Refine Your Search

Topic

Search Results

Standard

Vehicle Electromagnetic Radiated Susceptibility Testing Using a LargeTEM Cell

1995-07-01
CURRENT
J1407_199507
This information report gives the procedures for use and operation of a large transverse electromagnetic (TEM) mode cell for the determination of electromagnetic (EM) radiated susceptibility of equipment, subystems and systems (whose dimensions are less than 3 m x 6 m x 18 m) in the frequency range 10 kHz - 20 MHz. Several large TEM cells have been designed and constructed by various organizations for EMP and high power CW testing. Two cell designs and associated instrumentation are included for example purposes in this report. Other cell configurations have also been constructed. Users should consult the literature before undertaking a project of this magnitude for other cell and instrumentation designs.
Standard

Vehicle Electromagnetic Immunity—Power Line Magnetic Fields

2010-01-07
HISTORICAL
J551/17_201001
This SAE Standard specifies the test methods and procedures for testing passenger cars and commercial vehicles to magnetic fields generated by power transmission lines and generating stations. SAE J551-1 specifies general information, definitions, practical use, and basic principles of the test procedure.
Standard

Vehicle Electromagnetic Immunity—Electrostatic Discharge (ESD)

2009-06-29
HISTORICAL
J551/15_200906
This SAE Standard specifies the ESD test methods and procedures necessary to evaluate electronic modules intended for vehicle use. It describes test procedures for evaluating electronic modules in complete vehicles. A procedure for verifying the simulator that is used to generate the electrostatic discharges is given in Appendix A. Functional status classifications for immunity to ESD are given in Appendix B.
Standard

Vehicle Electromagnetic Immunity--On-Board Transmitter Simulation

2009-08-03
CURRENT
J551/12_200908
This part of SAE J551 specifies on-board transmitter simulation test methods and procedures for testing passenger cars and commercial vehicles. The electromagnetic disturbances considered in this part of SAE J551 are limited to continuous narrow band electromagnetic fields. SAE J551/1 specifies general, definitions, practical use, and basic principles of the test procedure.
Standard

Vehicle Electromagnetic Immunity - Power Line Magnetic Fields

2015-07-22
CURRENT
J551/17_201507
This SAE Standard specifies the test methods and procedures for testing passenger cars and commercial vehicles to magnetic fields generated by power transmission lines and generating stations. SAE J551-1 specifies general information, definitions, practical use, and basic principles of the test procedure.
Standard

Vehicle Electromagnetic Immunity - Off-Vehicle Source

2010-03-09
CURRENT
J551/11_201003
This part of SAE J551 specifies off-vehicle radiation source test methods and procedures for testing passenger cars and commercial vehicles. Two methods for calibrating electromagnetic fields are defined in the document: a substitution method and a closed-loop method. The substitution method is the method most commonly used. SAE J551-1 specifies general, definitions, practical use, and basic principles of the test procedure.
Standard

Vehicle Electromagnetic Immunity - Electrostatic Discharge (ESD)

2020-05-29
CURRENT
J551/15_202005
This SAE Standard specifies the ESD test methods and procedures necessary to evaluate electronic modules intended for vehicle use. It describes test procedures for evaluating electronic modules in complete vehicles. A procedure for verifying the simulator that is used to generate the electrostatic discharges is given in Appendix A. Functional status classifications for immunity to ESD are given in Appendix B.
Standard

Vehicle Electromagnetic Immunity - Electrostatic Discharge (ESD)

2015-09-17
HISTORICAL
J551/15_201509
This SAE Standard specifies the ESD test methods and procedures necessary to evaluate electronic modules intended for vehicle use. It describes test procedures for evaluating electronic modules in complete vehicles. A procedure for verifying the simulator that is used to generate the electrostatic discharges is given in Appendix A. Functional status classifications for immunity to ESD are given in Appendix B.
Standard

