Refine Your Search

Topic

Search Results

Standard

Useful Life Determination for Chemical Oxygen Generators

2013-12-13
HISTORICAL
ARP1894A
The scope of this document is to provide a guideline for the preparation of a plan for testing of inservice chemical oxygen generators to confirm their design useful life. The test program should also allow determination with a sufficient level of confidence, whether generators are suitable for further use (i.e., life extension, or if the useful life limit has been reached).
Standard

Useful Life Determination for Chemical Oxygen Generators

2014-02-13
CURRENT
ARP1894B
The scope of this document is to provide a guideline for the preparation of a plan for testing of inservice chemical oxygen generators to confirm their design useful life. The test program should also allow determination with a sufficient level of confidence, whether generators are suitable for further use (i.e., life extension, or if the useful life limit has been reached).
Standard

USEFUL LIFE DETERMINATION CHEMICAL OXYGEN GENERATORS

1987-02-01
HISTORICAL
ARP1894
This document provides recommended guidelines for a comprehensive program to determine the useful life of chemical oxygen generators where useful life is defined as the sum of shelf and service life. Further, this document provides for a test program to determine with a sufficient level of confidence if the generators are suitable for further use and/or if the life limit has been reached. This program should include testing of generators of a representative sampling of a given year's production, of a particular part number, to provide a level of confidence sufficient to permit the units to be used for an additional specified time period.
Standard

Transfilling and Maintenance of Oxygen Cylinders

2008-11-17
HISTORICAL
AIR1059B
The purpose of this document is to list the best available information and guidelines for the qualification of personnel who are responsible for the filling of fixed or portable aircraft oxygen cylinders.
Standard

STANDARD FOR OXYGEN FLOW INDICATORS

1966-07-01
HISTORICAL
AS916
This standard is intended to establish general material and design requirements for oxygen flow indicating devices. Flow indicators considered are for diluter-demand and continuous flow systems.
Standard

Reducers, Oxygen Pressure

2023-01-26
CURRENT
AS17852A
This specification covers the requirements for two types of oxygen pressure reducers.
Standard

Reducers, Oxygen Pressure

2009-11-30
HISTORICAL
AS17852
This specification covers the requirements for two types of oxygen pressure reducers.
Standard

Oxygen Mask Assembly, Demand and Pressure Breathing, Crew

2014-10-16
CURRENT
AS452B
This standard covers both general type and quick-donning type mask assemblies in the following classes: a Class A, oronasal, demand b Class B, oronasal, pressure-demand c Class C, full face, demand d Class D, full face, pressure-demand
Standard

Oxygen Mask Assembly, Demand and Pressure Breathing, Crew

2003-10-15
HISTORICAL
AS452A
This standard covers both general type and quick-donning type mask assemblies in the following classes: a Class A, oronasal, demand b Class B, oronasal, pressure-demand c Class C, full face, demand d Class D, full face, pressure-demand
Standard

Oxygen Flow Indication

2019-01-10
CURRENT
AS916C
This SAE Aerospace Standard (AS) defines the overall requirements applicable to oxygen flow indication as required by Airworthiness Requirements of CS/FAR 25.1449 to show that oxygen is being delivered to the dispensing equipment. Requirements of this document shall be applicable to any type of oxygen system technology and encompass “traditional” pneumatic devices, as well electric/electronic indication.
Standard

Minimum Standards for Valve, High Pressure Oxygen, Line Shut Off, Manually Operated

2004-06-23
HISTORICAL
AS1214A
This standard covers all types of manually operated high pressure oxygen line shut off valves utilizing either metallic or nonmetallic valve seats for use in general and commercial type aircraft. It is intended that the line valve should be installed in a position accessible in flight, when the cylinder mounted oxygen valves are not. The line shutoff valve may also be used optionally in large systems as a maintenance aid where only a portion of the system need be opened up and purged after repair or replacement of one or more parts.
Standard

Minimum Standards for Valve, High Pressure Oxygen, Cylinder Shut Off, Manually Operated

2023-04-26
CURRENT
AS1066B
This standard covers all types of manually operated high pressure oxygen, cylinder shut off valves for use in commercial aircraft. It is intended that the valve shall be attached to a pressure cylinder storing oxygen under a nominal pressure of 12.76 MPa (1850 psig) at 21 °C (70 °F). Upon opening the valve, oxygen will be permitted to discharge from the storage cylinder to the valve outlet and to other downstream components of the oxygen system. It shall also be possible to recharge the cylinder through the valve.
X