This document provides guidance for applying aircraft equipment electromagnetic, electrical, and mechanical qualification standards (i.e., DO-160, MIL-STD-461, MIL-STD-704, and MIL-STD-810) to civil aircraft certification intended for military use and for military aircraft equipment installed on civil aircraft. The guidance identifies where the equipment environmental qualification standards meet the intent of both the civil or military aircraft certification requirements. Conversely, the guidance will identify where the equipment environmental qualification standards have differences that do not meet the intent of the civil or military aircraft certification requirements and when these differences matter based on equipment criticality, installation location, and/or other variables.
Engine charging of aircraft has been observed for many years. This SAE Aerospace Information Report (AIR) reviews the history of observations, physical characteristics, and possible techniques for minimizing the effects.
This Aerospace Recommended Practice (ARP) describes a standard method and means for measuring or calibrating the "Spectrum Amplitude" output of an impulse generator.
This Aerospace Recommended Practice (ARP) describes a standard method and means for measuring or calibrating the "Spectrum Amplitude" output of an impulse generator.
This SAE Aerospace Recommended Practice (ARP) outlines a standard method for the checkout and calibration of electromagnetic interference measurement antennas. Its primary application is for use when measuring a source 1 m from the antenna in a shield room versus a source at a greater distance (far field). This is the typical distance used in performing military EMC testing. Thus, this is a method of calibration. Shield room characteristics are not considered. It does not address an unknown distributed source. Yet it is close to reality since it is based on another antenna that represents a distributed source. This document presents a technique to determine antenna factors for antennas used primarily in performing measurements in accordance with 2.1 and 2.2. The purpose of Revision B is to include the calibration of other antennas, such as small loop antennas that are also specified for use in these same references.
This SAE Aerospace Recommended Practice outlines a standardized and economical method for the checkout and calibration of electromagnetic interference measurement antennas. Its application is for use when measuring a source 1 m from the antenna in a shield room. This is the typical distance used in performing military EMC testing. The influence of the shield room on the measured field strength is not considered. This standard does not address the measurement of emissions from an unknown distributed source, yet it attempts to resemble reality by using another antenna, in the calibration method, that represents a distributed source. This document presents a technique to determine antenna factors for antennas used primarily in performing measurements in accordance with References 2.1 and 2.2. The purpose of Revision B was to include the calibration of other antennas, such as biconical, horn, monopole and small loop antennas that are also specified for use in these same references.
This SAE Aerospace Recommended Practice (ARP) outlines a standard method for the checkout and calibration of electromagnetic interference measurement antennas. Its primary application is for use when measuring a source 1 m from the antenna in a shield room versus a source at a greater distance (far field). This is the typical distance used in performing military EMC testing. Thus, this is a method of calibration. Shield room characteristics are not considered. It does not address an unknown distributed source. Yet it is close to reality since it is based on another antenna that represents a distributed source. This document presents a technique to determine antenna factors for antennas used primarily in performing measurements in accordance with 2.1 and 2.2. The purpose of Revision B is to include the calibration of other antennas, such as small loop antennas that are also specified for use in these same references.
This SAE Aerospace Recommended Practice (ARP) outlines a standard method for the checkout and calibration of electromagnetic interference measurement antennas. Its primary application is for use when measuring a source 1 m from the antenna in a shield room versus a source at a greater distance (far field). This is the typical distance used in performing military EMC testing. Thus, this is a method of calibration. Shield room characteristics are not considered. It does not address an unknown distributed source. Yet it is close to reality since it is based on another antenna that represents a distributed source. This document presents a technique to determine antenna factors for antennas used primarily in performing measurements in accordance with 2.1 and 2.2. The purpose of Revision B is to include the calibration of other antennas, such as small loop antennas that are also specified for use in these same references.
This document contains a "sample" Control Plan with explanations as to the intended content of various sections. It also can serve as a sample technical construction file as specified by the European EMC Directive.
This document contains a "sample" Control Plan with explanations as to the intended content of various sections. It also can serve as a sample technical construction file as specified by the European EMC Directive.
This Aerospace Information Report (AIR) is intended to provide information relating to the construction, calibration, and usage of parallel plate transmission lines in electromagnetic compatibility susceptibility testing.
The purpose of this procedure is to establish a technique for reliably and repeatedly measuring the RF shielding characteristics of EMI gasket materials and EMI gaskets against various joint surfaces. The procedure is also used to test the reliability of the gasketed joint combinations after being subjected to hostile environments.
The purpose of this procedure is to establish a technique for reliably and repeatedly measuring the RF shielding characteristics of EMI gasket materials and EMI gaskets against various joint surfaces. The procedure is also used to test the reliability of the gasketed joint combinations after being subjected to hostile environments.
This Aerospace Recommended Practice (ARP) describes the requirements of a special purpose 10 μF feed through capacitor to be used in series with the power line to an electrical or electronic device during EMI tests.