Technical Paper

ECS Re-Test Analytical Evaluation

2005-07-11
2005-01-3118
A final test activity was carried out to complete the verification of the Environmental Control System (ECS) performances by experimentally reproducing the thermal hydraulic behaviour of the Environmental Control & Life Support Subsystem (ECLSS) section integrated in the overall Module, expected on analytical basis. A previous test campaign (called Columbus ECS PFM Test) carried out in EADS-Bremen in spring 2003 and described in paper number 2004-01-2425 showed some contradictory data concerning the air loop behaviour. These incoherent test results were related to the environmental and geometrical cabin loop conditions during the on-ground 1g test and to improper position of the sensor measuring the cabin temperature. For this reason a partial repetition of the test has been performed. In particular, this experimental campaign was focused on the verification of the cabin air temperature control, as a consequence of the Temperature Control Valve (TCV) movement.
Technical Paper

Columbus to Human Research Facility Hydraulic Compatibility Test: Analysis and Results

2005-07-11
2005-01-3119
ESA and NASA agencies agreed to run an interface compatibility test at the EADS facility between the Columbus flight module and a duplicate ground unit of a currently on-orbit US International Standard Payload Rack, the Human Research Facility (HRF) Flight Prototype Rack (FPR). The purpose of the test was to demonstrate the capability to run US payloads inside the European ISS module Columbus. One of the critical aspects to be verified to ensure suitable operations of the two systems was the combined performance of the hydraulic controls resident in the HRF and Columbus coolant loops. A hydraulic model of the HRF FPR was developed and combined with the Columbus Active Thermal Control System (ATCS) model. Several coupled thermal-hydraulic test cases were then performed, preceded by mathematical analysis, required to predict safe test conditions and to optimize the Columbus valve configurations.
Technical Paper

Columbus Integrated System Level ECS Test Correlation

2004-07-19
2004-01-2425
The Columbus ECS PFM Test was intended as the final verification of the Module Thermal Design after a series of successful tests at subsystems level (e.g. the Active Thermal Control Subsystem and the Environmental Control and Life Support System) The test campaign has been articulated as a sequence of several test cases to investigate the main thermal aspects, to prove the Module thermal design in the extreme operative conditions and to correlate the thermal mathematical model (TMM). The interpretation of test results and the correlation confirmed that the thermal design of the module is adequate, but some areas of concern remain, mainly for the difficulty to translate to 0-g the results of a complex test in 1-g environment, and for some aspects of the air and cabin loops.
Technical Paper

Columbus Active Thermal Control Equipment Development

2005-07-11
2005-01-2769
The Columbus laboratory module for the International Space Station (ISS) uses active thermal control for cooling of avionics and payload in the pressurized compartment. The Active Thermal Control Subsystem (ATCS) is based on a water loop rejecting waste heat to the Medium Temperature Heat Exchanger and Low Temperature Heat Exchanger on Node 2, part of the US Segment of the ISS. Flow and temperature control in the ATCS is achieved by means of the Water Pump Assembly (WPA) and the 3-Way Modulating Valve (WTMO) units. For the flow control the WPA speed is commanded so that a fixed pressure drop is maintained over the plenum with the avionics and payload branches. Adjusting the WTMO internal flow split permit the two active units to perform the CHX and plenum inlet temperature control. The WPA includes a filter and an accumulator to control the pressure in the ATCS and to compensate for leakage and temperature-dependent volume variations.