VEHICLE ELECTROMAGNETIC RADIATED SUSCEPTIBILITY TESTING USING A LARGE TEM CELL

1982-08-01
HISTORICAL
J1407_198208
This information report gives the procedures for use and operation of a large transverse electromagnetic (TEM) mode cell for the determination of electromagnetic (EM) radiated susceptibility of equipment, subsystems and systems (whose dimensions are less than 3 m × 6 m × 18 m) in the frequency range 10 kHz–20 MHz. Several large TEM cells have been designed and constructed by various organizations for EMP and high power CW testing. Two cell designs and associated instrumentation are included for example purposes in this report. Other cell configurations have also been constructed. Users should consult the literature before undertaking a project of this magnitude for other cell and instrumentation designs.
Standard

VEHICLE ELECTROMAGNETIC RADIATED SUSCEPTIBILITY TESTING USING A LARGE TEM CELL

1988-03-01
HISTORICAL
J1407_198803
This information report gives the procedures for use and operation of a large transverse electromagnetic (TEM) mode cell for the determination of electromagnetic (EM) radiated susceptibility of equipment, subsystems and systems (whose dimensions are less than 3 m × 6 m × 18 m) in the frequency range 10 kHz - 20 MHz. Several large TEM cells have been designed and constructed by various organizations for EMP and high power CW testing. Two cell designs and associated instrumentation are included for example purposes in this report. Other cell configurations have also been constructed. Users should consult the literature before undertaking a project of this magnitude for other cell and instrumentation designs.
Standard

Test Limits and Methods of Measurement of Radio Disturbance Characteristics of Vehicles and Devices, Broadband and Narrowband, 150 kHz to 1000 MHz

2006-09-27
CURRENT
J551/4_200609
This SAE Standard contains test limits and procedures for the measurement of radio disturbances in the frequency range of 150 kHz to 1000 MHz. The document applies to any electronic/electrical component intended for use in vehicles. Refer to International Telecommunications Union (ITU) Publications for details of frequency allocations. The test limits are intended to provide protection for receivers installed in a vehicle from disturbances produced by components/ modules in the same vehicle. The receiver types to be protected are: broadcast radio and TV, land-mobile radio, radio telephone, amateur and citizens' radio. The limits in this document are recommended and subject to modification as agreed between the vehicle manufacturer and the component supplier. This document shall also be applied by manufacturers and suppliers of components and equipment which are to be added and connected to the vehicle harness or to an on-board power connector after delivery of the vehicle.
Standard

ROAD VEHICLES—ELECTRICAL DISTURBANCES BY NARROWBAND RADIATED ELECTROMAGNETIC ENERGY—COMPONENT TEST METHODS PART 21—ABSORBER-LINED CHAMBER

1994-10-01
HISTORICAL
J1113/21_199410
This part of SAE J1113 specifies test methods and procedures for testing electromagnetic immunity (of vehicle radiation sources) of electronic components for passenger cars and commercial vehicles. To perform this test method, the electronic module along with the wiring harness (prototype or standard test harness) and peripheral devices will be subjected to the electromagnetic disturbance generated inside an absorber-lined chamber. The electromagnetic disturbances considered in this part of SAE J1113 are limited to continuous narrowband electromagnetic fields. Immunity measurements of complete vehicles are generally only performed at the vehicle manufacturer. The reasons, for example, are high costs of a large absorber-lined chamber, preserving the secrecy of prototypes, or the large number of different vehicle models. Therefore, for research, development and quality control, a laboratory measuring method shall be applied by the manufacturers.
Standard

Measurement of Radiated Emissions from Integrated Circuits—TEM/Wideband TEM (GTEM) Cell Method; TEM Cell (150 kHz to 1 GHz), Wideband TEM Cell (150 kHz to 8 GHz)

