Wiring Aerospace Vehicle

2013-12-09
HISTORICAL
AS50881E
This specification covers all aspects in electrical wire interconnection systems (EWIS) from the selection through installation of wiring and wiring devices and optical cabling and termination devices used in aerospace vehicles. Aerospace vehicles include manned and unmanned airplanes, helicopters, lighter-than- air vehicles, missiles and external pods.
Standard

Wiring Aerospace Vehicle

2019-08-06
HISTORICAL
AS50881G
This specification covers all aspects in Electrical Wiring Interconnection Systems (EWIS) from the selection through installation of wiring and wiring devices and optical cabling and termination devices used in aerospace vehicles. Aerospace vehicles include manned and unmanned airplanes, helicopters, lighter-than-air vehicles, missiles, and external pods.
Standard

Wiring Aerospace Vehicle

2015-05-29
HISTORICAL
AS50881F
This specification covers all aspects in electrical wire interconnection systems (EWIS) from the selection through installation of wiring and wiring devices and optical cabling and termination devices used in aerospace vehicles. Aerospace vehicles include manned and unmanned airplanes, helicopters, lighter-than-air vehicles, missiles and external pods.
Standard

Transmission Lines, Transverse Electromagnetic Mode

2016-01-09
HISTORICAL
ARP81490A
This document covers the general recommendations for Transverse Electromagnetic Mode (TEM) Transmission Lines intended for use in airborne systems (see 6.2.14). For U.S military applications, TEM Transmission Lines shall meet the requirements in accordance with MIL-T-81490. The follow index lists the recommended requirements and methods covered by the Aerospace Recommended Practice (ARP):
Standard

Transmission Lines, Transverse Electromagnetic Mode

2020-10-30
CURRENT
ARP81490B
This document covers the general recommendations for Transverse Electromagnetic Mode (TEM) Transmission Lines intended for use in airborne systems (see 6.2.14). For U.S military applications, TEM Transmission Lines shall meet the requirements in accordance with MIL-T-81490. The follow index lists the recommended requirements and methods covered by the Aerospace Recommended Practice (ARP):
Standard

Recommended Test Fluids for Electrical Components Used on Aircraft Exterior or for Ground Support Near Aircraft

2007-02-16
HISTORICAL
ARP5062
The purpose of this SAE Aerospace Recommended Practice (ARP) is to provide recommended test fluids for testing of electrical components used on aircraft exterior or for ground support near aircraft. These fluids were selected based on a consolidation of test fluids used by military and commercial sources and on review of national and international component specifications. These recommendations are general guidelines. Safety factors for any unusual testing applications or operating conditions should be given special consideration by the designer. The test fluids provided are intended to be recommendations and are not intended to limit or supersede those recommended by aircraft or ground support equipment manufacturers.
Standard

Recommended Test Fluids for Electrical Components Used on Aircraft Exterior or for Ground Support Near Aircraft

2012-11-21
CURRENT
ARP5062A
The purpose of this SAE Aerospace Recommended Practice (ARP) is to provide recommended test fluids for testing of electrical components used on aircraft exterior or for ground support near aircraft. These fluids were selected based on a consolidation of test fluids used by military and commercial sources and on review of national and international component specifications. These recommendations are general guidelines. Safety factors for any unusual testing applications or operating conditions should be given special consideration by the designer. The test fluids provided are intended to be recommendations and are not intended to limit or supersede those recommended by aircraft or ground support equipment manufacturers.
Standard

Hot Stamp Wire Marking Concerns for Aerospace Vehicle Applications

2017-01-24
CURRENT
AIR5575A
This SAE Aerospace Information Report (AIR) discusses the often overlooked relationship between hot stamp marking and the environmental conditions that contribute aircraft wiring problems and discusses current beliefs of military service experts, regulatory agencies and industry standard writing bodies about the potential hazards imposed by the hot stamping process.
Standard

Hot Stamp Wire Marking Concerns for Aerospace Vehicle Applications

2009-01-15
HISTORICAL
AIR5575
This SAE Aerospace Information Report (AIR) discusses the often overlooked relationship between hot stamp marking and the environmental conditions that contribute aircraft wiring problems and discusses current beliefs of military service experts, regulatory agencies and industry standard writing bodies about the potential hazards imposed by the hot stamping process.
Standard

Electrical Wiring Fuel Compatibility

2018-12-12
HISTORICAL
AIR6820
This SAE Aerospace Information Report (AIR) is limited to the subject of compatibility of wiring as part of aircraft Electrical Wiring and Interconnect Systems (EWIS) installed in and around aircraft fuel tanks.
Standard

Electrical Wiring Fuel Compatibility

2020-09-18
CURRENT
AIR6820A
This SAE Aerospace Information Report (AIR) is limited to the subject of compatibility of wiring as part of aircraft Electrical Wiring and Interconnect Systems (EWIS) installed in and around aircraft fuel tanks.
Standard

Development, Verification, and Validation of a Thermal Model for Determining Current Derating Design Limits of Aerospace Wires and Wire Bundles

2021-08-18
CURRENT
ARP7987
The thermal modeling guidelines and best practices provided in this document are applicable to powered aerospace vehicle wires and wire bundles in thermal environments ranging from -65 to +260 °C (-85 to +500 °F) and pressures ranging from sea level to space vacuum. Currently the ARP only considers steady state and direct current conditions. The effects of wiring terminations and connectors are not addressed. Both can significantly impact the overall current derating and safety margins for a wiring system.