This test method provides performance data on candidate insulation systems as a function of time and temperature. These data give engineering information on the wire insulation candidate relative to the performance of materials already in use with a backlog of experience. These tests expose candidate insulation systems to a wide range of temperatures for short and long periods of time, while measuring the degradation of its physical properties. For aerospace use, end-point proof tests include mandrel bend, water soak, and dielectric integrity.
This SAE Aerospace Informatino Report (AIR) focuses on how long-term exposure of high voltage below and above wire insulation corona inception voltage (CIV) impacts round wire insulation life. This AIR will be updated when additional data is available.
This SAE Aerospace Information Report provides additional information and background in regard to the dimensional life of a heat-shrinkable sleeve. The term dimensional life is newly introduced in AS23053 to relate to the dimensional stability instead of the material stability often associated or referred to as the “shelf life.” When the material exceeds such shelf life, it becomes harmful or non-functional.
This SAE Aerospace Standard (AS) covers the requirements for thermocouple extension cable. Manufacturers of primary thermocouple wire in accordance with this specification must be qualified to the similar wire type specified in Table 1.
This SAE Aerospace Standard (AS) covers the requirements for thermocouple extension cable. Manufacturers of primary thermocouple wire in accordance with this specification must be qualified to the similar wire type specified in Table 1.
This SAE Aerospace Standard (AS) covers the requirements for thermocouple extension cable. Manufacturers of primary thermocouple wire in accordance with this specification must be qualified to the similar wire type specified in Table 1.
This specification covers 600 V heavy duty, portable, power, single and multiconductor, electrical cable for severe flexing service (see detail specifications for voltage limitations). The AS5756 insulation system has been used in aerospace ground power applications using 115/200 V (phase to neutral) at 400 Hz AC. Verification of the suitability of this product for use in other electrical system configurations (600 V, etc.) is the responsibility of the user.
This specification covers 600 V heavy duty, portable, power, single and multiconductor, electrical cable for severe flexing service (see detail specifications for voltage limitations). The AS5756 insulation system has been used in aerospace ground power applications using 115/200 V (phase to neutral) at 400 Hz AC. Verification of the suitability of this product for use in other electrical system configurations (600 V, etc.) is the responsibility of the user.
This specification covers 600-volt heavy duty, portable, power, single and multiconductor, electrical cable for severe flexing service (see detail specifications for voltage limitations).