Refine Your Search

Search Results

Viewing 1 of 1
Technical Paper

Advanced Temperature Control in Aircraft Cabins - A Digital Prototype

2017-09-19
2017-01-2161
For thermal cabin control of commercial aircraft, the cabin is usually divided into a small number of temperature zones. Each zone features its own air supply pipe. The necessary installation space for ducting increases significantly with the number of zones. This requires the number of temperature zones to be low. Factors such as seating layout, galley placement and passenger density result in deviations in heat flux throughout the cabin. These deviations cannot be compensated by the control system, if they occur within the same temperature zone. This work presents a novel temperature regulation concept based on local mixing. In this concept, two main ducts span the complete cabin length, and provide moderately warm and cold air. At each temperature zone, cabin supply air is locally mixed using butterfly valves. In this way, the number of temperature zones can be individually scaled up without any additional ducting, only requiring additional valves for each temperature zone.
X