Refine Your Search

Search Results

Viewing 1 to 13 of 13
Technical Paper

The Effect of Fuel Volatility on HCCI Using Simultaneous Formaldehyde and OH PLIF

2004-10-25
2004-01-2948
Simultaneous formaldehyde and OH PLIF have been applied in a direct-injected HCCI engine. The engine is a 0.5 l single-cylinder optical engine equipped with EGR system. PLIF measurements were performed with the engine run with two different fuels of low and high volatility, respectively. Different ratios of EGR were also examined. The aim of the study was to investigate how fuels with different volatility and EGR affect the HCCI combustion and measurements were performed for early and late injection timings. Measurements are presented for different injection timings showing formaldehyde and OH from start of injection until late in the expansion stroke. Also, formaldehyde distributions obtained from after the low temperature regime and before the high temperature regime are studied for different tuning of the start of injection from 300CAD to 20CAD before top dead center.
Technical Paper

Quantitative Imaging of Equivalence Ratios in DME Sprays Using a Chemically Preheated Combustion Vessel

2000-10-16
2000-01-2785
Dimethyl Ether (DME) has proved to be a promising fuel for diesel engines. It virtually eliminates particulate emissions and reduces the formation of nitrogenous oxides, without negatively affecting engine efficiency. Obtaining a deeper understanding of the mechanisms behind these properties is thus highly desirable. Various authors have suggested that the low NO emissions associated with DME are an effect of the mixing conditions, which are thought to differ from those of diesel sprays. To examine this, laser-Rayleigh imaging was employed for quantitative measurement of the local equivalence ratios in DME sprays. The quantitative images were analyzed using a statistical approach, in which probability distributions of ϕ-values for burning and for non-reacting sprays were compared. It was concluded that the diffusion flame is established in the stoichiometeric or slightly lean regions of the spray.
Technical Paper

Optical Diagnostics of HCCI and UNIBUS Using 2-D PLIF of OH and Formaldehyde

2005-04-11
2005-01-0175
Simultaneous OH- and formaldehyde planar-LIF measurements have been performed in an optical engine using two laser sources working on 283 and 355 nm, respectively. The measurements were performed in a light duty Diesel engine, using n-heptane as fuel, converted to single-cylinder operation and modified for optical access. It was also equipped with a direct injection common rail system as well as an EGR system. The engine was operated in both HCCI mode, using a single fuel injection, and UNIBUS (Uniform Bulky Combustion System) mode, using two injections of fuel with one of the injections at 50 CAD before TDC and the other one just before TDC. The OH and formaldehyde LIF images were compared with the heat-release calculated from the pressure-traces. Analyses of the emissions, for example NOx and HC, were also performed for the different operating conditions.
Technical Paper

Optical Diagnostics of HCCI and Low-Temperature Diesel Using Simultaneous 2-D PLIF of OH and Formaldehyde

2004-10-25
2004-01-2949
Simultaneous OH- and formaldehyde planar-LIF measurements have been performed in an optical engine using two laser sources working on 283 and 355 nm, respectively. The engine used for the measurements was a car Diesel engine converted to single-cylinder operation and modified for optical access. The fuel, n-heptane, was injected by a direct injection common rail system and the engine was also fitted with an EGR system. The engine was operated in both HCCI mode and Diesel mode. Due to the low load, the Diesel mode resulted in low-temperature Diesel combustion and because of limitations in maximum pressure and maximum rate of pressure increase of the optical engine, the Diesel mode was run at a higher EGR percentage than the HCCI mode to slow down the combustion. A third mode, pilot combustion, was also investigated. This pilot combustion is created by an injection at 30 CAD before TDC followed by a second injection just before TDC.
Technical Paper

Laser-Rayleigh Imaging of DME Sprays in an Optically Accessible DI Diesel Truck Engine

2001-03-05
2001-01-0915
Laser-Rayleigh imaging has been employed to measure the relative fuel concentration in the gaseous jet region of DME sprays. The measurements were performed in an optically accessible diesel truck engine equipped with a common rail injection system. A one-hole nozzle was used to guarantee that the recorded pressure history was associated with the heat release in the imaged spray. To compensate for the low compression ratio in the modified engine the inlet air was preheated. Spray development was studied for two levels of preheating, from the start of injection to the point where all fuel was consumed. The results indicate that there is a strong correlation between the amount of unburned fuel present in the cylinder and the rate of heat release at a given time. The combustion can not be described as purely premixed or purely mixing-controlled at any time, but always has an element of both. After all fuel appears to have vanished there is still an extended period of heat release.
Technical Paper

Impact of Mechanical Deformation due to Pressure, Mass, and Thermal Forces on the In-Cylinder Volume Trace in Optical Engines of Bowditch Design

2011-01-19
2011-26-0082
A detailed investigation is made of the impact of mechanical deformation on the in-cylinder volume as function of crank angle degree in an optical engine of Bowditch design. The squish height is found to change linearly with mass and pressure forces. It increases due to pressure forces and decreases due to mass forces. The thermal forces have an impact on the squish height but it is not clear in what direction. The volume change caused by deformations did not change the calculated load significantly but gave errors during heat release calculations. Two different strategies to reduce these errors are presented.
Technical Paper

Heat Release Comparison Between Optical and All-Metal HSDI Diesel Engines

2008-04-14
2008-01-1062
Experiments are performed in optical engines in order to understand the combustion process in standard engines. In spite of this, little work has been done to verify that the results from optical engines are representative for a standard engine. The wall heat losses in optical engines are lower than in all-metal engines due to the lower heat conductivity of optical parts and a less efficient cooling system. Furthermore, optical engines often have larger crevice volumes due to a lower position of the piston rings. The present investigation studies how these differences affect the heat release and emissions in optical HSDI diesel engines. Five different engine configurations are studied: an optical engine of Bowditch design with two different squish heights, the same engine fitted with a metal piston, the same engine with all quartz parts replaced with metal components and, finally, a standard diesel engine. It is found that the use of optical parts affect the combustion process.
Journal Article