2011-06-17
HISTORICAL
J1752/3_201106
This measurement procedure defines a method for measuring the electromagnetic radiation from an integrated circuit (IC). The IC being evaluated is mounted on an IC test printed circuit board (PCB) that is clamped to a mating port (referred to as a wall port) cut in the top or bottom of a TEM or wideband TEM (GTEM) cell. The test board is not in the cell as in the conventional usage but becomes a part of the cell wall. This method is applicable to any TEM or GTEM cell modified to incorporate the wall port; however, the measured RF voltage is affected by the septum to test board (wall) spacing. This procedure was developed using a 1 GHz TEM cell with a septum to wall spacing of 45 mm and a GTEM cell with average septum to wall spacing of 45 mm over the port area. Other cells may not produce identical spectral output but may be used for comparative measurements, subject to their frequency and sensitivity limitations.
Standard

Measurement of Radiated Emissions from Integrated Circuits—TEM/Wideband TEM (GTEM) Cell Method; TEM Cell (150 kHz to 1 GHz), Wideband TEM Cell (150 kHz to 8 GHz)

2017-09-22
CURRENT
J1752/3_201709
This measurement procedure defines a method for measuring the electromagnetic radiation from an integrated circuit (IC). The IC being evaluated is mounted on an IC test printed circuit board (PCB) that is clamped to a mating port (referred to as a wall port) cut in the top or bottom of a TEM or wideband TEM (GTEM) cell. The test board is not in the cell as in the conventional usage but becomes a part of the cell wall. This method is applicable to any TEM or GTEM cell modified to incorporate the wall port; however, the measured RF voltage is affected by the septum to test board (wall) spacing. This procedure was developed using a 1 GHz TEM cell with a septum to wall spacing of 45 mm and a GTEM cell with average septum to wall spacing of 45 mm over the port area. Other cells may not produce identical spectral output but may be used for comparative measurements, subject to their frequency and sensitivity limitations.
Standard

Measurement of Radiated Emissions from Integrated Circuits—Surface Scan Method (Loop Probe Method) 10 MHz to 3 GHz

2016-09-16
CURRENT
J1752/2_201609
This SAE Recommended Practice defines a method for evaluating the near field electric or magnetic component of the electromagnetic field at the surface of an integrated circuit (IC). This technique is capable of providing a detailed pattern of the RF sources internal to the IC. The resolution of the pattern is determined by the characteristics of the probes used and the precision of the mechanical probe positioner. The method is usable over the 10 MHz to 3 GHz frequency range with existing probe technology. The probe is mechanically scanned according to a programmed pattern in a plane parallel or perpendicular to the IC surface and the data is computer processed to provide a color-enhanced representation of field strength at the scan frequency. This procedure is applicable to measurements from an IC mounted on any circuit board that is accessible to the scan probe. For comparisons, the standardized test board shall be used.
Standard

Measurement of Radiated Emissions from Integrated Circuits—Surface Scan Method (Loop Probe Method) 10 MHz to 3 GHz

2011-06-24
HISTORICAL
J1752/2_201106
This SAE Recommended Practice defines a method for evaluating the near field electric or magnetic component of the electromagnetic field at the surface of an integrated circuit (IC). This technique is capable of providing a detailed pattern of the RF sources internal to the IC. The resolution of the pattern is determined by the characteristics of the probes used and the precision of the mechanical probe positioner. The method is usable over the 10 MHz to 3 GHz frequency range with existing probe technology. The probe is mechanically scanned according to a programmed pattern in a plane parallel or perpendicular to the IC surface and the data is computer processed to provide a color-enhanced representation of field strength at the scan frequency. This procedure is applicable to measurements from an IC mounted on any circuit board that is accessible to the scan probe. For comparisons, the standardized test board shall be used.
Standard

MEASUREMENT OF ELECTROMAGNETIC RADIATION FROM MOTOR VEHICLES (20-1000 MHz)

1968-08-01
HISTORICAL
J551A_196808
This standard covers the measurement of radiation from all motor vehicle sources (including auxiliary engines) with the exception of short duty cycle equipment, such as starting motors, window regulators, turn signals, etc., over a frequency range of 20-1000 MHz.
X