Technical Paper

Electromechanical Actuator Cooling Fan Reliability Analysis and Safety Improvement

2016-09-20
2016-01-1997
The aircraft electromechanical actuator (EMA) cooling fan is a critical component because an EMA failure caused by overheating could lead to a catastrophic failure in aircraft. Fault tree analysis (FTA) is used to access the failure probability of EMA fans with the goal of improving their mean time to failure (MTTF) from ∼O(5×104) to ∼ O(2.5×109) hours without incurring heavy weight penalty and high cost. The dual-winding and dual-bearing approaches are analyzed and a contra rotating dual-fan design is proposed. Fan motors are assumed to be brushless direct current (BLDC) motors. To have a full understanding of fan reliability, all possible failure mechanisms and failure modes are taken into account. After summarizing the possible failure causes and failure modes of BLDC fans by focusing on each failure mechanism, the life expectancy of fan ball bearings based on a major failure mechanism of lubricant deterioration is calculated and compared to that provided in the literature.