Standard

Truck Tractor Power Outlet for Trailer ABS

2019-12-17
CURRENT
J2247_201912
This SAE Recommended Practice identifies the minimum truck tractor electrical power output of the stop lamp and ABS (antilock brake system) circuits measured at the primary SAE J560 tractor trailer interface connector(s).
Standard

Seven-Conductor Cable for ABS Power

1998-06-01
HISTORICAL
J2394_199806
This SAE Standard establishes the minimum construction and performance requirements for seven-conductor 1/8-2/10-4/12 cable for use on trucks and trailers. Where appropriate, the document refers to two types of cables, (Type F and S, described later in the document), due to the variation in the performance demands of cables used in flexing and stationary applications.
Standard

Seven Conductor Cable for ABS Power--Truck and Bus

2007-06-22
HISTORICAL
J2394_200706
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8 2/10 4/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications. While the document's title refers to ABS Power to differentiate the document from the SAE J1067 standard that it supersedes, the scope applies to both the primary green cable for powering ABS and lighting and the yellow auxiliary cable of the same construction.
Standard

Seven Conductor Cable for ABS Power - Truck and Bus

2019-09-12
WIP
J2394
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8 2/10 4/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications. While the document’s title refers to ABS Power to differentiate the document from the SAE J1067 standard that it supersedes, the scope applies to both the primary green cable for powering ABS and lighting and the yellow auxiliary cable of the same construction.
Standard

Seven Conductor Cable for ABS Power - Truck and Bus

2017-12-20
CURRENT
J2394_201712
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-2/10-4/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications. While the document’s title refers to ABS Power to differentiate the document from the SAE J1067 standard that it supersedes, the scope applies to both the primary green cable for powering ABS and lighting and the yellow auxiliary cable of the same construction.
Standard

Seven Conductor Cable for ABS Power - Truck and Bus

2013-02-01
HISTORICAL
J2394_201302
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-2/10-4/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications. While the document’s title refers to ABS Power to differentiate the document from the SAE J1067 standard that it supersedes, the scope applies to both the primary green cable for powering ABS and lighting and the yellow auxiliary cable of the same construction.
Standard

Seven Conductor Cable - Truck and Bus

2019-09-12
WIP
J1067
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8 1/10 5/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications.
Standard

Seven Conductor Cable - Truck and Bus

2012-08-14
HISTORICAL
J1067_201208
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-1/10-5/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications.
Standard

Seven Conductor Cable - Truck and Bus

2007-06-12
HISTORICAL
J1067_200706
This SAE standard establishes the minimum construction and performance requirements for seven-conductor 1/8-1/10-5/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications.
Standard

Seven Conductor Cable - Truck and Bus

2016-10-25
CURRENT
J1067_201610
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-1/10-5/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications.
Standard

Recommended Practice for Identification of Standardized Truck and Tractor Electrical Circuits

2019-01-08
CURRENT
J2191_201901
This SAE document defines a recommended practice for implementing circuit identification for electrical power and signal distribution systems of the Class 8 trucks and tractors. This document provides a description of a supplemental circuit identifier that shall be utilized in conjunction with the original equipment manufacturer’s primary circuit identification as used in wire harnesses but does not include electrical or electronic devices which have pigtails. The supplemental circuit identifier is cross-referenced to a specified subsystem of the power and signal distribution system identified in Section 5.
Standard

Recommended Environmental Practices for Electronic Equipment Design in Heavy-Duty Vehicle Applications

2019-09-17
WIP
J1455
The scope of this Recommended Practice encompasses the range of environments which influence the performance and reliability of the electronic equipment designed for heavy duty on and off road vehicles, as well as any appropriate stationary applications which also use these vehicle derived components. A few examples of such vehicles are on and off highway trucks, trailers, buses, construction equipment, and agricultural equipment including implements.
Standard

Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design - Truck and Bus

2008-01-14
HISTORICAL
J2698_200801
1.1 This SAE Recommended Practice covers the design and application of primary on-board wiring distribution system harnessing for surface vehicles. This document is intended for single phase nominal 120 VAC circuits that provide power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off. The power supply comes from alternative sources such as land-based grid power, DC-AC inverters and auxiliary power generators. The circuits may also provide power to improve vehicle performance through charging batteries or operating cold-weather starting aids. 1.2 This document is not intended to provide guidance for electric or hybrid electric vehicle wiring circuits. Refer to SAE J1673 for high voltage automotive wiring assembly design. 1.3 Engine block heaters are 120 VAC devices that are used on a multitude of vehicle platforms in addition to trucks with sleeper cabs. Generally, the engine block heater circuit is wired independent of hotel loads.
Standard

Heavy-Duty Circuit Breakers

2013-05-03
CURRENT
J1625_201305
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for circuit breakers in ratings from 50 to 200 A. The document covers externally mounted automatic reset and manually reset types of circuit breakers for low voltage DC operation (typically 50 V or less).