Refine Your Search

Topic

Search Results

Standard

WDM LAN Network Management And Control

2014-11-07
WIP
AS5659/3
This document describes network management and control facilities for the WDM LAN, within the SAE AS5659 WDM LAN specifications document family. Unlike like point-to-point solutions, networks require a control plane to allocate the shared network resources and a management plane which provides a disciplined approach to configuring and monitoring the network. Within a Wavelength Division Multiplexed (WDM) environment, management and control provides wavelength selection and routing for traffic that is processed. The extent of network management and control depends on the design of the network, and can range from hardwired wavelengths to dynamic wavelength allocation with damage recovery.
Standard

WDM LAN Access and Aggregation

2014-11-07
WIP
AS5659/2
This document describes the Client Adaptation Element (CAE), the set of functions that provides access and aggregation capability for the WDM LAN, within the SAE AS5659 WDM LAN specifications document family. In the WDM LAN, the CAE fits in between the Optical Backbone, which provides transmission of data over the transparent network, and the clients which the network serves. The complexity of the CAE depends on the types and number of clients.
Standard

Transparent Optical Backbone Network Specification

2014-11-07
WIP
AS5659/1
This document provides a specification for the WDM Optical Backbone Network (OBN) within the SAE AS5659 WDM LAN specifications document family. The specification applies to any optical network which uses Wavelength Division Multiplexing (WDM) in any optical media, and describes a transparent optical network that contains optical components (i.e. without Optical-to-Electrical conversion). The specification describes optical network elements (ONE) that perform optical transport, optical add/drop, optical amplification, optical routing, and optical switching functions. Performance limits are given for conforming optical signal interfaces and transfer functions for the ONEs, as well as architectures comprising combinations of them. This specification will enable network and systems engineers to design and use scalable and upgradable WDM based optical networks aboard mobile platforms.
Standard

Terminus, Fiber Optic, Harsh Environment, General Specification

2021-11-23
CURRENT
AS8438
This document provides details of test methods that should be taken into consideration when qualifying fiber optic termini to the product specifications (slash sheets). The product specifications (slash sheets) provide pass/fail criteria, optical and physical intermatability, and interoperability requirements for fiber optic termini in circular, rectangular, and modular type aerospace connectors.
Standard

Multi-Transmitter Bidirectional Fiber-Optic Data Bus for Distributed Aircraft Control Systems

2011-03-22
CURRENT
AS5370A
This specification applies to a communication protocol for networked control systems. The protocol provides peer-to-peer communication for networked control and is suitable for implementing both peer-to-peer and master-slave control strategies. This specification describes services for all seven protocol layers. In the layer 7 specification, it includes a description of the types of messages used by applications to exchange application and network management data.
Standard

Multi-Transmitter Bidirectional Fiber-Optic Data Bus for Distributed Aircraft Control Systems

2002-04-26
HISTORICAL
AS5370
This specification applies to a communication protocol for networked control systems. The protocol provides peer-to-peer communication for networked control and is suitable for implementing both peer-to-peer and master-slave control strategies. This specification describes services for all seven protocol layers. In the layer 7 specification, it includes a description of the types of messages used by applications to exchange application and network management data.
Standard

Inline Optical Power Monitoring, Network End-to-End Data Link Evaluation System

2019-10-02
CURRENT
AIR6552/1
This document establishes methods to obtain, store, and access data about the health of a fiber optic network using commercially available inline optical power monitoring sensors. This document is intended for: Managers Engineers Technicians Contracting officers Third party maintenance agencies Quality assurance
Standard

In-Service Fiber Optic Inspection, Evaluation, and Cleaning, Best Practices, Expanded Beam Termini

2020-03-18
CURRENT
ARP6283/1
This document provides user information on best practice methods and processes for the in-service inspection, evaluation, and cleaning of expanded beam (EB) fiber optic interconnect components (termini, alignment sleeves, and connectors), test equipment, and test leads based on the information provided in AIR6031 and ARP6283. This document provides the user with a decision-making tool to determine if the fiber optic components are acceptable for operation with EB fiber optic termini.
Standard

In-Service Fiber Optic Inspection, Evaluation and Cleaning, Best Practices, Physical Contact Termini

2018-01-04
CURRENT
ARP6283
This document provides recommended best practice methods and processes for the in-service inspection, evaluation and cleaning of all physical contact (PC) fiber optic interconnect components (termini, alignment sleeves and connectors), test equipment and test leads for maintainers qualified to the approved aerospace fiber optic training courses developed in accordance with ARP5602 or ARINC807. This document also provides a decision-making disposition flowchart to determine whether the fiber optic components are acceptable for operation. For definitions of individual component parts refer to ARP5061.
Standard

Fiber Optic Harsh Environment Test Methods Cross Reference Document

2021-06-10
CURRENT
AIR6282A
This report provides cross reference matrices detailing current test methods used in the qualification processes of fiber optic connectors, termini and cables for aerospace, telecommunications, and naval applications. The cross-reference allows the end user to select the test methods most suitable for qualifying a component, or to identify alternative test methods where a specific test is not defined in a referenced document. The report also provides information on what area each type of referenced document has been developed for.
Standard

Fiber Optic Cleaning

2018-01-23
CURRENT
AIR6031
This document is intended for connectors typically found on aerospace platforms and ground support equipment. The document provides the reasons for proper fiber optic cleaning, an in-depth discussion of available cleaning methods, materials, packaging, safety, and environmental concerns. Applicable personnel include: Managers Designers Engineers Technicians Trainers/Instructors Third Party Maintenance Agencies Quality Personnel Purchasing Shipping/Receiving Production
Standard

Digital Fiber Optic Link Loss Budget Methodology for Aerospace Platforms

2018-01-23
CURRENT
AS5603A
This document defines the steps and documentation required to perform a digital fiber optic link loss budget. This document does not specify how to design a digital fiber optic link. This document does not specify the parameters and data to use in a digital fiber optic link loss budget.
Standard

Connectors, Fiber Optic, Advanced, Circular, Modular or Rectangular, Plug and Receptacle, Harsh Environment, Removable Termini, General Specification for

2020-12-29
CURRENT
AS8050
The AS8050 master document contains general information for qualification of aerospace fiber optic, circular, modular, and rectangular connectors as part of a fiber optic interconnect assembly comprising of a connector, fiber optic cable, and fiber optic terminus. The product specifications (slash sheets) contain dimensional, mechanical, and operating performance requirements for aerospace fiber optic, circular, and rectangular connectors. The product specifications (slash sheets) reference associated aerospace fiber optic termini and cables suitable for use with AS8050 connectors.
X