Standard

Specification for O-Ring Materials Used with Hydraulic Connectors

2010-01-07
HISTORICAL
J515_201001
SAE J515 covers the specification for hydraulic O-ring material and properties and sizes applicable to face seal fittings, metric and inch stud ends, and four-bolt flange fittings. The standard includes a size code to allow industry and government agencies to order O-ring with a coded part number.
Standard

Specification for O-Ring Materials Used with Hydraulic Connectors

2015-11-24
CURRENT
J515_201511
SAE J515 covers the specification for hydraulic O-ring material and properties and sizes applicable to face seal fittings, metric and inch stud ends, and four-bolt flange fittings. The standard includes a size code to allow industry and government agencies to order O-ring with a coded part number.
Standard

Specification for O-Ring Face Seal Connectors: Part 3 - Requirements, Dimensions, and Tests for Steel Unions, Bulkheads, Swivels, Braze Sleeves, Caps, and Connectors with SAE J1926-2 Inch Stud Ends

2014-12-03
WIP
J1453/3
The three parts of SAE J1453 cover material, dimensional, and performance requirements of steel O-ring face seal (ORFS) connectors for tubing and the O-ring face seal interface and nut portion of hose stem assemblies for nominal tube diameters of 6 mm through 50 mm. SAE J1453-3 covers the requirements for O-ring face seal connectors to inch stud ends along with the associated adapters, bulkhead and union connectors. Inch hex dimensions of parts will be moved from the main document to an informative annex after 2013.
Standard

Specification for O-Ring Face Seal Connectors: Part 2 - Requirements, Dimensions, and Tests for Steel Unions, Bulkheads, Swivels, Braze Sleeves, Braze-on Tube Ends, Caps, and Connectors with ISO 6149-2 Metric Stud Ends and ISO 6162 4-Bolt Flange Heads

2018-08-23
WIP
J1453/2
The three parts of SAE J1453 cover material, dimensional, and performance requirements of steel O-ring face seal (ORFS) connectors for tubing and the O-ring face seal interface and nut portion of hose stem assemblies for nominal tube diameters of 6 mm through 38 mm and for nominal hose diameters 6.3 mm through 38 mm. SAE J1453-2 covers the requirements for “metric based” O-ring face seal connectors to metric stud ends along with the associated adapters, bulkhead and union connectors. Metric hex wrenching flats are used throughout this standard.
Standard

Lubrication Fittings

2018-10-22
WIP
J534
This SAE Standard covers complete general and dimensional specifications for the various types of lubrication fittings and related threaded components intended for general application in the automotive and allied fields.
Standard

Information Report for the Installation of Fluid Conductors and Connectors

2015-02-26
CURRENT
J2593_201502
This information report provides general information for installing and tightening fluid conductors and connectors. Following these guidelines, with the consistent proper use of torque wrenches, tightening procedures and correct torque levels will result in diminishing leaks and improving service life by avoiding hose twisting, tube binding, false torque and improper joint closures. Since many factors influence the pressure at which a hydraulic system will or will not perform satisfactorily, this report should not be used as a “standard” nor a “specification” and the values shown should not be construed as “guaranteed” minimums, maximums or absolutes. This document is an information report to help users by gathering available information from the various connector standards and publishing the information in one source for easy retrieval and applied common usage. This information report is primarily intended for mobile/stationary industrial equipment applications.
Standard

Flares for Tubing

2019-09-11
WIP
J533
This SAE Standard covers specifications and performance requirements for 37° and 45° single and double flares for tube ends intended for use with SAE J512, SAE J513, SAE J514, and ISO 8434-2 connectors. The flares described in this document are intended for use with SAE metallic tube materials. Considerations such as the effects of wall thickness selection for specific working pressures, identifying appropriate length of thread engagements for specific applications with mating connectors and other associated criteria, shall be the responsibility of the user. For applicable nominal reference working pressures for hydraulic tubing, see SAE J1065 and ISO 10763.
Standard

Fitting—O-Ring Face Seal

2009-01-13
CURRENT
J1453_200901
This SAE Standard covers material, dimensional, and performance requirements of steel O-ring face seal fittings for tubing and the O-ring face seal interface and nut portion of hose stem assemblies for nominal tube or hose diameters 6.35 mm (0.250 in) through 38.1 mm (1.500 in). These fittings are intended for general application and hydraulic systems on industrial equipment and commercial products, where elastomeric seals are acceptable to overcome leakage and variations in assembly procedures. These fittings are capable of providing leak-proof full flow connections in hydraulic systems operating from 95 kPa (28 in Hg) vacuum to working pressures shown in Table 1. Since many factors influence the pressure at which a hydraulic system will or will not perform satisfactorily, these values should not be construed as guaranteed minimums.
Standard

Connector for Fluid Power and General Use - Ports and Stud End with ASME B1.1 Threads and O-Ring Seal - Part 4: External Hex and Internal Hex Inch Port Plugs - Dimensions, Design, Test Methods and Requirements

2013-02-08
WIP
J1926/4
This part defines performance requirements, dimensions, and designs for -2 through -32 internal and external hex port plugs for use in SAE J1926-1 ports. Testing and usage through many years confirm the performance requirements of port plugs made from carbon steel. The port plugs were specified in SAE J514 without any performance requirements. They have been developed and tested to gain a 4:1 working pressure rating for industrial applications. In fluid power systems, power is transmitted and controlled through a fluid (liquid or gas) under pressure within an enclosed circuit. In general applications, a fluid may be conveyed under pressure. Components are connected through their threaded ports by stud ends on fluid conductor fittings to tubes and pipes or to hose fittings and hoses. For threaded ports and stud ends specified in new designs in hydraulic fluid power applications, only ISO 6149 shall be used.
Standard

Connections for Fluid Power and General Use - Hydraulic Couplings - Diagnostic

2019-12-04
WIP
J1502
SAE J1502 specifies dimensions, performance requirements, and test procedures for the male half of a diagnostic coupler with either a metric M14x1.5 or an inch 9/16–18 straight thread stud end. The coupler is designed for use with a mineral based hydraulic fluid. It is used on machines specified in SAE J1116. It does not apply to the mating hydraulic quick action couplings not on the machine. Diagnostic couplings in accordance with SAE J1502 may be used at a working pressure of 42 MPa. The permissible working pressure depends upon the materials, design, working conditions, application, etc. Conformance to the dimensional information in this part of SAE J1502 does not guarantee rated performance. Each manufacturer should perform testing according to the specification contained in this document to ensure that components comply with the performance rating.
Standard

Connections for Fluid Power and General Use - Hydraulic Couplings - Diagnostic

2013-05-03
CURRENT
J1502_201305
SAE J1502 specifies dimensions, performance requirements, and test procedures for the male half of a diagnostic coupler with either a metric M14×1.5 or an inch 9/16-18 straight thread stud end. The coupler is designed for use with a mineral based hydraulic fluid. It is used on machines specified in SAE J1116. It does not apply to the mating hydraulic quick action couplings not on the machine. Diagnostic couplings in accordance with SAE J1502 may be used at a working pressure of 42 MPa. The permissible working pressure depends upon the materials, design, working conditions, application, etc. Conformance to the dimensional information in this part of SAE J1502 does not guarantee rated performance. Each manufacturer should perform testing according to the specification contained in this document to ensure that components comply with the performance rating.