Refine Your Search

Topic

Author

Search Results

Standard

Wrought and Cast Copper Alloys

2018-01-09
CURRENT
J461_201801
For convenience, this SAE Information Report is presented in two parts as shown below. To avoid repetition, however, data applicable to both wrought and cast alloys is included only in Part 1. Part I—Wrought Copper and Copper Alloys Types of Copper (Table 1) General Characteristics (Table 3) Electrical Conductivity Thermal Conductivity General Mechanical Properties (Table 10) Yield Strength Fatigue Strength Physical Properties (Table 2) General Fabricating Properties (Table 3) Formability Bending Hot Forming Machinability Joining Surface Finishing Color Corrosion Resistance Effect of Temperature Typical Uses (Table 3) Part II—Cast Copper Alloys Types of Casting Alloys Effects of Alloy Elements and Impurities General Characteristics (Table 11) Physical Properties (Table 12) Typical Uses (Table 11)
Standard

Wrought and Cast Copper Alloys

2002-12-20
HISTORICAL
J461_200212
For convenience, this SAE Information Report is presented in two parts as shown below. To avoid repetition, however, data applicable to both wrought and cast alloys is included only in Part 1. Part I—Wrought Copper and Copper Alloys Types of Copper (Table 1) General Characteristics (Table 3) Electrical Conductivity Thermal Conductivity General Mechanical Properties (Table 10) Yield Strength Fatigue Strength Physical Properties (Table 2) General Fabricating Properties (Table 3) Formability Bending Hot Forming Machinability Joining Surface Finishing Color Corrosion Resistance Effect of Temperature Typical Uses (Table 3) Part II—Cast Copper Alloys Types of Casting Alloys Effects of Alloy Elements and Impurities General Characteristics (Table 11) Physical Properties (Table 12) Typical Uses (Table 11)
Standard

Wrought Nickel and Nickel-Related Alloys

2018-02-15
CURRENT
J470_201802
This Report presents general information on over 50 alloys in which nickel either predominates or is a significant alloying element. It covers primarily wrought materials, and is not necessarily all inclusive. Values given are in most cases average or nominal, and if more precise values are required the producer(s) should be contacted. This report does not cover the so-called "superalloys," or the iron base stainless steels. Refer to SAE J467, Special Purpose Alloys, and SAE J405, Chemical Compositions of SAE Wrought Stainless Steels, respectively, for data on these alloys.
Standard

Wiring, Positioning, and Support Accessories

2010-05-12
HISTORICAL
AS23190A
AS23190 is a procurement specification that covers a series of plastic and metal components and devices used for the tying, positioning, and supporting cable, cable assemblies, wire, and wire bundles in electrical, electronic and communication equipment, and in interconnection systems.
Standard

Wiring, Positioning, and Support Accessories

2020-11-03
CURRENT
AS23190D
AS23190 is a procurement specification that covers a series of plastic and metal components and devices used for the tying, positioning, and supporting cable, cable assemblies, wire, and wire bundles in electrical, electronic, and communication equipment, and in interconnection systems.
Standard

Wiring Distribution Systems for Off-Road, Self-Propelled Work Machines

2010-05-11
HISTORICAL
J1614_201005
This SAE Standard specifies requirements and design guidelines for electrical wiring systems of less than 50 V and cable diameters from 0.8 to 19 mm2 used on off-road, self-propelled earthmoving machines as defined in SAE J1116 and agricultural tractors as defined in ASAE S390.
Standard

Wiring Distribution Systems for Off-Road, Self-Propelled Work Machines

2012-09-13
HISTORICAL
J1614_201209
This SAE Standard specifies requirements and design guidelines for electrical wiring systems of less than 50 V and cable diameters from 0.35 to 19 mm2 used on off-road, self-propelled earthmoving machines as defined in SAE J1116 and agricultural tractors as defined in ASAE S390.
Standard

Wiring Distribution Systems for Off-Road, Self-Propelled Work Machines

2018-11-21
CURRENT
J1614_201811
This SAE Standard specifies requirements and design guidelines for electrical wiring systems of less than 50 V and cable diameters from 0.35 to 19 mm2 used on off-road, self-propelled earthmoving machines as defined in SAE J1116 and agricultural tractors as defined in ASAE S390.
Standard

Wire, Electrical, Stranded, Uninsulated Copper, Copper Alloy, or Aluminum, or Thermocouple Extension, General Specification for

