Refine Your Search

Search Results

Viewing 1 to 10 of 10
Technical Paper

The Highway Safety Research Institute Dummy Compared with General Motors Biofidelity Recommendations and the Hybrid II Dummy

1974-02-01
740588
Two Highway Safety Research Institute (HSRI) dummies were tested and evaluated. Based on the analysis given, the HSI dummy should not be used for vehicle qualification testing. However, many of its components offer viable alternatives for future dummy development. The dummy was found to have inadequate biomechanical fidelity in the head, neck, and chest, although its characteristics were very promising and, as a whole, biomechanically superior to the Hybrid II. Its repeatability and reproducibility in dynamic component tests were better than the Hybrid II dummy. In particular, the HSRI friction joints were outstanding in repeatability and had a significant advantage in usability in that they do not require resetting between tests. In three-point harness and ACRS systems tests, the values of injury criteria produced by the HSRI dummy were generally lower than those obtained with the Hybrid II, especially the femur loads in the ACRS tests.
Technical Paper

Old Problems and New Approaches in Seating Biomechanics

1986-02-24
860049
Human accommodation, has undergone rapid changes in the past few years which are outdistancing current concepts, data and design tools. This paper examines the basis of current problems in the application of these tools to the design of safe and comfortable seats. Examples of the types of new data needed are given and the discussion proposes new paths to solve current problems.
Technical Paper

Measuring and Modeling Support Forces of People to Assist in the Development of the ASPECT Manikin Weighting

1999-03-01
1999-01-0961
The ASPECT (Automotive Seat and Package Evaluation and Comparison Tools) Program has developed the next generation SAE 3-D H-Point testing manikin. During the development of the ASPECT manikin, new data were collected on how people loaded different regions of a seat and how these loads varied with different postures. These data, along with a computer model of the ASPECT manikin, were used to assist in the development of a human-like weight distribution for the new seating device, the ASPECT manikin.
Technical Paper

Measurement and Analysis of Human Thigh and Buttocks Contours for ASPECT Manikin Development

1999-03-01
1999-01-0964
To provide contours for the new ASPECT manikin, the contours of the thighs and buttocks of mid-size male subjects were measured using a specially built chair. The subjects' body surfaces that were not in contact with the chair and their postures were measured using a video-based position measurement system. Using computer aided design methods, the measured contours were splined and sectioned relative to the local anatomical coordinates for each subject. These local sections were combined and analyzed, with comparison to SAE J826 manikin contours, to provide a thigh and buttocks contour for the ASPECT manikin that represent the mid-size male.
Technical Paper

Geometric, Inertial, and Joint Characteristics of Two Part 572 Dummies for Occupant Modeling

1977-02-01
770937
The geometric, inertial, and joint characteristics of two Part 572 crash test dummies were measured to provide input to the MVMA 2-D occupant model. Segments of the dummies were defined which correspond to the links of the model and coordinate axes were defined for each segment. The center of gravity of each segment was located and its coordinates were measured along with the locations of joint centers, instrument mounts, and other significant geometric features. The mass moment of inertia for each segment about a lateral axis through its center of gravity was measured. The geometric and inertial measurements are presented on summary sheets for each segment with the hardware definition, coordinate system, and special notes for that particular segment. These summary sheets present the data in a format that is readily usable for defining computer model input.
Technical Paper

Development of Human Back Contours for Automobile Seat Design

1997-02-24
970590
Driver and passenger comfort, as related to automotive seats, is a growing issue in the automotive industry. As this trend continues, automotive seat designers and developers are generating a greater need for more anthropometrically accurate tools to aid them in their work. One tool being developed is the JOHN software program that utilizes three-dimensional solid objects to represent humans in seated postures. Contours have been developed to represent the outside skin surfaces of three different body types in a variety of postures in the sagittal plane. These body types include: the small female, the average male, and the large male.
Technical Paper

Definition and Development of A Crash Dummy Head

1974-02-01
741193
Crash test dummies serve as human surrogates in automotive crash simulations, and accelerations monitored in the heads of these dummies are used for assessment of human head injury hazard. For these acceleration measurements to be meaningful indicators of head injury, the impact response of the human head must be a part of dummy head design. This paper describes the conception, design, and development of a crash test dummy head. Geometric, inertial, and performance requirements based on biomechanical information are presented and discussed. The head design concept is compatible with current head injury assessment procedures, and the configuration is based on the GM Research skull and head geometry models. The manufacture and development are described, and the test procedures and results are presented and discussed with reference to the biomechanical and functional requirements. The resulting dummy head is shown to comply with these requirements.
Technical Paper

Biomechanical Design and Evaluation of Truck Seats

2000-12-04
2000-01-3406
The design and evaluation of seating has been limited by the available technologies to measure the mechanical interaction between a seat and its user. For many years, representation of the seated torso has been by two standardized measurement manikins from the American National Standards Institute (ANSI)1 for office seating and the Society of Automotive Engineers (SAE)2 for vehicle seating. Most office and automotive seat backs recline about a single point; this motion can be measured with the available manikins. However, both the ANSI and the SAE manikins do not represent the natural anatomical movements of the upper torso (thorax) relative to the lower torso (pelvis) that occur with spinal articulation. Current tools that are useful for seat design and evaluation include the biomechanical models3,4 and experimental test methods5, 6,7 that have been developed at Michigan State University's (MSU) Biomechanical Design Research Laboratory (BDRL).
Technical Paper

Anthropometric Basis of the GM ATD 502 Crash Test Dummy

1975-02-01
750429
Human anthropometry was used as input to the design of the GM ATD 502 crash test dummy. The spinal column of an average adult male was located for an erect seated position leading to guidelines for placement of dummy components and sectioning of the dummy into segments. The weight and weight distribution of these dummy segments were defined based on anthropometric data. These results provide some assurance that the size, relative location, and weight distribution of dummy structures are representative of human characteristics.
Technical Paper

ASPECT: The Next-Generation H-Point Machine and Related Vehicle and Seat Design and Measurement Tools

1999-03-01
1999-01-0962
The ASPECT program was conducted to develop new Automotive Seat and Package Evaluation and Comparison Tools. This paper presents a summary of the objectives, methods, and results of the program. The primary goal of ASPECT was to create a new generation of the SAE J826 H-point machine. The new ASPECT manikin has an articulated torso linkage, revised seat contact contours, a new weighting scheme, and a simpler, more user-friendly installation procedure. The ASPECT manikin simultaneously measures the H-point location, seat cushion angle, seatback angle, and lumbar support prominence of a seat, and can be used to make measures of seat stiffness. In addition to the physical manikin, the ASPECT program developed new tools for computer-aided design (CAD) of vehicle interiors. The postures and positions of hundreds of vehicle occupants with a wide range of body size were measured in many different vehicle conditions.
X