Refine Your Search

Topic

Search Results

Standard

When and How Shall Oxygen be Used on Aircraft”

2015-09-22
WIP
AIR6256
The aim of this document is to provide a comprehensive synopsis of regulations applicable to aircraft oxygen systems. The context of physiological requirements, international regulations, operational requirements and airworthiness standards is shown to understand the role of aircraft oxygen systems and to demonstrate under which circumstances is needed on aircraft. With regards to National Aviation Regulations States are committed to the Convention on International Aviation (Chicago Convention). The majority of states have adopted, with some deviations, FAA and EASA systems including operational and airworthiness requirements. Accordingly the extent of this document is primarily focused on FAA/EASA requirements.
Standard

Transfilling and Maintenance of Oxygen Cylinders

1998-12-01
HISTORICAL
AIR1059B
The purpose of this document is to list the best available information and guidelines for the qualification of personnel who are responsible for the filling of fixed or portable aircraft oxygen cylinders.
Standard

Technical Approaches for Oxygen Equipment Certification

2013-03-07
WIP
ARP6244
This document describes technical approaches that can be applied to show that proposed oxygen equipment and systems achieve suitable oxygenation in users. These approaches can be used to demonstrate that items under test meet performance criteria sufficient to justify certification for use in aircraft applications.
Standard

Regulatory Requirements Covering the Use of Breathing Oxygen in Aircraft

2002-02-15
HISTORICAL
AIR1389A
This report presents, paraphrased in tabular format, an overview of the Federal Aviation Regulations (FAR) and the Joint Aviation Regulations (JAR) for aircraft oxygen systems. It is intended as a ready reference for those considering the use of oxygen in aircraft and those wishing to familiarize themselves with the systems requirements for existing aircraft. This document is not intended to replace the oxygen related FAR/JAR but rather to index them in some order. For detailed information, the user is referred to the current issue of the relevant FAR/JAR paragraph referenced in this report.
Standard

Reducers, Oxygen Pressure

1999-07-01
HISTORICAL
AS17852
This specification covers the requirements for two types of oxygen pressure reducers.
Standard

Reducers, Oxygen Pressure

2012-07-24
CURRENT
AS17852A
This specification covers the requirements for two types of oxygen pressure reducers.
Standard

Provisions of Medical Oxygen for Aircraft Occupants

2017-01-18
WIP
AIR6190A
This document provides information on provisions for passengers with disabilities on board commercial aircraft. In this context the term "provision of medical oxygen" shall be understood as application of oxygen on board an aircraft not linked to (post) decompression in the sense of Airworthiness Requirements FAR/CS 25 and Operational Regulations of FAR 121/135. Information about available equipment and physiological treatment in clinical practice will be provided in this document. It covers the use of oxygen concentrators according to guidance of FAR Advisory Circular AC120-95.
Standard

Provisions of Medical Oxygen for Aircraft Occupants

2012-06-06
CURRENT
AIR6190
This document provides information on provisions for passengers with disabilities on board commercial aircraft. In this context the term "provision of medical oxygen" shall be understood as application of oxygen on board an aircraft not linked to (post) decompression in the sense of Airworthiness Requirements FAR/CS 25 and Operational Regulations of FAR 121/135. Information about available equipment and physiological treatment in clinical practice will be provided in this document. It covers the use of oxygen concentrators according to guidance of FAR Advisory Circular AC120-95.
Standard

Performance Requirements for Full Face Quick Donning Masks

2018-04-04
WIP
AS6814
Purpose of this standard is to provide minimum performance requirements of a Full Face Quick Donning Mask Assembly (FFQDM) with integrated regulator including appropriate stowage facility regarding functionality under conditions of aircraft environments. Function and performance requirements shall take into account varying modes of use and handling during aircraft operation according to operational requirements.
Standard

Passenger Oxygen Mask

1999-01-01
CURRENT
AS8025A
This standard covers oronasal type masks which use a continuous flow oxygen supply. Each such mask comprises a facepiece with valves as required, a mask suspension device, a reservoir, or rebreather bag (when used), a length of tubing for connection to the oxygen supply source, and a means for allowing the crew to determine if oxygen is being delivered to the mask. The assembly shall be capable of being stowed suitably to meet the requirements of its intended use.
Standard

Oxygen considerations for flight into high elevation airports

2015-11-30
WIP
ARP6527
The scope of this document is to provide guidance concerning the use of oxygen when flying into and out of high elevation airports. Normally for aircraft operations that fly at high altitude, oxygen requirements involving a decompression are generally easy to understand and follow because of the increased delta between cabin and ambient pressures. This document is intended to address a transition zone where cabin and ambient pressures are closely the same and oxygen usage can be compounded by physiologic subjectivity that often accompanies hypoxia. This transition zone is further diluted by regulations which are based not on science but rather sociological mores often not supported by empirical science. An example of this is reflected by differential regulatory requirements between CFR’s 91, 121 and 135. Operators who fly into these high altitude airports will undoubtedly be required to address the inherent threats and errors associated with this transition zone.
Standard

Oxygen Systems and Components Maintenance and Service Practices

2014-05-08
WIP
ARP5932
This SAE Aerospace Recommended Practice (ARP) will provide general guidelines and procedures for servicing and maintaining oxygen systems. Such methods and procedures may be applied to gaseous, liquid, chemical and portable oxygen systems. These guidelines and recommendations will be provided to engineering and maintenance personnel for airlines, modification centers and third party maintenance contractors, to be used while performing maintenance on oxygen systems and components.
Standard

Oxygen System and Component Cleaning

2017-12-01
WIP
ARP1176B
This SAE Aerospace Recommended Practice (ARP) provides recommended practices for cleaning aircraft oxygen equipment such as tubing, pieces, parts (including regulator and valve parts), cylinders and ground-based equipment that may be used to support aircraft oxygen systems. This revision introduces a cleanliness coding scheme that can be referenced as a requirement, and/or referenced to identify compliance to meeting such a requirement. These methods may apply to gaseous and liquid oxygen equipment. This document specifies work area details, methods to select suitable cleaning agents, cleaning methods, test methods to verify cleanliness level, and methods of packaging the components and parts after cleaning. Technicians designated to clean oxygen equipment must be qualified and trained to clean oxygen equipment. This ARP is applicable to metallic and non-metallic parts.
Standard

Oxygen System Fill/Check Valve

1997-12-01
CURRENT
AS1225A
This SAE Aerospace Standard (AS) defines minimum standards of design, construction, and performance for two types of permanently installed, high pressure 12,800 kPa (1850 psig) and 13,800 kPa (2000 psig) oxygen system cylinder fill valves used in commercial aircraft. Refer to Purchaser's Specification for Requirements which are beyond the scope or level of detail provided in this document. One valve has an adjustable pressure sensitive closing valve to automatically control the final pressure for a correct amount of oxygen in the system. The second valve incorporates an automatic shutoff feature designed to limit system overpressurization in the event maintenance personnel do not stop system filling at the correct pressure. The intent of the fill valves is to control the rate of fill to limit the rise in temperature caused by compression heating to acceptable values, prevent oxygen back flow and prevent the ingestion of foreign matter that could cause contamination of the system.
Standard

Oxygen Sensor Technologies

2014-10-23
WIP
AIR5933
This AIR5933 gives an overview of contemporary technologies to determine the oxygen concentration respectively partial pressure in air. The aerospace application and its special constraints have been emphasized regarding weight, power supply, overall size, reliability and safety, cost and useful life.
X