2020-09-01
HISTORICAL
AS29606A
This specification covers concentric lay stranded and rope-lay stranded round electrical conductor fabricated from copper, copper alloy or aluminum. This specification also covers thermocouple extension conductor fabricated from nickel/chromium or nickel/aluminum/manganese. The conductors in this specification are suitable for use in insulated wires used in aerospace and other applications.
Standard

Wire, Electrical, Stranded, Uninsulated Copper, Copper Alloy, or Aluminum, or Thermocouple Extension, General Specification For

2014-06-03
HISTORICAL
AS29606
This specification covers concentric lay stranded and rope-lay stranded round electrical conductor fabricated from copper, copper alloy or aluminum. This specification also covers thermocouple extension conductor fabricated from nickel/chromium or nickel/aluminum/manganese. The conductors in this specification are suitable for use in insulated wires used in aerospace and other applications.
Standard

Wire, Electrical, Solderless Wrap, Insulated and Uninsulated, General Specification For

2011-07-18
CURRENT
AS81822A
This specification covers both insulated and uninsulated solid conductor wire, designed for solderless wrap connections in electrical and electronic devices and equipment. The terminations of the wire are intended to be made with hand or automatic tools which wrap the wire, under tension, around terminal pins (commonly called wrapposts) to form solderless wrapped connections.
Standard

Wire, Electrical, Solderless Wrap, Insulated and Uninsulated, General Specification For

2004-06-22
HISTORICAL
AS81822
This specification covers both insulated and uninsulated solid conductor wire, designed for solderless wrap connections in electrical and electronic devices and equipment. The terminations of the wire are intended to be made with hand or automatic tools which wrap the wire, under tension, around terminal pins (commonly called wrapposts) to form solderless wrapped connections.
Standard

Wire, Electrical, Fluoropolymer-Insulated, Copper or Copper Alloy

2006-12-05
HISTORICAL
AS22759A
AS22759 specification covers fluoropolymer-insulated single conductor electrical wires made with tin-coated, silver-coated, or nickel-coated conductors of copper or copper alloy as specified in the applicable detail specification. The fluoropolymer insulation may be polytetrafluoroethylene (PTFE), fluorinated ethylene propylene (FEP), polyvinylidene fluoride (PVF2), ethylene-tetrafluoroethylene copolymer (ETFE), or other fluoropolymer resin. The fluoropolymer may be used alone or in combination with other insulation materials.
Standard

Wire, Electrical, Fluoropolymer-Insulated, Copper or Copper Alloy

2001-07-01
HISTORICAL
AS22759
This specification covers fluoropolymer-insulated single conductor electrical wires made with tin-coated, silver-coated, or nickel-coated conductors of copper or copper alloy as specified in the applicable specification sheet. The fluoropolymer insulation of these wires may be polytetrafluoroethylene (PTFE), fluorinated ethylene propylene (FEP), polyvinylidene fluoride (PVF2), ethylene-tetrafluoroethylene copolymer (ETFE), or other fluoropolymer resin. The fluoropolymer may be used alone or in combination with other insulation materials.
Standard

Wire, Electrical, Fluoropolymer-Insulated, Copper or Copper Alloy

2011-09-06
HISTORICAL
AS22759B
AS22759 specification covers fluoropolymer-insulated single conductor electrical wires made with tin-coated, silver-coated, or nickel-coated conductors of copper or copper alloy as specified in the applicable detail specification. The fluoropolymer insulation may be polytetrafluoroethylene (PTFE), fluorinated ethylene propylene (FEP), polyvinylidene fluoride (PVF2), ethylene-tetrafluoroethylene copolymer (ETFE), or other fluoropolymer resin. The fluoropolymer may be used alone or in combination with other insulation materials.
Standard

Wire, Electrical, Crosslinked Polyalkene, Crosslinked Alkane-Imide Polymer, or Polyarylene Insulated, Copper or Copper Alloy

2019-07-08
CURRENT
AS81044B
AS81044 covers single conductor electric wires made as specified in the applicable detail specification with tin-coated, silver-coated, or nickel-coated copper or copper alloy conductors insulated with crosslinked polyalkene, crosslinked alkane-imide polymer, or polyarylene. The crosslinked polyalkene, crosslinked alkane-imide polymer, or polyarylene may be used alone or in combination with other insulation materials as specified in the detail specification.
X