensing thermocouple.
Standard

TEMPERATURE INDICATOR

1954-12-01
HISTORICAL
AS413A
This Aeronautical Standard covers two basic types of temperature indicators as follows: TYPE I - Ratiometer type actuated by changes of electrical resistance of a temperature sensing electrical resistance element; the resistance changes being obtained by temperature changes of the temperature sensing resistance element. TYPE II - Millivoltmeter type, operated and actuated by varying e.m.f. output of a thermocouple, the varying e.m.f. input to the instrument being obtained by temperature changes of the temperature sensing thermocouple.
Standard

TEMPERATURE INDICATOR

1948-11-01
HISTORICAL
AS413
This specification covers two types of instruments. These instruments are for the purpose of measuring temperature, such as those of oil coolant, carburetor air, free air and cylinder head.
Standard

Stall Warning Instrument (Turbine Powered Subsonic Aircraft)

2008-02-16
CURRENT
AS439A
This standard covers stall warning instruments to provide positive warning to the pilot of an impending stall. Stall, as defined for the purpose of this standard, is the minimum steady flight speed at which the airplane is controllable.
Standard

Single-Degree-of-Freedom Spring-Restrained Rate Gyros

2008-02-16
CURRENT
AS1104
This specification covers that gyroscopic instrument normally defined as a "subminiature rate gyro." The rate gyro, when subjected to an angular rate about its input axis, provides an AC output voltage proportional to the angular rate. The subminiature size category generally includes gyro instruments of one (1) inch diameter or less and three and one-half (3 1/2) inches length or less. This specification defines the requirements for a subminiature spring-restrained, single-degree-of-freedom rate gyro for aircraft, missile, and spacecraft applications.
Standard

STALL WARNING INSTRUMENT (Turbine Powered Subsonic Aircraft)

1991-05-01
HISTORICAL
AS439
This standard covers stall warning instruments to provide positive warning to the pilot of an impending stall. Stall, as defined for the purpose of this standard, is the minimum steady flight speed at which the airplane is controllable.
Standard

RATE OF CLIMB INDICATOR, PRESSURE ACTUATED (VERTICAL SPEED INDICATOR)

2008-02-16
CURRENT
AS394A
This Aeronautical Standard covers four (4) basic types of direct indicating instruments as follows: TYPE I - Range 0-2000 feet per minute climb and descent TYPE II - Range 0-3000 feet per minute climb and descent TYPE III - Range 0-4000 feet per minute climb and descent TYPE IV - Range 0-6000 feet per minute climb and descent
Standard

PRECISION MOTOR TACHOMETER GENERATOR

2008-02-16
CURRENT
ARP667
This recommended practice establishes objectives for high performance control motor tachometer generators to be used with aeronautical and associated equipment in protective enclosures or completely within the shell of the aircraft so that they are subjected only to the internal climatic conditions of heat, cold, shock, vibration, and humidity. Control motor tachometer generators larger than size 23 are not covered in this document.