Effect of Injection Strategy on Cold Start Performance in an Optical Light-Duty DI Diesel Engine

2009-09-13
2009-24-0045
The present study investigates cold start at very low temperatures, down to −29 deg C. The experiments were conducted in an optical light duty diesel engine using a Swedish class 1 environmental diesel fuel. In-cylinder imaging of the natural luminescence using a high speed video camera was performed to get a better understanding of the combustion at very low temperature conditions. Combustion in cold starting conditions was found to be asymmetrically distributed in the combustion chamber. Combustion was initiated close to the glow plug first and then transported in the swirl direction to the adjacent jets. A full factorial study was performed on low temperature sensitivity for cold start. The effects of cooling down the engine by parts on stability and noise were studied. Furthermore, different injection strategies were investigated in order to overcome the limited fuel evaporation process at very low temperatures.
Journal Article

Challenges for In-Cylinder High-Speed Two-Dimensional Laser-Induced Incandescence Measurements of Soot

2011-04-12
2011-01-1280
Laser-Induced Incandescence (LII) has traditionally been considered a straightforward and reliable optical diagnostic technique for in-cylinder soot measurements. As a result, it is nowadays even possible to buy turn-key LII measurement systems. During recent years, however, attention has been drawn to a number of unresolved challenges with LII. Many of these are relevant mostly for particle sizing using time-resolved LII, but also two-dimensional soot volume fraction measurements are affected, especially in regions with high soot concentrations typically found in combustion engines. In this work the focus is on the specific challenges involved in performing high-repetition rate measurements with LII in diesel engines. All the mentioned issues might not be possible to overcome but they should nevertheless be known and their potential impact should be considered.
Journal Article

Analysis of the Correlation Between Engine-Out Particulates and Local Φ in the Lift-Off Region of a Heavy Duty Diesel Engine Using Raman Spectroscopy

2009-04-20
2009-01-1357
The local equivalence ratio, Φ, was measured in fuel jets using laser-induced spontaneous Raman scattering in an optical heavy duty diesel engine. The measurements were performed at 1200 rpm and quarter load (6 bar IMEP). The objective was to study factors influencing soot formation, such as gas entrainment and lift-off position, and to find correlations with engine-out particulate matter (PM) levels. The effects of nozzle hole size, injection pressure, inlet oxygen concentration, and ambient density at TDC were studied. The position of the lift–off region was determined from OH chemiluminescence images of the flame. The liquid penetration length was measured with Mie scattering to ensure that the Raman measurement was performed in the gaseous part of the spray. The local Φ value was successfully measured inside a fuel jet. A surprisingly low correlation coefficient between engine-out PM and the local Φ in the reaction zone were observed.
Technical Paper

Analysis of Smokeless Spray Combustion in a Heavy-Duty Diesel Engine by Combined Simultaneous Optical Diagnostics

2009-04-20
2009-01-1353
A heavy duty diesel engine operating case producing no engine-out smoke was studied using combined simultaneous optical diagnostics. The case was close to a typical low load modern diesel operating point without EGR. Parallels were drawn to the conceptual model by Dec and results from high-pressure combustion vessels. Optical results revealed that no soot was present in the upstream part of the jet cross-section. Soot was only observed in the recirculation zones close to the bowl perimeter. This indicated very slow soot formation and was explained by a significantly higher air entrainment rate than in Dec's study. The local fuel-air equivalence ratio, Φ, at the lift-off length was estimated to be 40% of the value in Dec's study. The lower Φ in the jet produced a different Φ -T-history, explaining the soot results. The increased air entrainment rate was mainly due to smaller nozzle holes and increased TDC density.
Journal Article

Analysis of Errors in Heat Release Calculations Due to Distortion of the In-Cylinder Volume Trace from Mechanical Deformation in Optical Diesel Engines

2012-09-10
2012-01-1604
Optical engines of Bowditch design may suffer from distortion of the in-cylinder volume trace due to mechanical deformation from inertial, pressure and thermal forces. Errors in heat release calculation associated with such deformation were investigated in detail. The deformations were quantified by measuring the squish height during operation using high speed video. Deformations of all-metal engines were also estimated for comparison. The volume change caused by deformations did not change the calculated load significantly but caused errors in the heat release calculations both for optical and all metal engines. The errors at a given operating condition are smaller for all-metal engines but the importance is not necessarily smaller, since these engines normally are operated at higher loads. The errors can be eliminated by a corrected in-cylinder volume equation and a subtraction of heat release from a motored case.
Journal Article

Analysis of EGR Effects on the Soot Distribution in a Heavy Duty Diesel Engine using Time-Resolved Laser Induced Incandescence

2010-10-25
2010-01-2104
The soot distribution as function of ambient O₂ mole fraction in a heavy-duty diesel engine was investigated at low load (6 bar IMEP) with laser-induced incandescence (LII) and natural luminosity. A Multi-YAG laser system was utilized to create time-resolved LII using 8 laser pulses with a spacing of one CAD with detection on an 8-chip framing camera. It is well known that the engine-out smoke level increases with decreasing oxygen fraction up to a certain level where it starts to decrease again. For the studied case the peak occurred at an O₂ fraction of 11.4%. When the oxygen fraction was decreased successively from 21% to 9%, the initial soot formation moved downstream in the jet. At the lower oxygen fractions, below 12%, no soot was formed until after the wall interaction. At oxygen fractions below 11% the first evidence of soot is in the recirculation zone between two adjacent jets.
X